3B BASICBilly Manuale utente

P72
(1012793)

2

®
3
English .......................................................................................................... 4
Deutsch ......................................................................................................... 8
Español ....................................................................................................... 12
Français ...................................................................................................... 16
Português .................................................................................................... 20
Italiano ....................................................................................................... 24
Japa ........................................................................................................... 28
Русский ..................................................................................................... 32
中文 ........................................................................................................... 36
Türkçe ......................................................................................................... 40
................................................................................................................... 44

®
4
English
BLS-Simulator BASICBilly™
1 BASICBilly™consists of 4
2 Assembly 5
2.1 Changing the springs 5
2.2 Changing the air bag 6
3 Cleaning and care 6
4 Possible exercises 7
5 Product information 7
6 Guarantee and Certifications 7
7 Consumables, accessories and replacement parts 7
BASICBilly™is a Cardiopulmonary Resuscitation (CPR) training model for the education of the general
population. The simulator is compliant with the last CPR guidelines (AHA and ERC). Thanks to its robust
construction, its ease of use and its realistic handling, it is suitable for both medical training and for tea-
ching in schools, clubs and for first aid courses.
It offers all the necessary features to learn about the life-saving algorithm, comprising cardiac massage and
respiration for adults and children. Its features are:
• Torsowithshouldersandthenecessaryanatomicalfeaturestofindtheidealpressurepointforcardiac
massage
• Headwithairwaysformouth-to-mouthandmouth-to-noserespiration
• Headtilttoopentheairways
• Maskventilationisalsopossible
• Realisticthoracicspringforceandtherequiredcompressiondepthof5cmpreparethetraineeforthe
situation with a real person
• Usingtwospringswithdifferinglevelsofspringforcetodemonstratealgorithmsforbothadultsand
children
• Asoundindicatesthattherequiredcompressiondepthhasbeenreached
• Low-priceddisposableairwaysensurehygienicuseandeasycareofthemannequin
• TheplasticsusedmeettheDINEN71-3/9ToySafetyDirective
• BASICBilly™is developed and manufactured in Germany
1 BASICBilly™ consists of
Basic body with removable thorax
2 Springs(red=adult;green=child)
1 Telescopic guide
1 Face skin
1 Thorax skin
1 Head with skin cover, air bag holder and air bags
2 Aditional face skins
2 Aditional mouth pieces incl. air bag holder
50 Disposableairways
1 Disinfectant

®®
English
5
EnglishEnglish
2 Assembly
2.1 Changing the springs
BASICBilly™can be used in adult or in child mode. To do this, adjust the springs to alter the thorax
resistance for cardiac massage, and change the air bags for artificial respiration.
• PlacetheBASICBilly™on a flat, even surface
• Firstofall,removethefaceskinbyreleasingthefourattachments.Todothis,pulldownonthebut-
ton tabs on the skin at the designated points:
BLS-Simulator BASICBilly™
1
1
2
2
3
3
4
4
• Dothesameforthetorsoskin
• Oncethepressstudsplacedaroundthewhitethoraxhavebeenundoneyoucanremovetheskin.
• Placethesprings(red=adult;green=child)intotheholderandfitthetelescopicguide(redpoint=
adult;greenpoint=child);
• Toassemblethetorso,dotheaboveinreverseorder.Toputonthethorax,firstofalltiltthehead
back and push the neck piece of the thorax forward before fixing it in place.

®
English
6
BLS-Simulator BASICBilly™
2.2 Changing the air bag
• PlacetheBASICBilly™on a flat, even surface
• Removethefaceskinfirstofallbyreleasingthefourattachments.Todothis,pulldownonthebutton
tabs on the skin at the designated points:
• Dothesameforthetorsoskin
Magnets
• Removethemouthpiecethatisattachedwithmagnetsandtakeoffthelungbagholderinside
• Now,pickuponeofthelungbagsprovided
• Pushtheupperendofthelungbag(startofthesimulatedtrachea)overtheroundopeningofthelung
bag holder
• Slidethisintotheguiderailontheheadandspreadoutthelungbagflatonthethorax,ensuringthat
it does not become creased while you are putting together the simulator
• Placethemouthpieceontothelungbagholder
• Thenattachthetorsoskin,followedbythefacemask,withthebuttontabs(seeabove)
3 Cleaning and care
All parts that come into contact with the breath, such as the face mask, inner head cover and the lung
bag holder can be disinfected with the disinfectant supplied.

®
English
7
BLS-Simulator BASICBilly™
The disposable airways (lung bags) also ensure that the simulator is particularly hygienic to use. The disin-
fectant provided has been tested with the simulator material. To prevent the parts to be disinfected beco-
mingdamaged,werecommendusingthetestedproduct(#1013579).
4 Possible exercises
• Freeinguptheairways
Head tilt to open the airways.
• Findingthecompressionpoint
Realistic anatomical characteristics ensure that the correct compression point can be easily found.
• Compressiondepth
AsoundindicatesthattherequiredcompressiondepthhasbeenreachedThisvariesaccordingto
whichspringhasbeenchosen(red=adult;green=child)
• Respiration
Respiration can be carried out as mouth to mouth, mouth to nose, or using the mask (see chapter
Accessories and Replacement Parts).
If done correctly, the skin on the thorax will rise visibly
5 Product information
Size: L59xH15xW32
Weight:2.4kg
Avoid storing the device in direct sunlight.
6 Guarantee and Certifications
3 year guarantee, but not for consumables and worn parts.
7 Consumables, accessories and replacement parts
Product Article no
Components
Quantity
per Set
Lungbags,
Adult 1013573* 25
Lungbags,
Child 1013576* 25
Spring340N(red),
Adult 1013577* 1
Spring280N(green),
Child 1013578* 1
Resuscitator with
1disposableFaceMask 1013678 1
DisposableFaceMasks 1013677 5
Disinfectant-
40 gr. bags 1013579* 5
Face skin 1013582* 5
Jaw insert 1013584* 5
LungBagSocket 1013585* 5
ThoraxSkin 1013587* 1
*Includedinthisdelivery(quantityseechap.1).

®
Deutsch
8
BLS-Simulator BASICBilly™
1 BASICBilly™bestehtaus 8
2 Montage 9
2.1 AuswechselnderFedern 9
2.2 AuswechselndesLuftbeutels 10
3 Reinigung und Pflege 10
4 Übungsmöglichkeiten 11
5 Produktdaten 11
6 GarantieundZertifizierungen 11
7 Verbrauchsmaterial, ZubehörundErsatzteile 11
BASICBilly™isteinÜbungsmodellfürdieHerz-Lungenwiederbelebung(CPR)inderLaienausbildung.Der
SimulatorerfülltdieneustenRichtlinienzurCPR(AHAundERC).DankseinerrobustenBauweise,seiner
einfachenBedienbarkeitundderrealistischenAnwendungeignetersichsowohlfürdiemedizinische
AusbildungalsauchfürdieBreitenausbildunginSchulen,VereinenundErste-Hilfe-Kursen.
Er bietet alle geforderten Eigenschaften, die es erlauben, den lebensnotwendigen Algorithmus aus
HerzdruckmassageundBeatmungamErwachsenenoderKindeinzustudieren.SeineMerkmalesind:
• TorsomitSchulternundnotwendigenanatomischenMerkmalenzumAuffindendesidealen
DruckpunktesfürdieHerzdruckmassage
• KopfmitAtemwegenfüreineMund-zu-Mund-undMund-zu-Nase-Beatmung
• ÜberstreckendesKopfeszumFreimachenderAtemwege
• AuchdieMaskenbeatmungistmöglich
• RealistischeRückstellkräftedesBrustkorbesundeinenachdenLeitliniengeforderteEindrucktiefevon
5cmbereitendenÜbendenaufdieSituationamMenschenvor
• MittelszweierFedernverschiedeneRückstellkräftefürdieDarstellungamErwachsenenoderamKind
• AkustischesSignalbeiErreichendergefordertenEindrucktiefe
• PreisgünstigeEinweg-AtemwegesorgenfürhygienischeAnwendungsowieeinebequemeReinigung
und Pflege der Puppe
• dieverwandtenKunststoffeentsprechenderSpielzeugrichtlinieDINEN71-3/9
• BASICBilly™istinDeutschlandentwickeltundhergestelltworden
1 BASICBilly™ besteht aus
1 Grundkorpus mit abnehmbarem Brustkorb
2 Federn(rot=Erwachsene;grün=Kind)
1 Teleskopführung
1 Gesichtshaut
1 Thoraxhaut
1 Mundstück(Kopfkernoberseiteund-deckel)inkl.LuftbeutelhalterundLuftbeutel
2 Gesichtshäute
2 Mundstückeinkl.Luftbeutelhalter
50 Einweg-Atemwege
1 Desinfektionsmittel

®
9
Deutsch
2 Montage
2.1 Auswechseln der Federn
BASICBilly™kannimErwachsenenmodusoderimKindermodusgenutztwerden.Hierzusinddie
FedernfürdenThoraxwiderstandbeiderHerzdruckmassageunddieLungenbeutelbeimBeatmen
anzupassen.
• LegensiedafürBASICBilly™aufeinegerade,ebeneUnterlage
• EntfernensiezunächstdieGesichtshautdurchLösendervierBefestigungspunkte,indemdieHautent-
sprechendderKnopf-ÖsenkonstruktionandengenanntenPunktennachuntengezogenwird:
BLS-Simulator BASICBilly™
1
1
2
2
3
3
4
4
• GleicheserfolgtnunmitderTorsohaut
• NachÖffnenderrundumdenweißenBrustkorbangeordnetenDruckknopfverbindungenkönnenSie
diesen abheben.
• LegenSiedieFeder(rot=Erwachsene;grün=Kind)indieHalterungundsetzendiezugehörige
Teleskopführung(roterPunkt=Erwachsene;grünerPunkt=Kind)auf.
• ZumZusammensetzengehensieinumgekehrterReihenfolgevor.ZumAufsetzendesBrustkorbes
überstreckensiezunächstdenKopfundschiebendasHalsstückdesBrustkorbsvorbevorsiediesen
arretieren.

®
Deutsch
10
BLS-Simulator BASICBilly™
2.2 Auswechseln des Luftbeutels
• LegensiedafürBASICBilly™aufeinegerade,ebeneUnterlage
• EntfernensiezunächstdieGesichtshautdurchLösendervierBefestigungspunkte,indemdieHautent-
sprechendderKnopf-ÖsenkonstruktionandengenanntenPunktennachuntengezogenwird:
Magnete
• GleicheserfolgtnunmitderTorsohaut
• EntnehmenSiedasmitMagnetenfixierteMundstückundziehendeninnenseitiggelegenen
Lungenbeutelhalterab
• NehmenSienuneinenderbeigefügtenLungenbeutelzurHand.
• SchiebenSiedasobereEndedesLungenbeutels(BeginndersimuliertenLuftröhre)überdierunde
ÖffnungdesLungenbeutelhalters.
• LegenSiediesenindieFührungsschieneamKopfteilundbreitendenLungenbeutelflachaufdem
Brustkorbaus,achtenSiedarauf,dasserbeimZusammensetzendesSimulatorsknickfreiverbleibt.
• SetzenSiedasMundstückaufdenLungenbeutelhalter.
• AbschließendbefestigenSiezunächstdieTorsohaut,danndieGesichtsmaskeentsprechendeihrer
Knopf-Ösenkonstruktion(sieheoben).
3 Reinigung und Pflege
AlleTeile,diemitAtemstrominKontaktkommenwieGesichtshaut,Mundstückund
Lungenbeutelhalter,könnenmitdembeigefügtenDesinfektionsmitteldesinfiziertwerden.Die
Einweg-Atemwege(Lungenbeutel)sorgenzudemfüreinebesondershygienischeAnwendung.
Indice
Lingue:
Altri manuali 3B Prodotto didattico scientifico