4Ddoors 4DR1 v4 Guida rapida

4DOMU01A-2
Installation instructions and Owner's manual
Roller door operator
4DR1 v4
READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION
Installer: Permanently attach manual to the wall.

Inventory
Operator Unit
Anti-Coning Clip x2 sets
Weight Bar & mounting screw set x1
Wireless Wall Button x1 *
U-bolt + Saddle x1 set
Manual + Safety Label
Remote Handset x2 *
2
* Optional Accessories
* Items and quantity may differ to images shown

3
Electrical Rating
Input AC 220V 50/60Hz
Max. Current 2A
Power 100W
Standby Power <2W
Motor
Type DC 24V
Max. Capacity 1000N
Recommended Lifting Forces
Max. Lifting Force 60kg
Rated Lifting Force 40kg
Door Type
Max. Door Size 20.5m2
Max. Door Height 4.6m
Door Travel Limits 4.5 turns of door drum approx.
Courtesy Light
Light Source 6 x Ultra Bright LEDs
Lighting Time 2.5 minutes
Transmitter
Frequency 433MHz
Operation Range 50m (open field)
Coding Type Fixed-code
Battery 12V (A23 Alkaline) x 1
Features
Soft opening and closing
Safety reverse on closing and stop on opening
Digital interface for RH/LH setting, force adjustment, etc.
Miscellaneous
Operating Temperature -20oC ~ +50oC
Dimension (mm) 434 L x 248 W x 190H
Weight 5.4kg approx.
SPECIFICATION

4
PRE-INSTALLATION NOTES
Ensure there is a properly earthed mains supply socket adjacent to where the operator is to be fit-
ted.
If the operator is being fitted at the same time as the new door installation, read these instructions in
conjunction with the door installation instructions.
If the operator is being retro-fitted, make sure the door operates smoothly and is properly balanced.
N.B.: SPECIAL CARE SHOULD BE TAKEN IF RE-TENSIONING OF THE DOOR IS REQUIRED.
Door Type Minimum side clearance
“A” Series ( 25mm deep tracks ) 90mm
“AA” Series (50mm deep tracks ) 115mm
All doors with Windlok Tracks subject to Drum Position 140mm
Pre-Installation Notes 4
Important Notices 5
Installation Instructions 6
Connectors 7
Setting Direction of Operation 8
Setting UP-Limit 9
Setting DOWN-Limit 10
Sensitivity Auto-Learning 11
Manual Sensitivity Adjustment (For Installers Only) 12
Programming Transmitter 13
Setting Auto-Closing Timer 14
Trouble-Shooting 15
Parts Breakdown 16
Parts List 17
Warranty 18
The operator may be fitted to either the RIGHT or LEFT hand side of the roller door.
Check that there is sufficient side clearance to fit the operator unit as below listed:
TABLE OF CONTENTS

5
IMPORTANT : PLEASE READ THESE INSTRUCTIONS CAREFULLY PRIOR TO
COMMENCING THE INSTALLATION OF THE OPERATOR UNIT.
This Automatic Operator has been designed to provide years of trouble-free
use.
READ THESE IMPORTANT SAFETY RULES FIRST
Keep the garage door balanced. Sticking or binding doors must be repaired.
Garage door, door springs, brackets and their hardware are under extreme
tension and can cause serious personal injury. Do not attempt adjustment. Call
for professional garage door service .
Do not wear rings, watches or loose clothing while installing or servicing a garage
door operator.
Installation and wiring must be in compliance with your local building and
electrical codes. Connect the power cord only to properly earthed mains.
The safety reverse system test is very important. Your garage door must
reverse when obstructed on closing. Failure to properly adjust the operator may
result in serious personal injury from a closing garage door. Repeat the test once
a month and make any needed adjustments. (See Sensitivity adjustment).
This unit should not be installed in a damp or wet space.
Pull down on the Emergency Release handle to disengage the motor drive ONLY
when the drive is switched OFF and, if possible, when the door is fully closed.
Do not use the sensitivity adjustments to compensate for a binding or sticking
garage door. Excessive sensitivity will interfere with the proper operation of the
Safety Reverse System or damage the garage door.
Disengage all existing garage door locks to avoid damage to garage door.
Install any additional Push Buttons in a location where the garage door is visible,
but out of the reach of children. Do not allow children to operate push button/s or
remote control/s. Serious personal injury from a closing garage door may result
from misuse of the operator.
CAUTION: Activate operator only when the door is in full view, free of
obstructions and the operator is properly adjusted. No one should enter or leave
the garage while the door is in motion. Do not allow children to play near the door.
Disconnect electric power to the garage door operator before making repairs or
removing covers.
IMPORTANT: Fix the caution label supplied to the rear of the garage door as
a reminder of safe operating procedures.
NOTE: 1. When you disengage the unit, please move the door gently.
2. Direction of operation (L/R) must be set correctly before operation.
CAUTION
!
!
CAUTION
!
CAUTION
DANGER
DANGER
IF THERE IS ANY PROBLEM PLEASE CONTACT YOUR LOCAL
SUPPLIER OF THIS OPERATOR
IMPORTANT NOTICES

6
1. Fit anti-coning collar TIGHT TO SHAFT against drum at
opposite end of curtain to the motor using anti-coning clip
supplied in kit as shown in Fig.1.
2. Left off about pinning the curtain to the drum wheel.
Ensure the curtain is pinned to the drum wheel.
3. Roll up door with at least 100mm of curtain hanging down
in the tracks.
4. Ensure that the U-bolt on the end of the door opposite the
end to which the operator is to be fitted is tightened
securely. This U-bolt holds all the spring tension on the
door once the other U-bolt is released.
5. Slide drive unit onto shaft as shown in Fig.2. Ensure the
drive forks engage fully with the narrowest spoke on drum
wheel.
6. For ease of installation, the sun gear can be disengaged
for free rotation by pulling the Emergency Release handle
downwards. To re-engage and lock the sun gear, pull down
on the handle once again until a "click" is heard.
Caution : Operator must be ENGAGED before
proceeding further installation.
Fig.1
Engage - Pull down the release cord firmly with 'click'
(handle is on same level as bottom of the operator)
Disengage - Pull down the release cord firmly with 'click'
(handle is below the bottom of the operator)
Emergency Release
Fig.2
INSTALLATION INSTRUCTIONS

7
CONNECTORS
OFF 2.5 min
_+
Backup Bat-
LED Light
Auto-Close Timer
II. Miscellaneous Control and Terminals
* Auto Close Timer function will only work when Photo Eye System is properly installed.
!WARNING : This operator system is equipped with an unattended operation feature
when Photo Eye System is applied. The door could move unexpectedly.
NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR!
To activate Auto-Close Operation Turn the knob towards “ + ” for maximum delay time of
2.5 minutes.
To deactivate Auto-Close Operation Turn the knob fully towards “- ”.
Photo Eye Selection
Jumper off — Selected
Jumper on — Unselected Push Button
DC 24V
Ext. Aerial
GND
Photo Eye
UP RADIO SET FORCE
Manual Operate
Button
I. Main Control Panel
LED Indicators

8
UP RADIO SET FORCE
UP RADIO SET FORCE
For using the operator the first time, it is necessary to set the direction of
operation.
1. Connect power supply, both “UP” and “DOWN” LEDs are on.
3. Press “RADIO SET” button to confirm setting. The “OK” LED is on with 2 beeps.
2. Initialize the operational direction by pressing “UP” or “DOWN” button for the
correct direction setting according to the illustrations below. The correspond-
ing LED is on upon key input.
Caution : Make sure the drive unit is set for the correct side of installation!
To reset installation direction, press the “LIMIT” button constantly until both “UP”
and “DOWN” LEDs are ON, repeat steps 2 and 3 to set the appropriate direction.
x2
Indoor view Indoor view
SETTING DIRECTION OF OPERATION
UP RADIO SET FORCE

9
UP RADIO SET FORCE
UP RADIO SET FORCE
1. Press “LIMIT” button once to enter limit-setting mode. “UP” LED is on.
2. Press & hold the “UP” button, release the “UP” button when the door reaches
the desired up limit position.
3. During limit-setting mode, press “UP” or “DOWN” to fine-tune to desired UP
limit position.
4. When the door is at the desired UP limit position, press “LIMIT” button once,
“OK” LED flashes and goes out. UP limit is set.
or
SETTING UP LIMIT
UP RADIO SET FORCE
UP RADIO SET FORCE

10
UP RADIO SET FORCE
UP RADIO SET FORCE
UP RADIO SET FORCE
UP RADIO SET FORCE
1. Press “LIMIT” button twice to enter DOWN-limit setting. “DOWN” LED is on.
2. Press & hold the “DOWN” button, release the “DOWN” button when the door
reaches the desired down limit position.
3. During limit-setting mode, press “UP” or “DOWN” to fine-tune to desired down
limit position.
4. When the door is at the desired DOWN limit position, press “LIMIT” button
once, “OK” LED flashes twice and both “UP” and “DOWN” LEDs are on.
DOWN limit is set and the operator is ready for Sensitivity Auto-Learning.
or
SETTING DOWN LIMIT
Indice
Altri manuali 4Ddoors Sistema di apertura della porta