AAT KaDe KDH-KZ2000-IP-U Manuale utente

Integrated Access Controller – Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved. 1
Installaon Manual
INTEGRATED ACCESS CONTROLLER
KDH-KZ2000-IP-U
KDH-KZ2000-IP-M
VERSION 1.0
Installaon Manual
INTEGRATED ACCESS CONTROLLER
KDH-KZ2000-IP-U
KDH-KZ2000-IP-M
VERSION 3.0 25-06-2020

Integrated Access Controller – Installation manual
2 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
1. Introduction …………..…………..…………..…………..…………..……………….. 3
2. Controller technical data …………..…………..…………..…………..…….…. 4
3. Controller wiring diagram …………..…………….………………..……………. 6
4. Controller installation …………..…………..…………..…………..…………….. 9
5. Management in standalone mode ………….…………..…………..……... 10
6. Programming codes table …………..…………………...…..…………..…... 14
7. Management in network mode …………….……...…….……...….….….. 15
8. Rules for Installation ……………...…….……………...…….……………...… 15
CONTENTS

Integrated Access Controller – Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved. 3
1. Introduction
Controller KDH-KZ2000-IP-U
Controller KDH-KZ2000-IP-M
The KDH-KZ2000-IP-U_M controller has been designed for access control
system and to be mounted on a wall without any additional enclosure. 32 bit
processor ensures fast and reliable data processing. This is one door controller.
With additional reader (also with keypad) it can use for two way control. Recom-
mended supply power type AWZ-200 plus 7Ah battery.
It’s possibility to set one from four identification mode:
- Card only (default mode)
- PIN only
- Card or PIN
- Card + PIN
KZ-1000-IP can work in standalone (programming from keypad) or in net-
work mode. In network mode it can work on-line or off-line with supervisor KaDe
Premium Plus software II on PC.
KDH-KZ2000-IP-U_M include following components in one cabinet:
• controller module for 1 door
• card reader - 125 kHz ISO UNIQUE - model KDH-KZ2000-IP-U
or
• card reader - 13,56 MHz MIFARE – model KDH-KZ2000-IP-M
• keypad for PIN with bell button
• LED and Buzzer
• anti-disassemble sensor

Integrated Access Controller – Installation manual
4 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
Parameter or function name Parameter value
or function description
Buffer capacity
- Card buffer 20 000 (2 000 in standalone mode)
- Event buffer
- Alarm buffer 50 000
20 000
Electrical parameter
- Supply power 12 VDC
- Current load < 110 mA
- anti-static capability: YES
Environment parameter
- Environment For indoor installation only
- Working Temperature From+2°C to 55°C
- Relative Humidity 0% - 95%
- Size (L x W X H) 122 x 77 x 39 mm
Communication ports
For connection with KaDe Premium Plus - TCP
For additional module connection - RS485 (for future used)
Readers and Cards
- Integrated reader For UNIQUE card, read range 5 - 10 cm (U)
For MIFARE card, red range 2– 5 cm (M)
- External (for two way control) 26 (U)/34(M) bit Wiegand output format
- Card format ISO UNIQUE (125 kHz)
MIFARE (14443A) (13,56 MHz)
- External reader keypad PIN format 4-bits, without buffering
Inputs
- Door contact input NO / NC (NO - default)
- Exit button input NO / NC (NO - default)
- PIR input NO / NC (NO - default)
Relay output
- Strike (lock) control Relay DC 12V 1A (NO / C / NC)
- Alarm control Relay DC 12V 1A (NO / C / NC)
- Bell control NO/NC
Access level parameter
- Access level 200
- Schedule 184
- Holiday 32
Identification mode Card, Card + PIN, PIN , Card or PIN
Alarm relive Automatic, manually by operator or by card
2. KDH-KZ2000-IP-U_M controller technical data

Integrated Access Controller – Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved. 5
Controller module include:
• Communication port TCP for direct connection with KaDe Premium Plus II
• Second reader port for two way control (Wiegand output format)
• Door status sensor input
• Exit button input
• Movement detector input
• Communication port RS485 for connection with additional modules
(for future used)
• Supply Power connectors (+12V, 110 mA)
• Lock control relay output
• Alarm relay output
• Bell control output from keypad key
LED located on front panel - upper left light in:
RED - as supply power indicator
Blue - access granted (light when door unlocked)
Green - programming mode
All components are mounted in esthetics case. KDH-KZ2000-IP-U_M controller is
designed for indoor use only. When entry from outdoor is needed, additional out
door reader should be connected ( np. C-61-W26/34, C-71-W26/34 for version U
or C-100/110M for version M)
Controller back side - connectors view
(pin connectors description on the next page)
J6
J7
J5
J4
J3
8 pin
2 pin
6 pin
4 pin
4 pin

Integrated Access Controller – Installation manual
6 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
TX+ White-
orange TCP network Transmission +
TX- Orange TCP network Transmission -
RX+ White-
green TCP network Receiver +
RX- Green TCP network Receiver -
J3 connector - 4 pin
D0 Green Wiegand D0 - external reader port
D1 White Wiegand D1 - external reader port
BUZ Blue LED /Buzzer of external reader
SW Purple Door contact
AN Gray Exit button
ALM Yellow PIR sensor input
485+ Black RS485 port - signal +
485- Red RS485 port - signal -
-12V Black Controller supply power -12 VDC
-12V Black Supply power for extern. reader -12 VDC
+12V Red Controller supply power +12 VDC
+12V Red Supply power for extern. reader +12 VDC
J4 connector - 4 pin
J5 connector - 6 pin
2NC Black Lock relay - out NC
2C Red Lock relay - out C
2NO White Lock relay - out NO
1NC Yellow Alarm relay - out NC
1C Orange Alarm relay - out C
1NO Green Alarm relay - out NO
J6 connector - 8 pin
BE Black Bell button
BE Red Bell button
J7 connector - 2 pin

Integrated Access Controller – Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved. 7
J5 connector - 6 pin
2NC Black
2C Red
2NO White
1NC Yellow
1C Orange
1NO Green
Electric lock connection — NC type
Electric
lock
VDC
J5 connector - 6 pin
2NC Black
2C Red
2NO White
1NC Yellow
1C Orange
1NO Green
Electric lock connection — NO type
Electric
lock
VDC
D0 Green
D1 White
BUZ Blue
SW Purple
AN Gray
ALM Yellow
485+ Black
485- Red
J6 connector - 8 pin
Reader, door status sensor, exit button and PIR motion detector connection
12
VDC
Reader
Door status sensor
PIR
detektor Exit
button
J5 connector - 6 pin
2NC Black
2C Red
2NO White
1NC Yellow
1C Orange
1NO Green
Alarm sounder connection
Alarm
sounder
VDC

Integrated Access Controller – Installation manual
8 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
Switch TCP
Supply power
12 VDC AWZ-200
Battery
7 Ah Door
bell
Electric
lock
Sound
alarm
KDH-KZ2000-IP-U_M
controller
RS485
For future use
Alarm
sensor
Exit
button
Door
Status sensor
Reader
KaDe Premium Plus II
supervisor software
Buzzer
Battery
+
Tamper
Administrator and
communication
password reset
(read notes p.15)
J3
J6 J4
J7
J5
Block diagram of KDH-KZ2000-IP-U_M controller accessories connection
(details description on the previous page)

Integrated Access Controller – Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved. 9
Installation instruction
1. Unscrew the bottom screw and separate
the rear panel of the controller. Use it as a tem-
plate for the mounting holes. Drill 4 holes for
the mounting screws and one in the middle for
the cables.
2. Attach the back cover of the controller to
the wall. Place the plugs from the wires in the
appropriate sockets and drag them to the other
side of the wall.
3. Mount the controller module on the back
cover. Pay attention to the slot on the top edge
of the controller case and use it as a catch.
4. Push the controller module with the hous-
ing to the back cover and secure it with a screw
from the bottom.
Wall
Back cover
Controller module
Metal cabinet
Gap

Integrated Access Controller – Installation manual
10 AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
5. Programming controller in standalone mode
Controller KDH-KZ2000-IP-U_M can be operated in stand-alone mode or
network under the supervisory software KaDe Premium Plus II installed on your
computer.
Working in stand-alone mode (without communication with the supervisor soft-
ware on the PC) must be programmed using the controller's built-in keypad.
There is no in this mode the possibility to monitor the system "on-line" and gen-
erate reports. Cards added in this mode works without any time limit. This mode
is recommended for the control a few doors with a small number of users.
It is also possible operation of the controller in the "off-line" after being pro-
grammed by supervisory software with controller connecting using TCP port.
Programming procedure using the keyboard controller
Signalling functions:
• audible alarm (buzzer)
• Single long sound - the operation succeeded or enter the menu
• Triple sound - the operation was not successful
• Quad sound - at the selected position is already stored card
• Triple sound - card with this number is already added
• Optical indicator (LED)
• Red LED - Power on
• Blue LED - confirmation of the validity of the operation
• Green LED / steady light - programming mode
5. 1 The procedure for entry into the programming mode:
• Press *
• Enter the master code (default "000000")
• Green LED should light up permanently
If no password is entered correctly within 20 seconds after pressing * it auto-
matically returns to normal. Even after entering the programming mode, no key-
pad operation for 20 seconds to exit the programming mode. After entering the
programming mode, you can make only one type of operation. To perform the
next operation re-enter the programming mode.
Notes: Default admin code 000000 must be change after first enter into pro-
gramming mode for own using 41 command code. Leave default code allows un-
authorized persons enter into programming mode and add own card. Reset ad-
min password is available from KaDe Premium Plus II software - > Controller
setup -> Context menu/Initialize. New password should be download to the con-
troller.
Procedure exited from programming mode:
(After programming)
• Press # - a single sound, red LED light.
Questo manuale è adatto per i seguenti modelli
1
Indice
Lingue:
Altri manuali AAT Controllori