ABB AccessControl Guida utente

System Manual │01.03.2021
ABB-AccessControl
Branding -- Release 2018-01- 01

Table of contents
System Manual 2CKA001473B5074
│
2
Table of cont ents
1
Overview ........................................................................................................................................................ 5
1.1
Information on the manual ................................................................................................................. 5
1.2
Target group / Qualifications of personnel ......................................................................................... 6
1.3
Introduction to ABB-AccessControl ................................................................................................... 6
1.4
ABB-AccessControl and smartIP ....................................................................................................... 8
1.5
Fundamentals of structured cabling ................................................................................................... 9
1.6
Design lines ...................................................................................................................................... 13
1.7
Basic principles ................................................................................................................................ 13
2
Overview of product range .......................................................................................................................... 14
2.1
Application ........................................................................................................................................ 14
2.2
Areas of application .......................................................................................................................... 15
2.3
Device overview ............................................................................................................................... 16
2.3.1
Setup of article numbers ............................................................................................................ 16
2.3.2
Cylindrical lock ........................................................................................................................... 17
2.3.3
System devices .......................................................................................................................... 20
2.3.4
Accessories ................................................................................................................................ 23
2.3.5
Mounting possibilities ................................................................................................................. 24
2.3.6
Prerequisites .............................................................................................................................. 24
2.3.7
Measuring the cylindrical lock ..................................................................................................... 26
2.3.8
Dismantling old cylindrical locks ................................................................................................. 28
3
Commissioning ............................................................................................................................................ 31
3.1
Overview of commissioning ............................................................................................................. 31
3.2
Prerequisites .................................................................................................................................... 32
3.1
Commissioning of the system - "Smart Access Point Pro" ............................................................. 33
3.1.1
Overview .................................................................................................................................... 33
3.1.2
Connecting a PC with the "Smart Access Point “ ....................................................................... 33
3.1.3
Preliminary information: Selection of the system mode .............................................................. 35
3.1.4
Commissioning the "Smart Access Point" .................................................................................. 36
3.1.5
Preliminary information: Adjusting IP addresses to a PC............................................................ 49
3.2
Adding devices ................................................................................................................................. 51
3.2.1
"Electronic cylindrical lock" ......................................................................................................... 51
3.2.2
Adding larger projects / devices in advance ............................................................................... 55
3.2.3
"RF/IP Gateway" ........................................................................................................................ 55
3.2.4
"RF Repeater" ............................................................................................................................ 56
3.3
Delete device in the "Smart Access Point" ...................................................................................... 58
3.3.1
"Electronic cylindrical lock" ......................................................................................................... 58
3.3.2
"RF/IP Gateway" ........................................................................................................................ 58
3.3.3
"RF Repeater" ............................................................................................................................ 58
3.4
Backup / restore the project ............................................................................................................. 59
3.5
RESET (Reset system / devices) .................................................................................................... 60
3.5.1
"Smart Access Point" ................................................................................................................. 60
4
Information about planning and application ................................................................................................ 62
4.1
Principles of function / principles of operation ................................................................................. 62
4.2
Capacity / Transmission range ........................................................................................................ 65

Table of contents
System Manual 2CKA001473B5074
│
3
4.3
Case studies..................................................................................................................................... 69
4.3.1
One-family house ....................................................................................................................... 69
4.3.2
Multifamily house with one floor ................................................................................................. 71
4.3.3
Multifamily house with several floors .......................................................................................... 73
4.3.4
Multifamily house with a medical practice ................................................................................... 75
4.3.5
Residential building with a longer floor ....................................................................................... 79
4.3.6
Residential buildings with several floors ..................................................................................... 83
4.3.7
Perimeter.................................................................................................................................... 87
4.4
Sources of interference .................................................................................................................... 93
5
Management software in the "Smart Access Point Pro" ............................................................................. 94
5.1
Overview .......................................................................................................................................... 94
5.2
Building structure ............................................................................................................................. 95
5.2.1
Creating buildings....................................................................................................................... 96
5.2.2
Creating floors ............................................................................................................................ 99
5.2.3
Creating rooms ..........................................................................................................................101
5.3
Device configuration....................................................................................................................... 103
5.3.1
Add "Smart Access Point Pro" ...................................................................................................104
5.3.2
Add "Electronic cylindrical lock" .................................................................................................105
5.3.3
"Electronic cylindrical lock" Settings ‒ Emergency function .......................................................107
5.3.4
Add "RF/IP Gateway" ................................................................................................................108
5.3.5
Add "RF Repeater" ....................................................................................................................111
5.4
Access control ................................................................................................................................ 113
5.4.1
Placing the "Smart Access Point Pro" .......................................................................................114
5.4.2
Placing the "RF/IP Gateway" .....................................................................................................117
5.4.3
Placing the "Electronic cylindrical lock" .....................................................................................120
5.4.4
Coupling the "Electronic cylindrical lock" with the "Smart Access Point Pro" .............................122
5.4.5
Placing the "RF Repeater".........................................................................................................126
5.4.6
Coupling the "RF Repeater" ......................................................................................................129
5.5
User management .......................................................................................................................... 131
5.5.1
Create user ...............................................................................................................................132
5.5.2
Creating user groups .................................................................................................................135
5.5.3
Add authentication.....................................................................................................................138
5.5.4
Assigning locking rights .............................................................................................................143
5.6
Deleting data from the "User management menu ......................................................................... 145
5.6.1
Deleting locking right .................................................................................................................146
5.6.2
Deleting authentication ..............................................................................................................148
5.6.3
Delete users ..............................................................................................................................150
5.7
Deleting data from the "Access control" menu .............................................................................. 152
5.7.1
Uncoupling "Electronic cylindrical lock" from "Smart Access Point Pro" ....................................153
5.7.2
Removing the "Electronic cylindrical lock" from the room ..........................................................156
5.7.3
Removing the "Smart Access Point Pro" from the room ............................................................157
5.7.4
Uncoupling the "RF Repeater" Fehler! Textmarke nicht definiert. ..............................................158
5.7.5
Removing the "RF Repeater" from the room .............................................................................160
5.8
Deleting data from the "Device configuration" menu ..................................................................... 161
5.8.1
Deleting the "Electronic cylindrical lock" from the system ..........................................................162
5.8.2
Deleting the "RF Repeater" from the system .............................................................................163
5.8.1
Deleting the "RF/IP Gateway" from the system .........................................................................164
5.9
Deleting data from the "Building structure" menu .......................................................................... 165

Table of contents
System Manual 2CKA001473B5074
│
4
5.9.1
Deleting rooms ..........................................................................................................................166
5.9.2
Delete floors ..............................................................................................................................167
5.9.3
Delete buildings .........................................................................................................................168
6
Notes .......................................................................................................................................................... 169
7
Index .......................................................................................................................................................... 170

Overview
System Manual 2CKA001473B5074
│
5
1 Overview
1.1 Information on the manual
This manual describes the ABB-AccessControl system. It supports you in the selection and
planning of the correct structure.
It contains an overview of currently available components and provides ideas for practical
combination and integration.
For detailed technical information about the individual components please also note the
respective product documentation.
In Chapter 4.3 “Case studies“ on page 69 the topics of this document are explained by means
of examples. The information in the chapters is structured logically. If you wish to familiarise or
re-familiarise yourself again with the topic, read through all the relevant subchapters on this
topic.

Overview
System Manual 2CKA001473B5074
│
6
1.2 Target group / Qualifications of personnel
Installation, commissioning and maintenance of the device must only be carried out by trained
and properly qualified electrical installers.
The electrical installer must have read and understood the manual and follow the instructions
provided.
The electrical installer must adhere to the valid national regulations in his/her country governing
the installation, functional test, repair and maintenance of electrical products.
The specialist staff should have general knowledge about networks.
1.3 Introduction to ABB-AccessControl
The "Electronic cylindrical lock" are designed and provided for application within the "ABB-
AccessControl" IP system.
Communication and current
The "Electronic cylindrical lock" communicate via radio control. A separate power supply is not
required. The "Electronic cylindrical lock" obtain the necessary power via the supplied batteries.
Scalability
Smaller objects can be installed as easily as large objects. Existing installations can be
extended at all times.
Operation
Central management of all access points via the ABB-Welcome® App app.
Loss of keys
No change of hardware when keys are lost.
New or retrofitting
The "Electronic cylindrical lock" can be installed on almost all doors. Either new or for
retrofitting.

Overview
System Manual 2CKA001473B5074
│
7
Power failure
The "Electronic cylindrical lock" obtain the necessary power via the supplied batteries.
– The "Electronic cylindrical lock" are used independently:
– The "Electronic cylindrical lock" continue to function.
– The "Electronic cylindrical lock" are integrated in a system:
– The "Electronic cylindrical lock" continue to function, the system does not.

Overview
System Manual 2CKA001473B5074
│
8
1.4 ABB-AccessControl and smartIP
Fig. 1: ABB-AccessControl and smartIP
The ABB-AccessControl access control is an integral part of the entire smartIP system.
The ABB-AccessControl access control can be used exclusively for itself. Or it can, as desired,
be supplemented by additional systems or also be integrated into additional systems. This can
take place at any time in the future.
For planning purposes, a separate system manual is available for each system.
smartIP
ABB-Welcome IP
ABB-VideoControl
ABB-AccessControl
Door communication
Video control
Access control

Overview
System Manual 2CKA001473B5074
│
9
1.5 Fundamentals of structured cabling
Structured cabling is a uniform setup plan for a network infrastructure. The network
infrastructure is independent of the application and future-oriented. Additional designations for
the structured cabling are Universelle Gebäudeverkabelung (UGV) (universal structured
cabling) or Universelle Kommunikationsverkabelung (UKV) (universal communication cabling).
Structured cabling is to prevent expensive faulty installations and extensions and also make the
installation of new network components easier.
Unstructured cabling is normally bound to requirements or a specific application. If the
changeover to a new technology or technology generation becomes necessary, this could easily
lead to a cost explosion.
Structured cabling is based on a generally valid cabling structure. This cabling structure, among
others, takes the requirements for several years into the future into consideration. It contains
reserves and can be used independent of the applications. E.g., one lets the local network and
the telephony operate via the same cabling.
Structured cabling includes the following points:
■ Standardized components (wires, connectors, etc.)
■ Hierarchical network topology (star, tree, etc.)
■ Recommendations for laying and installation
■ Standardized measuring, testing and documentation processes
Objectives of structured cabling
■ Support of all current and future communication systems
■ Reserve of capacity regarding limiting frequency
■ Neutral behaviour of the network regarding the transmission protocol and terminal devices
■ Flexible expandability
■ Fail-safe due to star-shaped cabling
■ Implementation of data protection and security
■ Adherence to existing standards
Standards for structured cabling
Area of validity Standard Description
Europe EN 50173-1 (2003) Cabling standard information system - application-
neutral cabling systems
North America TIA/EIA 568 B.1 (2001)
/ B.2 1 (2001) Telecommunication cabling standard for building
cabling
World ISO/IEC 11801 (2002) Cabling standard for application-neutral building
cabling
Table 1: Standards for structured cabling

Overview
System Manual 2CKA001473B5074
│
10
ISO/IEC 11801 (2002) and EN 50173-1 (2003)
P
1500 m
1
1
500 m
2
90 m
12
90 m10 m
100 m
A
B C
D
12 12
E
3
45
6
Fig. 2: Structured cabling
Indice