ABL POLEMH6 Manuale utente

EN
Article No.: 0301697_EN_a
Installation manual
POLEMH6

| Contact
ii
Contact
ABL GmbH
Albert-Büttner-Straße 11
91207 Lauf an der Pegnitz
Germany
+49 (0) 9123 188-0
+49 (0) 9123 188-188
www.ablmobility.de
Customer Service
+49 (0) 9123 188-0
www.ablmobility.de/de/service/support/
Revision:0301697_EN_a,version:10/12/2021
T
h
i
n
k
b
e
f
o
r
e
y
o
u
p
r
i
n
t
NOTE
Please note that the wallboxes shown on the cover sheet are not included with the POLEMH6, but can be ordered
separately for a fee.

Contents | iii
Contents
Contact ii
Additional technical information iv
Intended use iv
Information in this document iv
Important information 5
General 5
Safety instructions 5
User information 6
Dimensional drawings and dimensions 8
POLEMH6 8
EMH9996 9
Introduction to the POLEMH6 11
Identification of the POLEMH6 11
Items supplied 11
Accessories 12
Installation 13
Requirements for the installation site 13
Specifications for the mechanical
installation of the POLEMH6 13
Laying the EMH9996 foundation 14
Installing the POLEMH6 on the EMH9996
foundation 16
Specifications for the mechanical and
electrical installation of the wallboxes 19
Installing the eMH3 Wallbox on the POLEMH6 20
Electrical connection of the POLEMH6 23
Note on the installation of a second
eMH3 Wallbox 25
Safety instructions for start-up and operation 26
Troubleshooting and maintenance 27
Maintenance 27
Appendix 28
Technical specifications 28
Protection classes & degrees of protection 28
Trademarks 29
Intellectual property & copyright 29
Disposal notice 29

| Additional technical information
iv
Additional technical information
Additional technical information is required to install an eMH3 Wallbox on the POLEMH6 mounting pole, as well as
regarding further accessories. It is contained in separate documents.
In addition, the technical data for your mounting pole and the accessories are collated in product-specific data
sheets. You can download these documents from the ABL website using the following link:
https://www.ablmobility.de/en/service/downloads.php
NOTE
Displaying the additional information on a computer, tablet or smartphone
Additional technical information is made available in the Portable Document Format (PDF).
To display PDF files, you need the free Adobe Acrobat Reader or comparable software.
You can find further information about our product range, as well as about separately available accessory compo-
nents on our website at www.ablmobility.de/en. Please visit:
https://www.ablmobility.de/en
Intended use
The POLEMH6 mounting pole is designed for the outdoor installation of one or two eMH3 Wallboxes. In order to en-
sure the necessary stability, the POLEMH6 can be installed on the optionally available EMH9996 concrete foundation
or on a self-constructed concrete foundation. To protect the installed wallbox from the weather, ABL offers the com-
patible WPR36 weather shield. For cable management at the charging point, the CABHOLD cable holder with charg-
ing plug receptacle can be installed on the POLEMH6 mounting pole.
Information in this document
This document describes the installation of the POLEMH6 on the EMH9996 foundation as well as the subsequent me-
chanical installation and electrical connection of an eMH3 Wallbox to the mounting pole: It is recommended that all
working steps described in this document are carried out by qualified specialist electrical contractors only.
User Specialist electrical contractor
Installation manual (this document)
Additional technical information
Data sheets
Installation instructions WPR12/36
Installation instructions CABHOLD

Important information – General | 5
Important information
General
This manual describes all working steps required to install and/or operate the product it concerns.
Certain sections of this manual are specially formatted for quick and easy reference.
Descriptions listing equally valid options are indicated by bullet points.
1 Descriptions listing operating steps are numbered in chronological order.
DANGER!
Indicates life-threatening electrical voltages
Sections marked with this symbol indicate electrical voltages that present a danger of loss of life or grievous
bodily injury.
Actions marked with this symbol must not be carried out under any circumstances.
WARNING!
Indicates important actions and further hazards
Sections marked with this symbol indicate further hazards that may result in damage to the product or to other
connected components.
Actions marked with this symbol must be carried out with special care.
NOTE
Indicates important information for operation or installation
Sections marked with this symbol indicate further important information and features necessary for successful
operation.
Actions marked with this symbol should be carried out as required.
Passages marked with this symbol contain valuable additional information.
Safety instructions
The safety notices serve to ensure the proper and safe installation, as well as subsequent safe operation of the
device.
DANGER!
Violation of the safety information
Disregard of or actions contrary to the safety information and instructions contained in this manual may lead to
electric shock, fire, severe injury and/or death.
Please pay attention to the following points:
Please read this manual carefully.
Heed all warnings and follow all instructions.
Only use accessories intended and sold for the product by ABL.
Do not install this device in close vicinity to running water, water jets or areas subject to flooding.
The product must not be installed in explosive atmosphere areas (EX areas).
Mechanical installation should be carried out by qualified specialist personnel.

| Important information – User information
6
Electrical installation and testing must be carried out with reference to local rules by a qualified specialist
electrical contractor, who, on the basis of their specialist training and experience, as well as their knowledge of
the relevant standards, is able to assess and carry out the working steps described in this manual and recognise
potential hazards.
WARNING!
Notification or approval requirement for charging stations
Please note that electrical grid operators, energy suppliers or national regulations may require notification of or
approval for the installation or operation of a charging station.
A Duty to Notify applies in Germany according to §19 NAV.
In case of installation faults, or malfunctions that can be traced back to faulty installation, always contact the
contractor who carried out the installation first.
The product must not be covered with other objects or materials.
No liquids or receptacles containing liquids must be placed on the product.
Please note that the POLEMH6 mounting pole must never be installed directly on asphalt! To ensure safe and
proper mechanical installation, the optionally available EMH9996 concrete foundation or a functionally equivalent
alternative must always be provided.
Do not under any circumstances make alterations to the product. Any disregard of this instruction represents a
safety risk, fundamentally breaches the guarantee provisions and may void the warranty with immediate effect.
Malfunctions affecting the safety of persons, connected electric devices or the device itself must be resolved by a
qualified specialist electrical contractor.
Should one of the following malfunctions occur, please contact the specialist electrical contractor who has carried
out the installation of your wallbox and accessories:
yThe product housing has been damaged mechanically, or the housing cover has been removed or can no longer
be closed.
ySufficient protection of the small distribution board against splashing water and/or foreign objects is no longer
provided.
yThe product does not function properly or has been otherwise damaged.
WARNING!
Observation of further safety instructions
Please always observe all further safety instructions in the manuals for the optionally available eMH3 Wallbox
and other accessories for the POLEMH6.
User information
Ensure that rated voltage and rated current of the supply cable at the installation location comply with the param-
eters of your local electricity grid and that the rated output of the wallbox(es) installed on the POLEMH6 is not
exceeded during operation.
Local safety regulations regarding the operation of electrical devices for the country in which you operate the
wallbox(es) installed on the POLEMH6 always apply.
Never install or operate the POLEMH6 in confined spaces. In particular, it must be ensured that vehicles can be
parked at a suitable distance from the POLEMH6 for charging and can be connected to the charging cable without
tension.
Make sure that the POLEMH6 is always closed and locked when in use. All authorised users must be aware of the
'unlock' position of the key.
No user-maintainable parts are located inside the device.
Only have the POLEMH6 repaired by a qualified specialist electrical company.

Important information – User information | 7
An eMH3 Wallbox installed on the POLEMH6 may only be operated after it has been installed without any techni-
cal faults and subsequently approved by a qualified specialist electrical company.
NOTE
Changes to functions and design features
Please note that all technical details, specifications and design characteristics of the product may be changed
without prior notice.

| Dimensional drawings and dimensions – POLEMH6
8
Dimensional drawings and dimensions
The dimensions and mounting points of the POLEMH6 as well as the optional EMH9996 foundation are shown in the
following dimensional drawings.
POLEMH6
Mounting pole for installing up to two eMH3 Wallboxes, front and rear view as well as view from below
(all dimensions in mm)
Detailed view of the front and back
A
D
C
B
D
A
These four thread points are used to attach the mounting plate of the eMH3
Wallbox. The required M8×25 rounded-head screws are included with the
POLEMH6.
BThese two thread points are used for directly mounting the WPR36 weather
shield on the POLEMH6 (see “Accessories” on page12).
CThe supply cable is inserted into the eMH3 Wallbox via the large opening, while
the two small openings are for data cables.
DThese two thread points are each used for directly mounting one CABHOLD ca-
ble holder on the POLEMH6 (see “Accessories” on page12).
1624
1520104
410
426
331
410
360
286
286

Dimensional drawings and dimensions – EMH9996 | 9
EMH9996
ABL offers the EMH9996 foundation as an optional accessory for installing the POLEMH6: The foundation block is
made from grade C20/25 concrete and complies with exposure classes XC4 and XF1 for outdoor use. Integrated
threaded anchors ensure stable and secure installation of the POLEMH6. The supply cable and data cables can be fed
into the mounting pole from below via two recessed empty conduits (DN 100).
NOTE
Using a custom foundation
These instructions describe how to install the POLEMH6 on the EMH9996 concrete foundation. In principle, it is
possible to make a custom foundation, but this must be based on the specifications of the EMH9996.
If you wish to install and operate the POLEMH6 on a self-made foundation, a stable base and fault-free oper-
ation outdoors cannot be guaranteed.
Concrete foundation for installing a POLEMH6 mounting pole, section as well as isometric, top and front view
(all dimensions in mm)
420
420
2× DN100
M10
420
420
420
12080
163
286
420
286
30°

| Dimensional drawings and dimensions – EMH9996
10
Detailed view of the top side
A
A
B
C
A
These four threaded anchors are used to mount the base of
the POLEMH6 mounting pole using the washers and M10×35
hexagon socket screws supplied.
BThe two empty conduits are used to feed the supply and data
cables through the foundation into the POLEMH6.
CIf the POLEMH6 is installed outside the rolling sphere,
grounding anchors can be attached here with M12 threads.
Indice