Abloy DA400 Manuale utente

ABLOY®
DA400
Swing door operator
PROGRAM VERSION 1.5
PICOMED

CONTENTS
GENERAL
INSTALLATION
ADJUSTING DOOR MOVEMENTS
CONTROL POINTS
CONNECTIONS
BATTERY OPERATION
FIRE DOOR SYSTEM
PROGRAMMING HANDSET
CONNECTION EXAMPLES
Technical data
Construction & operation
Removal of housing
Function switches
Installation
Electrical connections
Adjusting door movements
Control points
Internal connections
External connections
Battery operation
Battery adapter
Fire door system according UL requirements
ABLOY fire door system
Programming handset
Connection examples
Connections with electric locks
1
2
3
3
4
7
8
11
18
20
22
26
27
28
29
30
31

DEAR CUSTOMER
You have acquired an electro-mechanical automatic swing door operator, the
safety of which has been proven through our research and development and
field tests. The modern Scandinavian design available in three different
colour alternatives will ensure its acceptabily in the various enviromentally
demanding applications.
ABLOY's extensive network of sales and after-sales service points will ensure
long and trouble-free service life for the automatic swing door operator.
The automatic swing door operator has been approved by the Electrical
Inspectorates of FINLAND, DENMARK, NORWAY and SWEDEN.
The installation and service of the automatic swing door operator must be
carried out in accordance with the installation instructions. Only persons who
have undertaken ABLOY product training may install and comission the
automatic swing door operator.

GENERAL INFORMATION
Approvals
Warnings
Low Voltage Directive (Finland, Sweden, Norway, Denmark)
EMC Directive (European Community)
UL (United States of America)
CSA and ULC (Canada)
Fire door use (Finland, USA, Canada)
Closing force must not exeed 178 N (40 lb) for a pedestrian application.
Closing time for last 10° (degrees) must be at least 1,5 seconds (UL requirement).
The fire adapter (see page 30) must be used in fire doors applications
in USA and Canada.
In fire door applications the operator must be equipped with battery back-up.

1
TECHNICAL DATA
The automatic swing door operator is intended for both new and existing swing
door applications, internal and opening out external doors. The automatic
swing door operator can be used in residential units, institutions, shops, public
buildings, warehouses and offices.
Operating conditions
For use in dry premises, temperature
range -10...+50 C
Stored in dry premises, temperature
range -30...+85 C
The automatic swing door operator
must not be installed in applications
where it is subjected to water or snow
o
o
Technical data
Supply voltage 115/230 V AC
50/60 Hz, Rated output 50 W
Stabilized voltage from operator to
impulse devices and electric locks
12 and 24 V DC
Enclosure class IP 20
Micro-processor control
Programmable adjustment of all door
movement functions
Operator dimensions and door
weights shown in installation drawings

CONSTRUCTION & OPERATION
2
Control unit
Direct current - motor
Pulse counter
Pulse disk
Safety clutch
The operation of the automatic swing door operator
is controlled by a microprocessor.
ABLOY
The body and the housing of the operator are manufactured from aluminium.
The body is secured to the wall or transom by four fixed bolts following the
installation of the mounting plate with the power switch side of the unit
mounted towards the hinge side of the door.
The operation of the automatic swing door operator is influenced by its
control unit, where connections for electric locking and impulse devices are
made. All control impulses must be volts free (N.O) Normally open. All the
functions of the control unit are determined by a microprocessor.
The functions of the automatic door operator, e.g. opening and closing speed,
lock-up force, and the load required by the door are programmed using the
push-buttons mounted on the control unit. The digital display indicates the
values set. Also available is a programming handset.
The control unit can also be programmed for power-assisted manual
opening; when the door is opened slightly, the operator will automatically
open it.
In the event of a power failure the swing door operator can be equipped with
a back-up battery. A flashing red LED warns when battery needs
replacement.
A safety clutch to the drive shaft protects the door operator against
mechanical damage. The clutch will slip if the door is opened by force.

REMOVAL OF HOUSING
3
SWITCHES
Program selector:
2
- position switch
= AUTOMATIC: The impulse device connected to the door
operator will open the door and close it after a preset door open
time. The hold open time can be adjusted between 0...60 s
(control points 7 or 17).
Power-assisted manual opening is also active during this period.
= The door opens and remains open. On switching to either
AUTO or MANUAL the door will close after a preset delay.
AUTO
OPEN
IO
AUTO OPEN
Warning!
Disconnect mains supply
when removing or
mounting the housing.
Remove the housing by
inserting a wide-blade
screw driver at each
end.
The automatic swing door operator is mounted
with the end to the is
located towards the hinge side of the door. When the
door operator is switched on, the red LED on the
mains switch lights up. The mains supply
should always be on to ensure that the back-up
battery is being charged.
mains switch
Switch:I=ON,0=OFF.
Disconnect mains
supply when
making electrical
connections.

INSTALLATION
4
Extension piece
Note!
6
Inspect the swing door operator against transport damage.
Test the free swinging of the door, which should open and close smoothly.
The automatic swing door operator is to be installed on the transom, with the
mains switch located towards the hinge.
For , the door operator is mounted on the stop side of the door
installing the standard arm 7281 or 7282.
For , the door operator is mounted on the hinge side of the door
installing the sliding arm 7611.
Use extension pieces for non standard applications. Maximum extension
shaft length 60 mm. Extension shafts: 10 mm, 20 mm, 60 mm.
push function
pull function
Mount a door stop to the door open position so that wind will not drive the
door against the wall, resulting in damage.
The door stop can be either floor or wall mounted.
DOOR SIZE/DOOR WEIGHTS
Standard arm
7281, 7282 for
push function
Sliding arm
7611 for pull
function
Door width max. 1 m ... max. 125 kg
Door width max. 1.15 m ... max. 100 kg
Door width max. 1.3 m ... max. 90 kg
Door width max. 1 m ... max. 80 kg
Door width max. 1.15 m ... max. 70 kg
Door width max. 1.3 m ... max. 60 kg
Sliding arm 7611
Standard arm 7281, 7282
When specifying, please take account of door surroundings
and exposure to weather conditions

INSTALLATION
Drill the installation holes as shown in the drilling diagrams.
Attach the door operator to the mounting plate with four screws M8 x 25
provided.
Use the mounting plate delivered with the door operator ensuring the installation
base is level and securely fixed. Minimum wall thickness
should be 5 mm if the door frame is of metal construction.
The door operator's frame and mounting plates are provided with wiring holes
enabiling concealed wiring.
a) Push function
drilling diagrams
- use mounting plate DA100
- frame depth max. 150 mm with standard
arm 7281 or DA140, and 150-250 mm with standard
arm 7282 or DA141
- sliding arm 7611 can be used in lightweight
doors (max. opening angle 90 )
- arms DA140 and DA141 are also provided
with inch machine screws
o
IO
90o
70
Opening angle
max. 100
o
ARM W
7281 0 - 150
7282 150 - 250
284 70
W
90°
5
EX
EX
DA100
YZY Z
Y
Z
95 60
95 60
85 5085 50
75 4075 40
65 3065 30
55 2055 20
45 1045 10
35 035 0
100
108
100
184
25
70
331.5
30
45
568
284
89
62
32.5
15

6
INSTALLATION
Drill the installation holes as shown in the drilling diagrams.
Attach the door operator to the mounting plate with four screws M8 x 25
provided.
Use the mounting plate delivered with the door operator ensuring the installation
base is level and securely fixed. Minimum wall thickness
should be 5 mm if the door frame is of metal construction.
The door operator's frame and mounting plates are provided with wiring holes
enabiling concealed wiring.
b) Pull function
drilling diagrams
- use mounting plate DA100
- use sliding arm 7611 or DA142
- minimum door width for sliding arm application
is 750 mm
- arm DA142 is also provided with inch machine
screw
IO
IOII
565
Opening angle
max. 100
o
EX
EX
MOUNTING PLATE DA100MOUNTING PLATE DA100
YZ
95 60
85 50
75 40
65 30
55 20
45 10
35 0
100 100 184
26.75
26.5
26.75
Y
535
L
108
568
20
29,5 in DA142
Z
M
PULL FUNCTIONPULL FUNCTION
FRAME DEPT DISTANCE FROM HINGE LINE MIN DOOR WIDTHFRAME DEPT DISTANCE FROM HINGE LINE MIN DOOR WIDTH
HL MH L M
0 - 150 180 7500 - 150 180 750
150 - 200 265 835150 - 200 265 835
200 - 250 300 870200 - 250 300 870
H
Altri manuali per DA400
1
Indice
Altri manuali Abloy Sistema di apertura della porta