ActiGraph CentrePoint Insight Watch Manuale utente

CentrePointInsightWatch |E.200.6002 | Released:01/09/2023 | Rev: 7
CENTREPOINT Insight Watch
User Guide

2
THEACTIGRAPH.COM
CENTREPOINTINSIGHTWATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
CENTREPOINT Insight Watch
CentrePointInsight Watch |E.200.6002 |Released:01/09/2023 |Rev:7
User Guide
Overview ................................................................................................................................................................................................... 2
Study Package ..................................................................................................................................................................................... 3
Getting Started ................................................................................................................................................................................... 4
Assignment ............................................................................................................................................................................................ 6
Information for Participants ................................................................................................................................................. 12
Uploading .............................................................................................................................................................................................. 14
Viewing Participant Data ........................................................................................................................................................ 15
Unassignment ................................................................................................................................................................................... 17
Lost or Broken CPW01(s) ......................................................................................................................................................... 20
Frequently Asked Questions ............................................................................................................................................... 22
Regulatory Information ........................................................................................................................................................... 24
Table of Contents
Overview
CENTREPOINT Insight Watch
The CentrePoint Insight Watch (CPW01) from ActiGraph captures and records continuous, high
resolution acceleration data, which are converted into variety of objective physical activity and sleep
measures within the cloud-based CentrePoint software system. This manual provides instructions
on how to setup, deploy, and upload data from the CPW01 to the CentrePoint software system. The
intended user(s) of thisCPW01isthe participantor end-user.
Dimensions
Weight
Samplerate
Batterylife
Datastorage
5.01 x3.46x1.05cm
14grams
32Hertz(default)-256 Hertz
30days*
30 days/512MB
Dynamicrange
Communication
Waterresistance
Wear location
Warranty
+/- 8G
USB, Bluetooth®LE5
1meter, 30minutes
Wrist
1year
*At32Hz(default)samplerate.

3
THEACTIGRAPH.COM
CENTREPOINTINSIGHT WATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
USB Cable
PC + ActiSync Software CentrePoint Account
Wall Plug
Charging Dock
Study Package
CP Insight Watch (CPIW01)
CentrePoint Data Hub + Power Cable (optional)

4
THEACTIGRAPH.COM
CENTREPOINTINSIGHT WATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
Allow rewall access to the following URLs
Contact your local IT department prior to assigning CPW01(s) to ensure the following URLs are whitelisted for open and
secure web communication and have access to the ActiGraph services. Please contact support@theactigraph.com for any
additionalquestionsorfurtherassistance.
Main Web Portal
https://studyadmin.actigraphcorp.com
Site personnel directly accesses this URL to create and
monitorparticipants duringthestudy
CENTREPOINT System Requirements
The CentrePoint system is only compatible with TLS 1.2 or higher security protocols. Contact your local IT department to
ensureyoursystemsmeet the latestsecurity protocolsand haveaccess tothe ActiGraph services.
Internet Browsers
• MicrosoftInternetExplorer11
ornewer
• MicrosoftEdge
• Mozilla Firefox
• GoogleChrome
API Integrations
• Java8(1.8) orhigher
• .NET4.6.2 or newer
• Python2.7.9orhigher
• Ruby2.0or higher
• OpenSSL1.0.1orhigher
• Mozilla NSS 3.15.1 or higher
Operating Systems
• Windows10ornewer*
* Sites using operating systems older than Windows 10 (e.g. Windows 7), should contact ActiGraph support for further instructions.
Getting Started
ActiSync Service
https://studyadmin-actisync-service.actigraphcorp.com
Connection point for the ActiSync client software order to
determine the current assignment status of a device and
instruct ActiSynchowtoproceed
Blob Azure Storage
https://acticlouduploadsprod.blob.core.windows.net
Allows ActiSync to extract the data from the CPW01 and
storeitonourcloudstorage server
Please note: Clicking on the links above does not conrm open access. URLs must be added to the IT whitelist. If
youarehavingtroubleassigninga CPW01and havenotcontactedyourITdepartmentyet,pleasedo so.

5
THEACTIGRAPH.COM
CENTREPOINTINSIGHT WATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
Charge the CPW01
TheCPW01 shouldbefully chargedbefore assignmentanddeployment.Ittakesup
to2-3 hourstofully chargeaCPW01.Charging temperaturerangeis0°Cto45°C.
Connectthechargingdock toa walloutlet using thesupplied wallplug.
Connectthe CPW01to thechargingdock bypulling theplastic tabonthe
docktotheleftandinsertingtheCPW01withthescreenfacingupandthe
buttonontheoppositeside ofthechargercable.
The CPW01 is fully charged once a solid battery icon appears on the
screen.
Install ActiSync software
DownloadtheActiSyncsoftwarefromhttps://actigraphcorp.com/actisync
Double click the le to open and follow prompts to complete installation.
ActiSync System Requirements
OS Windows 10or later(ActiSyncisnotcompatible withMacOS)
CPU Dualcoreprocessor | HDD 20MB,USB2.0
Getting Started | Continued
1.
2.
1.
2.
3.
Please note: An Internet connection is not required to
chargetheCPW01(s).

6
THEACTIGRAPH.COM
CENTREPOINTINSIGHT WATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
Verify thatActiSync is runningon thePCbycheckingforsmalliconinthe taskbar.
Connect the charging dock to the computer using the provided USB cable and insert the CPW01 into the charging
dock.
Onceconnected, the ActiSyncicon willturnyellow andadialogboxwillopen.
Select“Assign the subject now.”
TheCentrePoint webportalwill openinyourweb browser.
Enter yourCentrePointlogininformation.
CPW01(s) will be assigned to participants at Visit 1. Participants are instructed to bring the CPW01,
chargingdock,andallaccessoriesbacktotheFinalVisit,duringwhichtheCPW01willbeunassignedand
returned toinventory.
Assignment
Assigning a CPW01 to a new participant
Assigning a CPW01 to a new participant will take approximately 3-5 minutes. Make sure the CPW01 is fully charged prior to
assignment.
1.
2.
3.
4.
5.
6.

7
THEACTIGRAPH.COM
CENTREPOINTINSIGHT WATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
CompleteDevice Assignment by enteringthefollowing information:
• Site:Selecttheappropriatesitefromthedropdownmenu.Sitecoordinatorswillonlyhaveoneoptionavailable
(theirsite).Ifyouhaveaccesstomorethanonestudy,selectthecorrectstudybeforeyoucontinuewithDevice
Assignment.
• Subject Identier: This will be six characters long (XXX-XXX), where the rst three characters will be prelled
withyoursiteIDandthelastthreenumericdigitsaretheparticipantnumber.
• Dateof Birth:(DD-MM-YYYY)
• Weight:(kgor lbs)
• Wear position:Left Non-DominantWrist or Right Non-Dominant Wrist.
Select“Assign Device to a New Subject.” Waitforprogress bartoindicatethat assignmentiscomplete.
Assignment | Continued
7.
8.

8
THEACTIGRAPH.COM
CENTREPOINTINSIGHT WATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
Removethe CPW01from the chargingdockbypullingtheplastictabtothe right andawayfromtheCPW01.Wait for
theCPW01togo fromhalt modeintoactivemode,asindicatedbytherunningpersoniconintheupperleftcornerof
thescreen.This takesapproximately90 seconds.
Active Mode
A running person icon will
be displayed if the CPW01 is
collecting data.
Halt Mode
Stopiconwillbedisplayedif
the CPW01 is not collecting
data.
Assignment | Continued
9.
10. Pair the CP Data Hub with the CPW01
(Ifyou’renotusingaCentrePointData Hub,skipaheadtoInformation for Participants)
• ConnecttheadapterendofthepowercableintothebackoftheCPDataHubandplugtheotherendintoawalloutlet.
• The blue LED status light on the back of the CP Data Hub will ash during startup. It may take up to 20 seconds for
the light to begin to ash. Once the CP Data Hub connects to the cellular network, the blue LED light will stay on solid.
• Connectthechargingdock totheUSBportonthe CPDataHub using theUSB cable.
Power Status LightUSB Port

9
THEACTIGRAPH.COM
CENTREPOINTINSIGHT WATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
Assignment | Continued
• InserttheCPW01intothechargingdock.Onceconnected,aprogresswheelwillappearonthescreenindicating
thatan upload hasbegun.Whentheuploadis complete,acheck-markwill appearon thescreen.
Please note: If you see a warning sign on the screen of the CPW01, remove it from the charging
dock and insert again. Make sure you see a check-mark on the screen before proceeding to the
next step.
Upload in
Progress
Upload
Complete
Verify connection and test upload status in CentrePoint
• Login to the CentrePoint web portal. Select the “Subjects” tab from the left hand menu, and select the desired
subjectfrom thelist.
11.

10
THEACTIGRAPH.COM
CENTREPOINTINSIGHT WATCH | E.200.6002 | RELEASED:01/09/2023 | REV: 7
Assignment | Continued
RemovetheCPW01fromthechargingdockbypullingtheplastictabtotheleftandawayfromtheCPW01.
12.
• You will be directed to the “Subject Details” page. Select the “Subject Timeline” tab, and verify that an upload
hasoccurred viaDataHub USB.The CPW01andtheCPData Hubarenowpaired.
Assignment Completed
Give the CPW01, charging dock, and all accessories to the participant and provide the following instructions:
Wear the CPW01 securely on your non-dominant wrist for 24 hours a day for the duration of the study. There is no need
to remove the CPW01 for bathing or other water activities. There is no need to remove the CPW01 at night or during sleep
periods.
Use the charging dock to fully charge the CPW01 once every 3 weeks. Be sure to bring the CPW01, charging dock, and all