ACBU011/ACLU011 User Manual
Page 10 of 21
Figure 4.2 — Redundancy Status Window
POWER SUPPLY: Redundancy power supply provides by two ways: by DC
power supply (U DC1 and U DC2) and by RF connector from modem (Umodem).
Function displays current income voltage and power port connection. Voltage is
in OK if it’s value within acceptable limits and ERROR if voltage out of limits.
To set voltage limits go to menu tab Parameters.
WS STATUS: displays current position of waveguide switch (fig 3.3).
Figure 3.3 — WS RF paths positions
Current position status will be OK, other will be ERROR;
REF MODE INTERNAL: displays status of reference frequency mode; OK if
Internal mode, ERROR if External mode.
POWER STATUS: displays power or amperage appliance of BUC. Power or
Amperage is in OK if it’s value within acceptable limits and ERROR if out of
limits. Device turn’s off BUC if power or amperage parameters are out of limits.
To set limits go to menu tab Parameters.