Table of contents
Introduction……………………………………………….……………..………...5
Receiving and
inspection…………………………………………………..…………………...…..6
Equipment Damage or Loss
Return of Equipment
Preparing for
installation…………………………………………………….…………..…….…..7
Safety Precautions
General
description………………………………………………..…………….……….…..8
Considerations
Securing the Block Up Converter
Installing the Block Up
Converter…………………………………………………………………………..………………...…...9
LED Indicators, Connector Pin Assignment, 10MHz Reference
Powering Options, Setting L.O., Setting Tx/Rx Frequencies
Recommended Test
Equipment…………………………………………………………………….………………………...13
Technical
Specifications………………………………………………………….….………..14
Assembly and
Installation………………………………………………………………….………15
Connections and Mounting Hardware
Functional
Overview………………………………………………………….………………16
General
IF/RF Conversion and Amplification

ABE20KX User Manual
Page 3 of 36
Monitor and Control (optional)
Operation
Procedure……………………………………….....…………….………………...17
Maintenance……………………………………….…………………..….........….18
Preventive Care
Procedure
Block Up Converter Cooling System Preventive Maintenance
Performance Check
Troubleshooting
Out-of Warranty Repair
Appendix 1 Mechanical
Drawing……………..………………………………….………….……………....20
Appendix 2 Spare Parts Order
Form…………………………………………….………………………………….21
Appendix 3 M&C
Commands…...………………………………………………….…………………..22
Appendix 4
BUC 19 pin connector ……………………………….…….……………...………..27

ABE20KX User Manual
Page 4 of 36
Scope
This document covers the installation, operation, and maintenance of the ABE20KX BUC. It contains
information intended for engineers, technicians and operators working with the block up converter.
To make inquiries, or to report errors of fact or omission in this document, please contact Actox
Corporation at toll free 866-888-6087.

ABE20KX User Manual
Page 5 of 36
INTRODUCTION
The ABE20KX is a reliable, high quality, cost efficient stand-alone block up converter. The application
for this block up converter is Ku-Band VSAT communication in an outdoor environment. This line of
superior products, engineered using state of the art technology, is characterized by unparalleled durability
and dependability.
This is the smallest and lightest 20W L-To Ku-Band Block Up Converter and is designed to be mounted
on the feed horn. The unit is ideal for portable and mobile applications. Double – L.O. feature makes unit
universal for Ku-Band requirements. This unit can be powered either with 24 and 48 VDC and consumes
less than 135W.
KEY FEATURES
13.75-14.50 GHz
950 to 1,700 MHz
Smallest package size and weight
Double L.O. (switchable 12.80 and 13.05GHz)
Auto-ranging 15-60 VDC power option
Low power consumption (135W max)
Digital temperature compensation
L.O. lock and amplifier LED
M&C – combined RS-232/485/FSK(optional)
RoHS compliant
ABE20KX – 20W Ku-Band BUC monitors and controls numerous parameters and has features that make
installation and use of the BUC simpler and enhance system performance.

ABE20KX User Manual
Page 6 of 36
Receiving and Inspection
The block up converter is designed to function outdoors and will arrive in a standard shipping container.
Immediately upon receipt of the block up converter, check the packing slip against the actual equipment
you have received. Inspect the shipping containers exteriors for visible damage incurred during shipping.
CAUTION!
Handle the block up converter with extreme care. Excessive shock may damage block
up converter’s delicate internal components.
Using the supplied packing list, verify that all items have been received and undamaged during shipment.
Verify that all items are complete. If there are any omissions or evidence of improper packaging, please
notify Actox Corporation immediately.
Equipment Damage or Loss
Actox Corporation is not responsible for damage or loss of equipment during transit. For further
information, contact the responsible transport carrier.
When declaring equipment as damaged during transit, preserve the original shipping cartons to facilitate
inspection reporting.
Return of Equipment
When returning equipment to Actox Corporation for repair or replacement:
Identify, in writing, the condition of the equipment,
Refer to the Invoice, Purchase Order and the date the equipment was received.
Notify Actox Corporation RMA department of the equipment condition and obtain a Return Material
Authorization (RMA) number and shipping instructions.
NOTE
Do not return any equipment without an RMA number.
This is important for prompt, efficient handling of the
returned equipment and of the associated complaint.

ABE20KX User Manual
Page 7 of 36
Preparing for Installation
Before attempting to install or use the block up converter, we recommend that you first familiarize
yourself with the product by reading through this manual. Understanding the operation of the system will
reduce the possibility of incorrect installation, thereby causing damage or injury to yourself or others. The
block up converter must be installed in accordance with the conditions and recommendations contained
in the following sections.
Safety Precautions
Carelessness or mishandling of the block up converter may damage the unit causing serious injury to
yourself or others. Please adhere to the following:
WARNING!!
If your unit is equipped with an AC power cord and plug, do not tamper with, or attempt to
reconfigure, the cord or plug supplied with the unit, as this can:
Result in personal injury;
Void the warranty;
Cause damage to the units or related equipment.

ABE20KX User Manual
Page 8 of 36
INSTALLATION AND OVERVIEW
General Description
This section describes the installation and theory of operation of the block up converter.
ABE20KX is powered by +15~+60 VDC via IF cable.
It will amplify an input signal from an L-Band RF source up to a power level of 20 Watts (min) CW in
Ku-Band.
The block up converter can be used as a stand-alone unit or in a redundant configuration.
Specifications
Table 1 summarizes the specifications of the ABE20KX BUC. For mechanical specifications, refer to the
outline drawing, Appendix 1.
General Considerations
The block up converter shall meet all specifications over full bandwidth and under all environmental
conditions when terminated with a load of VSWR at 2:1 unless otherwise specified. All RF specifications
shall be met within five minutes after applying power, except gain flatness, which shall be met after a
warm-up period of ten minutes. During the warm-up period, the block up converter shall not exhibit any
alarm or require an RF mute input signal to reset any alarm/fault latches.
Securing the block up converter
Align the block up converter output waveguide flange with the mating flange of the antenna feeder
waveguide. Using the O-ring and hardware provided, connect the antenna feeder waveguide. Torque the
flange screws to 16 inch-pounds (1.8 N-m). Attach the proper cables for waveguide for IF input, AC
power and M&C if equipped to the corresponding connectors of the block up converter.
The cylindrical connectors are labeled clearly and have different pin layouts. It is
impossible to incorrectly install the mating connectors.

ABE20KX User Manual
Page 9 of 36
Installing the Block-Up Converter
Tools and Test Equipment
Have on hand a standard electrician's tool kit and any tools listed in the antenna
manufacturer's installation instructions.
Site Considerations
The BUC is designed to mount on the antenna. Locate and install the antenna according
to instructions supplied by the antenna manufacturer. Choose an area that is free of
extraneous interference from motors and electrical equipment and has a clear line of sight
from the antenna to the satellite. Lightning arrestors should be used at the site to protect
personnel and equipment.
Preparation
Mounting Considerations:
Optional Mounting Brackets are available that will facilitate mounting for most antennas.
The ODU must be mounted such that:
- Sufficient support is afforded to the BUC, the LNB and the Power supply to minimize
the effects of antenna sway in strong winds.
- Air movement across the heat fins is possible.
- The length of the Power supply cables is taken into consideration in determining the
mounting location of the power supply.
Throughout installation and during any polarization, azimuth or elevation adjustment,
ensure that cables and waveguide are not crimped or pinched.

ABE20KX User Manual
Page 10 of 36
M&C Connection for 19-Pin
19 pin conn 9 pin conn
GND G ------------------5
TX 232 J -------------------2
RX 232 E -------------------3
The following should be set on the COM Port:
Baud Rate: 9600bps
Data bits: 8
Stop bits: 1
Parity: None
HW Control: None
LED Indication
SSPA LED Green All OK
SSPA LED Red Summary Alarm
L.O. LED Blinking Yellow L.O. is set to 12.80GHz
L.O. is set to 13.05GHz
NO POWER
External 10MHz Reference
10MHz is Absent
Internal 10MHz Reference
L.O. LED Yellow
NO LED indicators
10MHz LED Green
10MHz LED Red
10MHz LED Green Blinking
Connectors' Pin Assignment
Connector Type Pin # Signal Parameter
J1 "IF IN" F-type female N/A IF Input -0 dBm, max
10 MHz
Ref. IN ±5 dBm
J2 "RF OUT" WR-75 N/A RF Output 43.0 dBm min
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Actox Convertitore multimediale

Actox
Actox ABC40UKA Manuale utente

Actox
Actox ABE10KFX Manuale utente

Actox
Actox ABEN16KX Manuale utente

Actox
Actox ABE25X Manuale utente

Actox
Actox ABCN50X Manuale utente

Actox
Actox ABE10UKA Manuale utente

Actox
Actox ABC40DC Manuale utente

Actox
Actox ABEN25KX Manuale utente

Actox
Actox ABE10KXHM Manuale utente

Actox
Actox ABC40SKX Manuale utente