Holiday mode
Hold mode
In holiday mode, the T6100 will maintain the set temperature unl the holiday me ends.
In normal med power ‘ on ‘ mode, press to enter seng.
Press △or ▽ to select holiday.
Press to enter holiday days set.
Press △or ▽ to set holiday days .
Press to enter holiday temperature seng.
Press △or ▽to set the holiday temperature.
Press for confirmaon.
Note: Set the holiday days to zero or double press to cancel holiday mode.
The T6100 will maintain the ‘ hold temperature ‘ unl the hold period ends.
In normal med power ‘ on ‘ mode, press to enter seng.
Press △or ▽ to select hold.
Press to enter hold ON/OFF.
Note: Set hold OFF or double press to cancel hold mode.
The weekly circulaon digital programming mode of T6100 is highly free. It uses 7 days as a circulaon. The
parameters are the same from Monday to Friday, Saturday and Sunday can be set separately.
Press △or ▽ to set Hold ON.
Press to enter hold temperature seng.
Press △or ▽ to set the hold temperature.
Press to confirm.
07 08
In normal med power ‘ on ‘ mode, press to enter seng.
Press △or ▽ to select edit.
Press to enter day selecon.
Press △or ▽ to select the day to be set.
Press to enter period selecon.
Press △or ▽ to select the period to be set.
Press to enter start me set.
Program parameter setting