Adronic X56 Manuale utente

User Manual A.0
Please read the user manual carefully
before using this system
For A Better Inspection Scope
X56

WARNING ! Warning: Might influence human security.
NOTE Note: Need to be noticed
Caution: Might cause to the system or device damage.
CAUTION
WARNING
This user manual will indicate the specification, operation, and maintenance
for X56 endoscope system. Please follow the instruction to quickly understand
the correct usage, secure maintenance, and avoid risks. Also please pay
For A better Inspection Scope
attention to the“WARNING”before reading the user manual.
Warning Mark Instruction
Please read this manual carefully to learn the system assembly process,
properly operation and safety precautions before using.
Non-trained or Non-professionals do not operate this system.
Or our company would not be responsible for any accident if occurred.
Our device has electric leakage protection design. Please do not
operate the device with wet hand to avoid electric shock.
Before power on or during operating the connecting probe, pleasei
While operating; please make sure to hold the device tightly to avoid
damage or hurting users caused by falling off.
do not toward to the user’
Please power off the device every time once finished work.
This product does not have consumable materials. If the device has any
damage, please contact with the dealer to issue the defects returning
process.
Please do not use our device to work with other non-standard
accessories. If occurs any damage, our company would not take any
responsibility.
Please follow the instruction strictly; Otherwise, manufacture would not
take any legal responsibility.
If you have any question or need immediate assistance, please contact
A.0
s eye or look at the light source directly.
with product dealer.

X56 Manual
01.Introduction 01
02.Main Device and Accessory 01
03.Scope Function 02
04.Monitor Key Instruction 03
05.Operation Instruction 04
5-1 Video Mode 04
5-2 Play Mode 06
5-3 Setup Mode 08
06.Specification 10
07.Mark Instruction 10
08.Preventive Examination 10
09.Product Cleaning and Maintenance 11
10.Declaration 11
11.Attention 11
12.Application 12
13.FAQ 13
Content
0
User

For A better Inspection Scope
01
01.
X56 endoscope system is mainly used for inspection, repairing and
maintenance. Within 3.5”digital LCD monitor, this unit could connect
The screen is clear and stable, also could manually adjust the image
Introduction
A.0
02. Main Device and Accessory
X56
Q-Tip Cleaning Cloth
with a variety of inspecting probe to display the high quality image.
Power Charger USB Cable 4GB Micro SD Card
size and illumination. X56 enable to support Snapshot, Audio and Video
recording to enhance the detection performance.

02 A.0
X56 Manual
03. Scope Function
Indication Light : Charging
Indication Light : DCIN
Indication Light:Power/SD Card Detection Light
Power On/Off
ESC Key
Downward Key
Upward Key
OK Key
Light up key
Light down key
Video Recording Key
Snapshot Key
SD CARD Slot
RESET Key
USB
DCIN
TV-OUT
1/4”-20 pitch machine screw stud
1
18
6
9
11
12
13
14
15
16
17
18
17
16
15
14
13
12
11
10
2
3
4
5
6
7
8
9
User

0
For A better Inspection Scope
04. Monitor Key Instruction
Button Video Mode Play Mode Set up Mode
Zoom in
(Magnification cycle
from small to large)
X1、X2、X4、X6、X8
Check the photo or
Video saved in SD card
(Enter Play Mode)
Zoom out
(Magnification cycle
from large to small)
Stop Video
Zoom out
Move selection to
the lower one
Play/ Pause Video
Zoom in
Move selection to
the upper one
Enter Setup menu Enter Setup menu Execute the
selected function
Back to Video Mode Exit the menu
Check backward
photo or Video
Left key
(Display model
version for 2 sec.)
Check forward photo or Video Right key
Take photo
Start / Stop Video recording
LED illumination increasing
LED illumination decreasing
03
/
/
/
/

04 0
X56 Manual
05. Operating Instruction
5 - 1 Video Mode
( Preview Mode )
•Video Menu:
key to enter;PressPress to exit ;Press key to select item./
(Video Mode) Sound
Selecting Item
Sound
Grid
Mirror
Factory Set
Function
1.On 2. Off
1.On 2. Off
1.On 2. Off
1.Brightness 2.Contrast
Remark
Fine adjust image color
User

05 0
For A better Inspection Scope
(Video Mode) Mirror
(Video Mode) Factory Set
1. Press key to execute setting, then press key
to select “Brightness” or “Contrast”.
2. key to adjust the value of parameter.Press /
3. Press key to confirm setting.
4. key to exit setting.Press
(Video Mode) Grid

06 0
X56 Manual
05. Operating Instruction
5 - 2 Play Mode
Under “Video Mode”→ Press key to enter “File List Preview”
→ Press / key to select the file
(Photo File *.jpg) (Video *.avi)
1. Press
2. Press
3. Press
4.
key : Zoom in.
key : Zoom out.
key : Browse backward
key : Browse forwardPress
1. Press
2. Press
3. Press
4. Press
5. Press
6. Press
key again: Pause video.
key: Stop video.
key: Speed up playback.
key: Rewind function.
key: Forward function.
→ Press key to check the file.
photo or Video.
photo or Video.
key: Play video.
User

07 0
For A better Inspection Scope
(Play Mode) Slide Show Play Mode) Thumbnail
(Play Mode) DeletePlay Menu
(Play Mode) File List Image Details (Play Mode) Volume
• Play Menu
Press
key → Enter “File List Preview” → Under “Preview Mode”
key twice → Enter “Play Menu”.to select any photo or Video → Press
Selecting Item
Delete
Slide Show
Thumbnail
Volume
Function
1.Single 2. All 3. Select
1.3 Sec. 2. 5 Sec. 3. 10 Sec.
1.Execute 2. Cancel
1.Execute 2. Cancel
Level 1~8
Remark
This function could be
executed when the file
number is more than 2.
Default : Level 8
File List