- 5 -
www.advateklights.com PixLite 16 Plug And Play Mk2 User Manual V211013
3 - Safety Notes
3.1 - AC Power & Opening Enclosure
Inside the fully assembled enclosure there are high voltage hazards. Extreme care
must be taken if opening the enclosure as there are exposed high voltage terminals
inside.
The enclosure lid can easily be opened by removing the 4 large screws located at
each corner (ensure the appropriate sized driver is used or the screw head will get
damaged). The lid may be completely removed allowing full access to the circuit
board, wiring and power supply inside.
3.2 - Air Vents & Temperature Monitoring
The enclosure has two large air vents located on each side which allow the enclosure
to equalize to a low, stable running temperature. One vent is for the air intake and the
other expels the hot air generated from the internal power supply. It is critical to
ensure these vents are not blocked or obstructed by anything while the controller is in
operation. Anything restricting the flow of air out of the enclosure may cause it to
overheat and could damage to internal components.
Due to the nature of the power supply, the internal temperature of the enclosure MUST
be considered. As your load (number of pixels) increases, the power supply will
generate more heat. There is a measured temperature that can be read from the
Advatek Assistant for your convenience, as a rough guide for the power supply's
temperature. The operating temperature of the controller depends, therefore, on the
temperature of the power supply, which is largely dependent on how much power
you are drawing from it, and less dependent on the temperature outside the
enclosure.
Refer to Section 8.1 for more information.