Electrical Connection
Electrical installation must be performed by a qualified electrical technician and comply with
applicable local codes. The motor must have overload protection set to the correct motor
amperage.
Most electrical technicians/contractors will be able to supply motor starter panel or install
motor contactor in cnc machine electrical panel.
Aeroex offers a selection of motor starter panels as listed below:
Start/stop, overloads, no
pilot light
Remote control with 24
VDC signal
Fused disconnect switch,
overloads, pilot light.
Fused disconnect switch,
start/stop,
NEMA 4X enclosure.
Fused disconnect switch,
start/stop,
overloads, pilot light.
Mount the motor starter control panel in a convenient location.
Machine mounted mist collectors can be wired into the CNC electrical control.
Connect electrical wires on dual voltage motors (230/460/3/60) according to wire numbers on
the motor data plate or the motor manual.
Direction Of Rotation
External Motor: (ARO-600)
- Motor direction arrow is located on the motor
- Start/Stop motor
- Check rotation direction
- If incorrect, switch 2 electrical connections, i.e. L1 & L2 (3 phase only)
- Recheck