1. INTRODUCTION
● Main parts of the ventilation unit
● System description
● General safety instructions, guarantee and liability
● Adroit digital controller
● Starting up and shutting down the unit
2. DEPLOYMENT WIZARD
● Basic settings (setting the language, time and date)
● Expert settings (setting the password and access rights, parental controls, fan
settings, prole settings)
3. USING THE UNIT
● Ventilation proles
● Temperatures and sensors
●
Settings (lter, display settings, time and date, week clock, turning the unit off)
4. MAINTENANCE
● Filters
● Heat recovery cell
● Fans
● Condensing water
● Troubleshooting
5. TECHNICAL SPECIFICATIONS
● Technical specications, input powers, air volumes, sound values, fan curves,
dimensions, duct outlets and measurement points
● Internal electrical connection
● External electrical connection
6. INSTALLATION
● Installation site and mounting
● Measuring tubes
● Dimensions and duct outlets
● Condensing water outlet
7. EXPLODED VIEW AND PARTS LIST
8. USER LEVEL DIAGRAMS
9. CERTIFICATE OF CONFORMITY
10. COMMISSIONING THE SYSTEM
11. WARRANTY
4
9
17
28
33
38
41
42
43
44
44
NOTE:
You can sign into your Adroit account at: www.airowadroitcontrol.com

4
DV50 DV80
INTRODUCTION
MAIN PARTS OF THE VENTILATION UNIT
INTRODUCTION
SUPPLY AIR FAN
EXTRACT AIR FAN
OPTIONAL POST-HEATER 900W
HEAT RECOVERY CELL
OUTDOOR AIR FILTER F7
OUTDOOR AIR FILTER G4
EXTRACT AIR FILTER G4
R model in the gure
AUTOMATIC SUMMER/WINTER DAMPER
SAFETY SWITCH
ADROIT DIGITAL CONTROLLER
ADROIT CO2TRANSMITTER
ADROIT HUMIDITY TRANSMITTER
NOTE For more detailed instructions, go to www.airow.com

5© Airow • We reserve the right to make changes without prior notice
DV50 DV80
INTRODUCTION
INTRODUCTIONINTRODUCTION
SYSTEM DESCRIPTION
Router
WLAN/
LAN
WLAN
%
away
from
home
Adroit Cloud
Adroit Adroit Control
Adroit Home
WLAN
INTERNET
WLAN / LAN
SENSORS
EXTERNAL
SWITCHES
ROUTER
MODBUS
HOME
AWAY
BOOST
WOOD
BURNER
CONNECTING WITH ADROIT HOME
1. Connect Adroit unit to the mains.
2. Connect one end of the network cable (RJ-45) to computer and
the other end to network connector on the Adroit unit.
3. Select on your computer: Start ►Computer ►Network
4. Double click on the Airow icon.
5. Now you are connected to the Adroit Home service, you are able
to control the Adroit unit.
REGISTERING TO THE ADROIT CLOUD
1. Connect with Adroit Home (instruction above).
2. Select Settings.
3. Press connect button in Adroit Cloud Service section.
4. Registration Page is now opened.
5. Enter the following information
a. Device name- enter the desired name for the device
b. User name
c. E-mail address
d. Password
6. Press the create account button.
7. An e-mail with your log-in details will be sent to the e-mail given
during the registration process.
8. A verication e-mail will be sent to the e-mail address given
during the registration process.
9. Click on the link given in this e-mail to verify your e-mail address.
10. You are now connected to the Adroit Cloud.
NOTE
Following requirements:
Firefox, version 31 or higher
Opera, version 25 or higher
Chrome, version 31 or higher
Safari, version 7 or higher
The lastest browser versions on
mobile devices.
NOTE
The Adroit unit can also be
connected by network cable to a
router. In this case the Adroit unit
can be controlled via your laptop,
tablet, smartphone etc using a
network created by the router.

6
DV50 DV80
INTRODUCTIONINTRODUCTION
INTRODUCTION
GENERAL SAFETY INSTRUCTIONS
For safe and proper handling, it is necessary to know the basic
safety regulations and the intended usage of the ventilation system.
Read this manual before operating the ventilation unit. Keep this
manual for later use. In case of loss, you can download the manual
from our website.
This user manual contains all important tips for operating the
system safely. This user manual must be observed by all persons
who operate and maintain the ventilation system. Furthermore,
observe all local accident prevention regulations.
INTENDED USE
All Adroit ventilation units have been designed to provide
appropriate and continuous ventilation in such a way that people
and structures will remain healthy..
GUARANTEE AND LIABILITY
• Demands on guarantee and liability are excluded if they are
caused by the following reasons:
• Unintended use of the ventilation system and the control unit
• Improper mounting, initial operation and operation
• Operating the ventilation system with a defective safety
system
• Ignoring advice for transportation, mounting, operation and
maintenance
• Unauthorized structural alteration and changes of the
programming
• Disasters due to extraneous elements and force majeure
INSTALLATION
Installation and setup should be carried out only by qualied
experts. Electrical installations and connections must be carried out
only by an electrician and in compliance with local regulations.

7© Airow • We reserve the right to make changes without prior notice
DV50 DV80
INTRODUCTION
INTRODUCTION
Change prole button changes the ventilation prole or the operating status
used.
Prole Information button allows you to view the currently active prole
information.
Temperature button displays temperature and sensor information.
Settings button opens the settings.
Back button takes you backwards in the menu.
Left arrow button takes you left in the menu.
Right arrow button takes you right in the menu.
OK button accepts the selected option.
Select button selects an option from the list.
Edit allows you to edit settings.
Plus allows you to:
• Increase the value of the selected setting.
• Move to the next menu item.
• Move from a one-day view to a week view in the temperature, relative
humidity of air and carbon dioxide level graphs.
Minus allows you to:
• Reduce the value of the selected setting.
• Return to the previous menu item.
• Move from a week view to a one-day view in the temperature, relative
humidity of air and carbon dioxide level graphs.
Up arrow button takes you upwards in the menu.
Down arrow button takes you downwards in the menu.
Statistics button opens the temperature, relative humidity of air and carbon
dioxide level graphs (1 day or 1 week).
These icons indicate the hierarchy level of the settings.
This icon indicates when the feature is turned off at your user level. The
parental controls lock code is 1001.
BUTTON DESCRIPTION
NOTE
The Adroit Digital Controller contains
the buttons described in the following
table. You can press the graphical
user interface buttons by using the
ring-shaped buttons below the control
panel. The control panel does not
have a touch screen.
ADROIT DIGITAL CONTROLLER

8
DV50 DV80
INTRODUCTION
INTRODUCTION
INTRODUCTION
Ventilation has to be constant for the indoor air to stay healthy for
the dwellers and the structures of the dwelling. Even for longer
holidays, it is not advisable to stop the ventilation, because the
indoor air will become stuffy and, during the heating season, the
indoor air humidity may condense in the ventilation ductwork and
structures, causing moisture damage.
You can control and automate the ventilation unit operation in the
following ways:
• By using a control panel installed in the building
• Through the Home local network connection and the Web
interface
• Through the Adroit Cloud Service and the Web interface
• Through a remote monitoring service or building automation
by using voltage signals or Modbus messages
The required ventilation may also be adjusted automatically with
the optional carbon dioxide and humidity sensors. In this case,
ventilation remains optimal even if the dwelling is unoccupied.
By using the week clock, you can create just the right ventilation for
your individual lifestyle.
The following settings will be congured during the setup of the
ventilation system:
• user interface language
• time and date
• system administrator password
• parental controls, if turned on
• fan settings
• user prole settings, such as the temperature.
The qualied ventilation installer must complete the fan settings in
accordance with the ventilation plan. Do not change these settings.
STARTING THE UNIT
If you are starting the ventilation unit for the rst time or after a
maintenance procedure, rst connect it to the mains. During the
start-up, the diagnostics display will appear for a few seconds, after
which the main display of the At home prole opens.
If the ventilation unit was turned off from the control panel (see
Turning the Unit Off), you can start it by pressing any control panel
button.
WARNING
The unit is not intended for use
by children under 8 or by persons
with reduced sensory, physical or
mental capabilities, or whose lack of
knowledge and experience do not
ensure safe operation of the unit.
Such persons can use the unit
under supervision, or by following
the instructions of someone who is
responsible for their safety.
TIP
The Adroit Digital Controller
automatically switches to the sleep
mode when the Sleep time set in the
Display settings has elapsed. You can
wake up the control panel by pressing
any control panel button.
NOTE
The rst starting of the unit may take a
while, because of the software version
check.

9© Airow • We reserve the right to make changes without prior notice
DV50 DV80
BASIC SETTINGS
DEPLOYMENT WIZARD
SWITCHING THE UNIT OFF
If you want to switch off the ventilation unit, proceed as follows:
1. Select Settings > Turn unit OFF.
2. Press the OK button.
3. The system asks for conrmation.
4. Press the OK button.
5. The ventilation unit is now switched OFF.
NOTE
However, it is recommended that the ventilation be kept turned ON
without disruptions.
DEPLOYMENT WIZARD
1. Start the Adroit ventilation unit.
2. Press the OK button.
3. The deployment wizard is launched.
SELECTING THE LANGUAGE
1. Use the arrow buttons to select the language.
2. Select OK.
3. The language has now been set, and the control panel will
move on to the time settings.
SET THE TIME
1. Use the Plus and Minus buttons to set the hours.
2. Select Right arrow.
3. Use the Plus and Minus buttons to set the minutes.
4. The time is now set.
5. Proceed to the next phase by selecting Right arrow.

10
DV50 DV80
DEPLOYMENT WIZARD
BASIC SETTINGS
SET THE 24 OR 12 HOUR CLOCK
By default, the system uses a 24 hour clock.
If you want to use the 24 hour clock, proceed to the next step by
pressing the Arrow right button.
If you want to use the 12 hour clock, proceed as follows:
1. Press the Minus button. The 24-Hour Time setting value is
changed to Off.
2. Proceed to the next phase by pressing the Right arrow button.
SET THE AUTOMATIC DAYLIGHT SAVING TIME
By default, the system automatically switches to the summer time.
If you want to use the automatic daylight saving time, proceed to the
next step by pressing the right arrow button. If you want to use the
manual daylight saving time, proceed as follows:
1. Press the Minus button. The Daylight Saving Time setting
value is changed to Off.
2. Manual daylight saving time is now set.
3. Proceed to the next phase by pressing the Right arrow button.
SET THE DATE
1. Use the Plus and Minus buttons to set the date.
2. Select Right arrow.
3. Use the Plus and Minus buttons to set the month.
4. Select Right arrow.
5. Use the Plus and Minus buttons to set the year.
6. Select OK.
7. The date is now set.
NOTE
You can browse the Time and date
settings by using the Right arrow button.
FINISHING UP THE DEPLOYMENT
When you have made the basic settings for the deployment, the
acknowledgement screen is opened.
If you want to continue and make the advanced settings for the
ventilation device, press the OK button.
If you want to intermit the deployment and use the ventilation device
on factory settings, press the Back button: You can make the expert
settings for the ventilation device later.
IMPORTANT
Some deployment phases require special equipment, such as an air
ow meter