AirQM AirQM-9 Manuale utente

AirQM-9 Instruction Manual
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.

Product Introduce
Face Panel
Specifications:
Model
AirQM-9
Size
150*66*49.2mm (non-include power plug)
Net Weight
Input Power
110~240V-0.1A, 50/60Hz
Operation Ambient
Indoor Use Only
Temp:-10℃~60℃Hum: 0-90% non-condensing
Network Connection
Wi-Fi IEEE 802.11b/g/n 2.4GHz
Status Indicator
LCD Display
Ambient light sensor
Switching Button

Operations
Configuration
Enter Network Configuration Mode
Press the Switching Button for several
seconds after power on, and release the
button after buzzer is on. The Wi-Fi icon
should flash slowly in the upper right
corner of the display, then the device
enters the network configuration mode.
Flash slowly
Setup
Insert the device to the power socket
and the display show a ten-second
countdown. The device starts to work
normally when the countdown end.
⚫Attention:
To ensure the data accuracy of the
measurement, please keep the
device’s orientation as the picture
and working in a well-ventilated
place.

Connect the Device with Mobile
phone
Enter WLAN setting of mobile
phone, search Wi-Fi ‘airbox_device’
and select.
Enter Network Configuration Interface
After the mobile phone is connected to the
device’s Wi-Fi, open the phone browser
and input 192.168.4.1 in the address bar to
enter configuration interface.
Fill in the Configuration Information
Input Wi-Fi SSID, password and other
network configuration parameters in the
Connect NetWork interface. And click
the Config button to finish.
*
*

Display Description:
⚫Attentions:
1. Special characters are not allowed when entering the
configuration information.
2. The mark *are mandatory field, please fill in correctly.
3. The last input data will be the default configuration if the non-
mandatory fields are not modified when changing the network
connection setting.
Measuring Type
Measurement Data
Unit of Measurement
Measuring Type Switching
The Display just can show one
measurement data only, click the
Switching Button to change the
display parameter.

Status Indicator Description:
●18℃~35℃, Green
●Out of range, Yellow
40%~85%, Green ●
Out of range, Yellow●
●30~500lux, Green
●Out of range, Yellow
●Less than 500ppm, Green
●500~1500ppm, Yellow
●More than 1500ppm, Red
Less than 1500ppm, Green ●
1500~3000ppm, Yellow ●
More than 3000ppm, Red ●
●Less than 50μg/m³, Green
●50 ~100μg/m³, Yellow
●More than 100μg/m³, Red
Less than 80dB, Green●
More than 80dB, Yellow●
Temperature
Humidity
Illuminance
Noise
Smoke
Carbon Dioxide
Particulate Matter 2.5

⚫Attention:
When the measuring value of CO, CO2 or Smo are out of range, the
Status Indicator light up in red and buzzer alarm.
●Less than 5ppm, Green
●5~35ppm, Yellow
●More than 35ppm, Red
Less than 1.0ppm, Green ●
1~3ppm, Yellow ●
More than 3ppm, Red ●
Carbon Monoxide
Volatile Organic Compound

FCC Warning Statement
Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment. This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
‐‐ Reorient or relocate the receiving antenna.
‐‐ Increase the separation between the equipment and receiver.
‐‐Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
‐‐ Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
RF Exposure Statement
To maintain compliance with FCC's RF Exposure guidelines, This equipment should be
installed and operated with minimum distance of 20cm the radiator your body. This device
and its antenna(s) must not be co-located or operation in conjunction with any other
antenna or transmitter.
Indice