Alarmcom ADC-SEM300 Manuale utente

S M-Honeywell/AD MCO Vista Dual-Path (S M300) - Installation
Guide
925-00002-001 Rev A
Alarm.com Dual-Path System nhancement Module (S M) is the most cost-effective and comprehensive solution to
migrate compatible Honeywell/AD MCO VISTA-10P, VISTA-15P, and VISTA-20P panels to Alarm.com’s award-winning
interactive services. The Dual-Path S M supports the 4G LT cellular network and optional Broadband thernet. This
ensures the longest life cycle with the most secure and reliable service.
Equipment
System nhancement Module
Installation guide
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
1

Panel compatibility
Important: For remote programming to be available, the panel must support the downloader feature. This feature is
available on most panels with a minimum revision of v5.2. For the most up-to-date list of compatible panels, see S M-
Honeywell/AD MCO Vista Dual-Path - Troubleshooting Guide.
The S M is compatible with Honeywell/AD MCO Vista-10P, -15P, and -20P panels and the equivalents below, dating
back to 2005. The Honeywell/AD MCO VISTA-21iP is also compatible when the Internal IP/GSM jumper switch is set to
the OFF position.
Panel Compatibility
Honeywell/AD MCO Vista-10P
• Honeywell/AD MCO Vista-10PSIA
• First Alert FA130CP
• First Alert FA130CPSIA
Honeywell/AD MCO Vista-15P
• Honeywell/AD MCO Vista-15PSIA
• First Alert FA148CP
• First Alert FA148CPSIA
Honeywell/AD MCO Vista-20P
• Honeywell/AD MCO Vista-20PSIA
• First Alert FA168CPS
• First Alert FA168CPSSIA
Honeywell/AD MCO Vista-21iP Compatible when the Internal IP/GSM jumper switch is
set to the OFF position.
Recommended tools and supplies
Note: These are not included.
• Screwdrivers: Small blade and Phillips
• Drill and bits for screws and/or wall anchors
• thernet cable
• Alpha keypad (not required)
◦ Alarm.com strongly recommends installing an alpha keypad to ensure the failure to communicate (FTC) trouble
condition is displayed to the user. See FAQs for more information.
• Four-conductor, 22 AWG or larger stranded wire
The following table shows the maximum wire length for each gauge.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
3

Gauge Maximum wire length
22 gauge 40 feet (12.2 m)
18 gauge 90 feet (27.4 m)
Prepare the system
Before powering down the system:
Verify panel compatibility
Verify that the panel is compatible by checking the version and year printed on the PROM chip inside the panel
enclosure.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
4

Execute *96
nter programming and execute *96 to reset the account number and initialize the downloader. Then, exit programming
via *99.
Enable the keypad address
The default keypad address the S M uses is Keypad 8 Device Address 23. If this keypad address is disabled, the S M
and panel will not communicate properly. However, at first power-up, the S M will attempt to enable this address
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
5

automatically. If unsuccessful, the address must be enabled manually via programming *196.
If another keypad is occupying this address already, a different address must be selected for the S M. To select a
different keypad address, manually adjust the dual in-line package DIP switches on the S M to match the desired
keypad address listed below. Then, exit programming via *99.
For additional information about enabling the keypad address, see What keypad address should be used with the S M-
Honeywell/AD MCO Vista?.
Keypad address DIP switch setting VISTA programming command
17 None—all OFF *190
18 Switch 4 ON, others OFF *191
19 Switch 3 ON, others OFF *192
20 Switch 3 and 4 ON, others OFF *193
21 Switch 2 ON, others OFF *194
22 Switch 2 and 4 ON, others OFF *195
23 Switch 2 and 3 ON, others OFF *196
Disarm and power down the panel
1. Verify the panel is disarmed and clear of any alarms, troubles, or system faults.
2. If you do not know the current installer code, check the installer code at the panel before powering down the panel.
3. Then remove AC power and disconnect the backup battery to completely power down the system.
Create an Alarm.com account
1. Create a new Alarm.com customer account using Partner Portal or MobileTech. The IM I located on the
Alarm.com module will be needed to create this account.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
6

2. During the account creation process, you are prompted to enter the current installer code on the panel. Alarm.com
uses this code to access panel programming and read information stored on the panel.
3. At the end of the Create New Customer process, you are able to print or email a Welcome Letter for the customer,
which includes login information for the Alarm.com Customer Website.
For more information about creating a customer account, see How to create an Alarm.com customer account.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
7

After powering down the system:
Remove third party communication
If there are any third-party communicators installed or a POTS line connected to the panel, remove them.
The S M is not compatible with POTS, IP/GSM devices, or other third-party communicators. Therefore, the S M should
be the only communication device installed for alarm signaling to the monitoring station.
Inspect for peripheral devices
1. Take inventory of all peripheral devices (wireless receivers, zone expanders, keypads, power supplies, etc.) wired
to the system.
2. Inspect the wiring to verify there are no loose ends or intermittent connections between the device and system.
The presence of peripheral device issues can often cause the S M installation process to take longer than
expected.
Connect the SEM
Mounting
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
8

Before mounting the S M to the wall:
1. valuate how the wiring cables will be routed from
the S M to the panel.
2. Remove the snap-off plastics. There are two
routing options available: the side of the enclosure
for side routing or the rear of the enclosure for wall
routing.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
9

To mount the SEM:
1. Press in on the thumb tabs located at the bottom of
the enclosure, then swing up the top half of the
enclosure cover to expose the internal
components.
2. Place the S M enclosure back plate against the
wall at the desired mounting location and mark the
four mounting holes.
3. Using the provided mounting screws and wall
anchors (if needed), place the first mounting screw
through the top-right enclosure hole. This screw
will be used to hang the S M from the wall while
mounting and should not be tightened until the last
step.
4. Place the second mounting screw through the
bottom-left mounting hole. This screw is used to
level the enclosure on the wall and should not be
tightened until the last step. A standard leveling
device may be used to ensure the unit is level.
5. Place the third mounting screw through the top-left
enclosure hole. This screw should be tightened
fully against the unit and wall before moving to the
next step.
6. Place the final mounting screw through the bottom-
right enclosure hole. This screw should be
tightened fully against the unit and wall before
moving to the next step. Note that this screw is
critical for the wall tamper functionality and should
not be overlooked.
7. Tighten the first two mounting screws fully to the
unit and wall to complete the mounting process.
Wiring
Important: Alternate wiring is required when using this device for TL installations. For more information, see TL
requirements.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Panels/S M_Honeywell_AD MCO_Vista/S M-Ho…
Updated: Thu, 27 May 2021 18:46:08 GMT
10
Indice
Altri manuali Alarmcom Hardware di rete
Manuali Hardware di rete popolari di altre marche

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuale utente

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuale utente

Yudor
Yudor YDS-16 Manuale utente

D-Link
D-Link ShareCenter DNS-320L Manuale utente

Samsung
Samsung ES1642dc Istruzioni per l’uso

Honeywell Home
Honeywell Home LTEM-PV Istruzioni per il montaggio