Alert-it Companion Mini Manuale utente

LESS STRESS CARING
Companion
Mini
Connect
HANDBOOK

Your product has been manufactured
by a team of industry experts with
more than 20 years of experience
designing, manufacturing and
distributing care alarms.
With a commitment to quality and innovation we
are able to bring you a robust and reliable system
to aid carers with the detection of seizures and the
safeguarding of individuals. Please read this guide
carefully to ensure the correct set up, use, and
maintenance of your new product for years to come.
If you have any questions or require assistance in
regards to the Companion mini, Connect-iT or any
other Alert-iT product, our experienced team are on
hand to help. Please nd contact details below.
Don’t forget you can also join us on Facebook,
Twitter and LinkedIn where you’ll nd even more
information and advice.
Call: 01530 239 900
Social:
AlertitCareAlarms
Alert_iT_Care
Alert-iT
or join our supportive Epilepsy Forum
Congratulations on your Alert-iT purchase 2

Product Information 5
In The Box 6
Quickstart 7
Using the device with a 3rd party radio module 7
Companion mini Function 10
Device Installation 10
Turning on the Companionmini (Monitor) 10
Postioning and Setup 11
System Operation 12
Maintenance Instructions for the mini 14
Connect-iT Function 15
Turning the Connect-iT on
Pairing
Clearing the Memory
Function 16
Front panel Lights
Wired Output
Resetting an Alarm (Excluding the Companion mini)
Common Fault Conditions
Alarm Conditions 17
Normal Alarms
Mounting the unit to a wall
Removing the Connect-iT from Service
Contents
Continued Overleaf
3

Installation 18
Nurse Call Cables/Leads 19
Leads available from Alert-iT
Wired Output Specification
Advanced Options 20
Maintenance Instructions for Connect-iT 21
Routine Testing of the Backup Battery
How to Clean the Device
Additional Info 22
Third Party Radio Transmitters 22
Troubleshooting 23
Warranty Information 24
Companion mini Specification 25
Certification 25
Connect-iT Specification 26
Certification 26
Routine Test Sheet 27
Profiler Editor Software 29
Product Information 31
Contents 4

The Companion mini provides peace of mind for carers and individuals
who have epilepsy.
This product has been designed to discreetly monitor the user with high performance
sensors which identify movements that could indicate a seizure.
The monitor can help to indicate the following seizure types:
`Tonic-clonic
`Partial
`Generalised
The Companion mini is paired to the Connect-iT via Alert-iT’s failsafe “Safelink®” radio
system. Upon detection of an alarm condition the Companion mini alerts the Connect-iT,
which in turn triggers a nursecall point or internally tted 3rd party radio board.
The Connect-iT will normally be powered from a mains adapter, but it features a battery
backup that provides over 24 hours of power in case of a power cut.
The Companion mini is a battery powered device with a 1 year battery life.
Product Information 5

In The Box 6
The Companion Mini Pack Contains:
A 1 x Companion Mini - P176A (C0) Includes 2 x AAA Non-rechargeable Batteries
B 1 x Foam Block
C 1 x Companion Mini Mounting Kit
D 1 x Connect-iT - P155B MKII Includes 2 x AA Ni-MH Rechargeable Batteries
E 1 x 12v Power Supply - P171
F 1 x Wall Mounting Kit (Not Shown) 2 x Wall screws + Wall plugs / 2 x Sticky pads
A C
E
B
D
PLEASE NOTE:
Nurse Call Leads are not included and are provided
separately. See page 19 for further details.

Quickstart 7
`Unpack box
`Turn on the Companion mini by pressing the recessed
“Test” button with a pen tip
`Place the mini under the bed
`Press the “Pair” button on the Connect-iT to turn it on
`Plug the P171 Power Supply into a mains socket,
then plug the other end into the socket labelled
“12v DC”. (The green “Power” LED should turn on)
`Plug the red end of the nurse call cable into the
socket labelled “Output”
`Plug the other end of the nurse call cable into the
nurse call point
`Pair the Connect-iT with the 3rd party pager as
described in their manual.
See page 22 for more details
Using the device with a nurse call point
Using the device with a 3rd party radio module
Figure 1
Figure 2

Quickstart 8
`Now ensure that the “Monitor” LED ashes green
every time the radio product transmits (Every 8
seconds for a Safelink enabled product like the
Companion mini)
`Ensure the “Alarm” LED ashes and the Wired output
activates when the monitor is triggered.
See page 16 for details
`Pull out the 12v DC jack to simulate a power cut. The
device should continue to operate as expected on the
battery backup. See page 16 for details of LED status
`Fix the Connect-iT’s back panel to a wall using the
provided screws OR sticky pads
PLEASE NOTE:
We highly recommend screws are used, as the sticky
pads can slowly work their way loose over time
unless the surface is perfectly clean and at
`Clip the Connect-iT onto the back panel
`Route the cables to ensure they do not pose an
entanglement or trip hazard
`You can now return the monitors to their intended
locations and test the system works as expected. i.e
Monitors are within range of each other and trigger
your system/nurse call
Figure 3

Quickstart 9
`As you are paired with a Safelink enabled epilepsy
monitor, the Connect-iT will raise a “Radio Fail” fault
and trigger an alarm if it does not receive any radio
signals for 2 minutes.
`So if the wired output is activating unexpectedly
and the “Monitor” LED is ashing it may be that the
monitor has been turned off.
`The lights and sounds can be disabled by holding the
“Clear” button on power-up. See page 20 for details.
`Please be aware that Nurse Call systems which
do not use a “Normally closed” connection may
not be alerted if the nurse call lead is unplugged or
disconnected. Regular testing must be performed to
ensure system is working as intended.
`It is recommended not to use this system where a
risk Is identied that users are likely to intentionally
remove cables, or intentionally un-pair / tamper
with the monitors, as alarm conditions may not be
annunciated at the carers location.
`Use rechargeable batteries (listed) only!
Using the device with a 3rd party radio module

Companion mini Function 10
Device Installation
Turning on the Companionmini (Monitor)
The Companion mini monitor is shipped in a low-power state.
The monitor is turned on by pressing the recessed ‘Test’ button on the front of the monitor (Figure 1), typically
using a pen tip. The monitor will rst enter a 60 second test mode.
When the “Test” button is pressed the internal red light will ash to indicate the unit is now turned on and in test
mode. After 60 seconds the light will stop ashing and the test mode will end.
This test mode exists to allow the user to easily test the positioning of the monitor under the bed. While in test
mode, every time the monitor detects movement, it sends out a radio signal to the Connect-iT.
Figure 4
Altri manuali per Companion Mini
2
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Alert-it Monitor