Allegion Interflex IF-4070 Manuale utente

IF-4070 Controller
Controller
00-4070-00xx

Table of contents
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 2
Table of contents
1 General information.......................................................................................................................... 3
1.1 Short description ......................................................................................................................... 3
1.2 Scope of delivery ........................................................................................................................ 3
1.3 Intended use ............................................................................................................................... 3
1.4 Target group ............................................................................................................................... 3
1.5 Safety.......................................................................................................................................... 4
1.6 Abbreviations .............................................................................................................................. 4
1.7 Cable lengths and cable types.................................................................................................... 5
2 System overview............................................................................................................................... 6
2.1 Range of functions ...................................................................................................................... 7
2.2 Electronic assembly units ........................................................................................................... 7
2.3 IF-4070 controller overview......................................................................................................... 8
3 Mounting the controller.................................................................................................................... 10
4 Connecting the controller ................................................................................................................ 11
4.1 Removing the housing lid............................................................................................................ 11
4.2 Wiring components ..................................................................................................................... 11
4.3 Connecting the power supply...................................................................................................... 14
5 Initial operation ................................................................................................................................. 15
5.1 Connecting the controller to the network .................................................................................... 16
5.2 Checking and setting network parameters.................................................................................. 18
5.3 Configuring the interfaces and the booking memory .................................................................. 20
5.4 Listing the configuration data of readers..................................................................................... 21
5.5 Restarting the controller.............................................................................................................. 22
6 Updating the software ...................................................................................................................... 24
7 Upgrading the controller.................................................................................................................. 25
8 Technical specifications .................................................................................................................. 25
9 Disposal............................................................................................................................................. 26
10 EU Declaration of Conformity.......................................................................................................... 26

1 General information
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 3
1 General information
1.1 Short description
The controller IF-4070 serves as the connecting link between a maximum of 16 Interflex readers for time
& attendance recording or access control. Eight integrated relays and eight input contacts allow for the
control and monitoring of doors, for example. The controller is available in four different versions which
support two, four, eight or sixteen terminals.
1.2 Scope of delivery
nIF-4070 controller
n2 housing brackets for mounting into 19” cabinet
n2 retaining brackets for hooking into 19” cabinet
nAccessory bag with mounting parts
n9510425 product info
Check the completeness and condition of the goods upon receipt and report any damage caused
during transport immediately.
1.3 Intended use
Controllers of this series are designed for fixed installation in dry rooms.
Any other use is not in accordance with the intended purpose and therefore not permitted. Modifications
to the device are not permitted.
1.4 Target group
This document is solely intended for experts and people trained in electrical engineering.

1 General information
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 4
Only perform the actions described in this document if you belong to this target group. Interflex
Datensysteme GmbH is not liable for any damages caused by improper installation or initial
operation.
1.5 Safety
WARNING
Danger to life due to electric shock
People can be seriously hurt or killed through physical contact with live parts (e.g. 230V~).
uMake sure that you cannot touch live lines during installation.
uSwitch off the power supply of the devices.
uPlease observe the applicable safety regulations and take all precautionary measures to ensure safe
installation.
NOTICE
Property damage due to transient overvoltages
Transient overvoltages (surges, bursts) in the energy supply network can lead to malfunctions and
failures.
uUse suitable mains filters that are professionally installed and operated.
NOTICE
Damage due to electrostatic discharge (ESD)
Electrical components and modules can be damaged by only slight, hardly noticeable electrostatic
discharge (ESD) without this becoming immediately obvious. ESD damages result in malfunctions and
even failure of the product.
uMake sure that effective protective measures against electrostatic discharge are in place when
working on the open device.
1.6 Abbreviations
AC Alternating Current
BLE Bluetooth Low Energy
CIDR Classless Inter-Domain Routing
DC Direct Current
DIP switch Switch in IC design, connections in two rows (Dual In-line Package)
EMC Electromagnetic Compatibility
ESD Electrostatic discharge

1 General information
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 5
GND Ground
IEEE Institute of Electrical and Electronics Engineers
NC contact Normally closed contact
NO contact Normally open contact
PoE Power over Ethernet
RFID Radio-Frequency Identification
SH Shield
SSH Secure shell
1.7 Cable lengths and cable types
Cable Function Max. Length Recommended cable type
230 V AC power supply to power supply unit (if not
pre-installed)
NYM 3 x 1.5mm2
Network cabling: RJ45 patch cable, preferably shield
braiding
100 m From category 5
Cable to floating status contacts, control cable 100 m J-Y(St) Y 2 x 2 x 0.6mm2
J-Y(St) Y 2 x 2 x 0.8mm2
RS485 bus cable to parent or child devices 1200 m J-Y(St) Y 2 x 2 x 0.6mm2
J-Y(St) Y 2 x 2 x 0.8mm2
RS485 branch cable to bus cable 100 m J-Y(St) Y 2 x 2 x 0.6mm2
J-Y(St) Y 2 x 2 x 0.8mm2
Connecting cable between I/O controller board and
reader
100 m J-Y(St) Y 4 x 2 x 0.6mm2
J-Y(St) Y 4 x 2 x 0.8mm2
In long cables, voltage losses can impair the functionality of the connected device. Therefore, do not use
cables longer than specified in the table. Wire the +5 V and GND lines with two cores each for a cable
length > 50 m.

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 6
2 System overview
1Controller 1Cable to floating status contacts
2Inputs for floating status contacts 2Control cable
3Relay with 30V, 2A switch contacts 3Power cable (not applicable for PoE)
4Switch or PoE device 4Ethernet without PoE
5Host system 5Terminal bus cable
6Readers for recording time data 6RS485 branch cable from reader to bus cable
7Reader for access control
8Locking device with access control actuator
and status contact
9Readers for recording time data

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 7
2.1 Range of functions
Main functions of the If-407x controller:
Field of Application
The controllers are operated with the IF6020 or IF6040 host system and control up to 16 Interflex readers
for time & attendance recording or access control that are distributed among three RS485 interfaces. The
controllers check the booking data from the readers and transfer it to the host system in real-time.
Furthermore, they control the booking conditions and display texts of the readers.
Offline mode
Data required for offline operation (e.g., credential numbers, temporal and local permissions) is stored in
the controller via the host system. Thus, the data is always up-to-date even if the connection to IF-6020
and IF-6040 is interrupted and can be checked by the controller in offline mode.
Control and Monitoring
For controlling and monitoring doors, for example, the IF-4070 controller is equipped with digital inputs for
the connection of door contacts or other sensors and output relays with a switching capacity of up to 30
V/ 2 A. Thus, external devices can also be controlled. The input sensors can be configured as indicator,
event, or counting contacts (up to max. 20 Hz).
2.2 Electronic assembly units
1Connector for anti-tamper
switch
2Mains filter 250 mA 3Transformer

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 8
2.3 IF-4070 controller overview
Connections on the printed circuit board
7
1235
6
9
10
4
12
11
8
1USB connection (for future use)
214-pin screw terminal for floating status contacts
314-pin screw terminal for floating status contacts and relay contacts
414-pin screw terminal for relay contacts
56-pin screw terminal for relay contacts
6Screw terminal for the connection of the power supply
7RJ45 socket for the connection to the Ethernet network (host system)
8USB connection (for future use or ServiceApp)
93x RJ45 sockets with RS485 interfaces for the connection of bus data cables 1, 2, 3
10 RJ45 socket with RS232 interface for the connection of a service device
11 3-pin screw terminal for RS232 service cable (same function as socket 10)
12 7-pin screw terminal for RS485 data cable (same function as socket 9)

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 9
LEDs and switches
LED Status Operating mode of the controller
Bus 1 / 2 / 3 Lights up Data exchange with reader on bus 1 / 2 / 3
RUN Lights up Application has been started; controller is ready for operation
LINK Flashing Network data exchange
SPEED On (lights up)/ off Network speed: Lights up at 100 Mb / off at 10 Mb
Switch/ push- button Function
Reset Cancel active processes, trigger restart
Kaltst. Delete stored data, restore standard parameters
SW Save IP address settings temporarily and set default IP address to
172.18.70.52.

3 Mounting the controller
© 2021 Interflex Datensysteme GmbH IF-4070 Controller 10
3 Mounting the controller
NOTICE
Damage to property due to manipulation of the controller
Manipulation of the controller can lead to data loss.
uInstall the controller in the secured area, taking the technical requirements into account
With the two enclosed housing brackets, you can mount the controller into a 19” cabinet.
1Housing bracket 2Angle bracket
The illustration shows the installation with housing brackets 1 in a 19” cabinet. The angle brackets 2
allow the controller to be pulled out and hooked into the rack, e.g. to connect cables.
You can also mount the controller onto a wall using the device brackets. Without brackets, the
device can also be placed on a tabletop or even stacked.
Altri manuali per Interflex IF-4070
1
Indice
Altri manuali Allegion Controllori

Allegion
Allegion Interflex IF-4070 Manuale utente

Allegion
Allegion LCN 8310-813 Manuale utente

Allegion
Allegion interflex IF-4077-4 Manuale utente

Allegion
Allegion Interflex IF-4072 Manuale utente

Allegion
Allegion Simons Voss Technologies SmartCD2.G2 Manuale utente

Allegion
Allegion Simons Voss Technologies SmartCD2.G2 Manuale utente

Allegion
Allegion interflex IF-4077-8 Manuale utente

Allegion
Allegion LCN 8310-815 Manuale utente

Allegion
Allegion Interflex IF-4076-4 Manuale utente

Allegion
Allegion 8310816 Manuale utente