Generator exhaust contains high levels of carbon monoxide (CO), a
poisonous gas you cannot see or smell. If you can smell the generator
exhaust, you are breathing CO. But even If you cannot smell the
exhaust, you could be breathing CO.
· NEVER use a generator inside homes, garages, crawlspaces, or other
partly enclosed areas. Deadly levels of carbon monoxide can build up
in these areas. Using a fan or opening windows and doors does NOT
supply enough fresh air.
· ONLY use a generator outdoors and far away from open windows,
doors, and vents. These openings can pull in generator exhaust.
Even when you use a generator correctly, CO may leak into the home.
ALWAYS use a battery-powered or battery-backup CO alarm in the
home.
If you start to feel sick, dizzy, or weak after the generator has been
running, move to fresh air RIGHT AWAY. See a doctor. You could have
carbon
monoxide poisoning.

Thank you for purchasing our generator.
This manual covers the operation and maintenance of the generator.
All the information in this publication is based on the latest product information available at the
time of approval for printing.
We reserve the right to make changes to this manual at any time without notice and obligation
whatsoever.
No part of this publication may be reproduced without written permission from All-Power America.
This manual should be considered a permanent part of the generator and should remain with it
when being resold.
Pay special attention to statements preceded by the following words:
PREFACE
Failure to properly follow these precautions can result in property damage,
serious injury or DEATH!
Read all labels and the owner's manual before operating this generator.
Operate only in well ventilated areas. Exhaust gas contains poisonous carbon
monoxide, and can be deadly.
Always stop the engine before refueling.Wait 5 minutes before restarting.
Check for spilled fuel or leaks. Wait 5 minutes before use.
Keep any sources of ignition away from fuel tank at all times.
Indicates a strong possibility of severe personal
injury or death if instructions are not followed.
Indicates a possibility of personal injury or equipment damage if instructions
are not followed.
NOTE:Gives helpful information.
If a problem should arise or if you have any questions about the generator,
consult an authorized dealer.
3500W Digital Generator
1
Our generators are designed to give safe and dependable service if operated
according to instructions. Read and understand the Owner's Manual before
operating the generator.
Failure to do so could result in personal injury or equipment damage.

CONTENTS
1 SAFETY INSTRUCTIONS ------------------------------------------------------------------------------------3
2 SAFETY LABEL LOCATIONS -------------------------------------------------------------------------------5
3 PRE-OPERATION CHECK -----------------------------------------------------------------------------------8
4 STARTING THE ENGINE -----------------------------------------------------------------------------------11
5 USING THE GENERATOR ---------------------------------------------------------------------------------14
6 STOPPING THE ENGINE ----------------------------------------------------------------------------------17
7 MAINTENANCE -----------------------------------------------------------------------------------------------18
8 TRANSPORTING/STORAGE ------------------------------------------------------------------------------23
9 TROUBLESHOOTING ---------------------------------------------------------------------------------------24
10 SPECIFICATIONS --------------------------------------------------------------------------------------------26
11 WIRING DIAGRAM -------------------------------------------------------------------------------------------27
12 WHEEL KIT -----------------------------------------------------------------------------------------------------28
13 Part List ----------------------------------------------------------------------------------------------------------29
Owner’s Manual
2

1.SAFETY INSTRUCTIONS
Our generators are designed to give safe and dependable service if
operated according to instructions. Read and understand the owner's
manual before operating the generator. Failure to do so could result in
personal injury or equipment damage.
Exhaust gas contains poisonous contents (eg. carbon monoxide).
Never run the generator in an enclosed area.
Be sure to provide adequate ventilation.
The muffler becomes very hot during operation and remains hot for a
while after stopping the engine. Be careful not to touch the muffler while
it is hot. Let the engine cool before storing the generator indoors.
The engine exhaust system will be heated during operation and remain
hot immediately after stopping the engine.
To prevent scalding, pay attention to the warning marks attached to the
generator.
Never connect a cable other than the special cable for parallel operation
to the parallel operation socket.
Electric shocks can result if this instruction is not followed.
3500W Digital Generator
3

Gasoline is extremely flammable and explosive under certain conditions.
Refuel in a well ventilated area with the engine stopped.
Keep away from lighted cigarette, fire and sparks when refueling the generator.
Always refuel in a well-ventilated location. Wipe up spilled gasoline at once.
Connections for standby power to a building's electrical system must be made
by a qualified electrician and must comply with all applicable laws and electrical
codes. Improper connections can allow electrical current from the generator
to back feed into the utility lines.
Such back feed may electrocute utility company works or other personel who
contact the lines during a power outage, and when utility power is restored, the
generator may explode, burn, or cause fire in the building's electrical system.
Always make a pre-operation inspection before you start the engine. You may prevent an
accident or equipment damage.
Place the generator at least 3ft away from buildings or other equipment during operation.
Operate the generator on a level surface. If the generator is tilted, fuel spillage may result.
Know how to stop the generator quickly and understand operation of all the controls.
Never permit anyone to operate the generator without reading and understanding the
instructions in this manual.
Keep children and pets away from the generator when it is in operation.
Keep away from rotating parts while the generator is running.
The generator is a potential source of electrical shocks when misused.
Do not operate the generator in the rain or snow and do not let it get wet.
Owner’s Manual
4
Do not operate with wet hands.

2.SAFETY LABEL LOCATIONS
2.1 Outside view
Fig.1 Outside view
Fuel level indicator
Air exhaust hole
Top cover
Air intake hole
Rear cover
Access door
Starter grip
Control panel
Fuel filler cap
Air intake hole
Front cover
LCD screen Operation button
Side cover
3500W Digital Generator
5

2.2 Control pannel
Fig.2 Control panel
ON: Engine speed is kept at economical state automatically to minimize the fuel
consumption while in operation.
This position is recommended when the output power is less than 1 kW.
2.3 ECON switch
When high electrical load appliances are connected simultaneously, turn the ECON switch
to the OFF position to reduce voltage changes.
ECON switch system does not operate efficiently if the electrical appliance requires the
higher needed electric power.
OFF: ECON switch does not operate . Engine speed is kept over rated speed.
Grounding terminalChoke knobStart button
Oil Alert Lamp
Fuel valve lever
Engine switch
Econ switch
Operation indicator (green) Overload indicator (yellow)
Short circuit indicator (red)
DC terminal
AC receptacle
Owner’s Manual
6

2.4 LCD screen and operation button
Fig.3 LCD screen and operation button
LCD screen displays the AC/DC output state and the wattages of electrical load.
The AC/DC output is kept in OFF (no output) when the engine is started.
AC operation button switches the AC output between ON and OFF.
DC operation button switches the DC output between ON and OFF.
If the generator is overloaded, the overload indicator (yellow) will go ON.
If there is a short in the connected appliance, the AC/DC output will be shut off automatically
while the short circuit indicator (red) will be ON.
ALM operation button is used to reset the generator when short circuit occurs.
Press the DISP operation button once, the LCD screen backlighting will remain ON for about 5
LCD screen back light
DC switch
AC switch
LCD screen
DISPALMDCAC
Alarm clear
3500W Digital Generator
7
seconds. This helps to operate in the dark.
Be sure to check the generator on a level surface with the engine stopped.

3.PRE-OPERATION CHECK
3.1 Check the engine oil level.
Using nondetergent oil or 2-stroke engine oil could shorten the engine's service life.
Use high-detergent, premium quality 4-stroke engine oil, certified to meet or exceed
U.S. automobile manufacturer's requirements for APL Service Classification SG, SF.
Select the appropriate viscosity for the average temperature in your area.
SAE Viscosity Grades:
Open the access door. Remove the oil filler cap, and wipe the dipstick with a
clean rag. Check the oil level by inserting the dipstick in the filler hole without
screwing it in. If the oil level is below the end of the dipstick, refill with recommended
oil up to the top of the oil filler neck.
Fig.4
Upper limit
Lower limit
single
viscosity
multi-
viscosity
10w
20w
20
30
40
20w-40.20w-50
15w-40.15w-50
10w-40
100w-30
-20
020 40 60 80 100F
-10 0 10 20 30 40C
Oil dipstick
Owner’s Manual
8
Indice
Altri manuali ALLPOWER Invertitore

ALLPOWER
ALLPOWER All-Power APG3004A Manuale utente

ALLPOWER
ALLPOWER APG3203 Manuale utente

ALLPOWER
ALLPOWER APGG6000C Manuale utente

ALLPOWER
ALLPOWER APG3005 Manuale utente

ALLPOWER
ALLPOWER APG3202 Manuale utente

ALLPOWER
ALLPOWER APGG12000GL Manuale utente

ALLPOWER
ALLPOWER APGG12000 Manuale utente

ALLPOWER
ALLPOWER APG3560 Manuale utente

ALLPOWER
ALLPOWER APG3001 Manuale utente

ALLPOWER
ALLPOWER AP G3102 Manuale utente