Alpha Technologies Blue Gate A Brave Manuale utente

G S M G A T E
Blue Gate A Brave
Installation guide V 2.5

1
Basic features:
Blue Gate A Brave is GSM Gate based on Telit GL865
equipped by a lot of adjustable features increased comfort of
service. It has been designed for GSM network
850/900/1800/1900Mhz.
Polarity reversal of telephone line allows exact detection of
start and end of call.
CLIP support all ordinary protocol.
Call billing allows control exact call duration due tax pulses
12/16 kHz (1. pulse when outgoing call is picked up).
Beeps in minute period into the call allows easy
identification of GSM call.
Monitoring systém allows sending SMS to preprogrammed
number when voltage of Back up batteries drops, unit is
logged to GSM network, no picks up number of ringing
called person/connected device doesnt react for ringing)
etc.
Direct Call (Baby Call) - Automatic dialing the number
stored on the SIM
Options:
Option USB port with PC software allows you easy
configuration as same as sending and receiving SMS
messages ( via SMS mail sw)* or data transmission.
You can add a backup battery for up to 10 h of operation at
power failure.
Sending of status SMS : 1-30 days (adjustable);
2 inputs with SMS sending feature when inputs status is
changed (up settings);
Thanks of many BlueGate features you can satisfy very wide
group of customers. By setting of permitted numbers to
memory of BlueGate you can restrict unrequested calls (to
public numbers).As same as you can set BlueGate to provides
incoming calls only.

2
INSTALLATION
Power
supply
telephone
line
antenna
SIM
telephone line
USB option
telephone line
MiniUSB

3
Insert the SIM card up the picture and by press fix it in
operation position. Before inserting the SIM card we
recommend checking at various mobile phone state of
the SIM card (logging with or without PIN, PIN, etc.) and
set logging without PIN. When you want logging with PIN
you have to preprogrammed this PIN and set logging with
PIN (via table of programming). Without this setting the
Gate wont work.
DO NOT FORGET ANTENNA CONNECTION! The available
place for installation select up following point of view:
1. distance from PBX – possibility of GSM interferences to
other PBX lines as same as lenght of line from Gate to
PBX (max. 200m)
2. main 230 V for power supply of Gate
3. Quality of GSM signal at the installation place of GSM
Gate
Quality of GSM signal
The sound quality depends on BTS setting where you are
connected by the Gate. To find best place for antenna
mounting you can use either mobile phone or yellow LED
flashing on front of unit (via. Table at the end of manual). The
suitable signal power is 3 scales of mobile graduation.
To check and find best position from GSM signal point of view
you can use also GG SET ( configuration sw). More in manual
for GG SET.

4
Connection of antenna
When you connect magnetic antenna keep on mounting at
bigger iron subject. This subject makes „against-weight“ at its
depends the power of radiated signal
When you inserted SIM card as same as all cables are
connected (do not forget that Blue gate is connected on
external line not on extension) connect device to main
230V. Blue LED “feeding” lights up (via LED table) and starts
flashing yellow GSM LED in rhytm of busy tone. After cca 30
seconds the yellow LED start flashing up GSM signal strength
( via LED table).When pick up connected analogue phone or
call to BlueGate from PBX the LED of analogue line lights up
(green LED). In the phone is hearing dial tone of BlueGate. It
is ready to use.
The most often problems during Blue Gate
compact installation:
All LED is not lighting.Problem in power supply. Check
connection to main 230V as same as connection of
adapter to BlueGate.
The LED “power supply” lights. When you make connection
to Gate green LED is ON and in handset you hear busy
tone. Yellow LED flashing in period „GSM modul doesnt
communicate with CPU“. During work with USB could
be programmed fix communication rate for GSM modul.
Use USB to programm rate on „autobauding“.
The yellow LED flashing in period „PIN unreadable“. After
calling to BlueGate you get busy tone. The SIM card

5
requires PIN, which is not preprogrammed or is
preprogrammed wrongly.
The LED „communication to GSM„ is flash shortly one for
2 sec. After calling to BlueGate you are hearing busy
tone. BlueGate is not log into GSM network – bad signal.
The yellow LED „communication to GSM„ is flashing up
signal strength“. After calling to BlueGate is not light up
green LED is not light up and in analogue phone is quiet.
It interrupted conduction of analogue line or so much big
resistance in current loop (for example:( longer cabel
between PBX and BlueGate).
Tle yellow LED „communication to GSM„ is flashing up
signal strength“ as same as green LED lights up. Tle
PBX hold „pick up“ line of GSM Gate. By incoming call
you can remove this issue. In other cases check PBX
manual.
The BlueGate works but call is disturbed by interference.
Incorrect position of antenna against telephone line.
Change antenna position.
Note:.
Default you make by parametr 99 in programming mode (via
programming table at page 11).
Alle LEDs flashing as same as tone types are mentioned in
tables at the end of manual.

6
USB
You can purchase USB tool for PC configuration of the unit. It
is optional. This tool is connected via 6 wire cable to the units
in middle of phone line. (via picture on page 2). You can
control GSM modul directly via virtual COM port. The Gate you
can further use ordinary GSM modem for data transmission,
internet connection or for SMS messages.
When unit is working as GSM modem then is busy for voice
connection. When you pick up the line you will hear busy tone.
The unit is monitoring data transmission by modem. The data
transmission can not be permanent therefore the unit stays in
data mode 10 seconds after finishing of data transmission.
Then is going back to Voice mode (calling).
The same is when you are calling over unit. It is busy for
data transmission.
The optional sw supply to unit for sending and receiving
SMS messages is SMS mail. It is working under Outlook,
Outlook Expres, Opera etc. And you can work with SMS as
with normal e mails. ( see manual for SMS mail). It works in
batches and allows programm communication interval (1 to 99
minutes) to BlueGate for sending and receiving SMS. Due this
we avoid situation that unit is permanentlky blocked by data
mode for voice communication.
Further functionality of USB is monitoring BlueGate
operation. It is possible record even incoming calls includes
time and CLIP, signal strength, etc..

7
CONFIGURATION
The programming mode is set after acknowledgement dialing
to Blue Gate.In the analogue phone is waiting tone. After
password inserting is tone changing to programming tone.
Then you can programming each features of Blue Gate (via
table of programming)
Progress of programming:
Dial 2 digits number of programming feature.
Dial 1 to 4 digits number for feature value programming.
Wait for a tone of confirming request (3 short tones).
Confirm the feature by dialling acknowledgement (#)
Wait for confirming tone.
Follow programming tone again.
Finish programming by hang up a phone.
Example: programming of new permitted fix numbers (02)
to memory 09:
Dial acknowledgement (default is #). In phone you are hearing
waiting tone (). Dial password (default 0000).
Waiting tone is changing to programming tone ().
Dial 1902. Wait for tone of confirming request (3 short tones).
Confirm the feature by dialling acknowledgement (#). Wait for
confirming tone (one long tone). Finish programming mode by
hang up a phone.
Warning: After dialling of parametr value you have to wait
for 3 short tones and then dial acknowledgement # . Wait
for long tone confirm acceptation of this parametr .

8
Notes to each parametres:
11 - 19 When you programm some prefixes the BlueGate A
Bravellows outgoing calls starts by those prefixes only.
The others will get busy tone. When memories will be
empty the calling wont be restricted (default). Memory
of prefixes can content 1 digit only. If you insert 1 digit
only the BlueGate will check first position only.
Rewriting of memory – by storing of new fix-
numbers are old fix-numbers erased.
Erasing of memory - Memory you will erase by
storing of „nothing“. You
dial only number of memory which you want erase and
confim it.
22 very important feature is acknowledge character
setting. Default is #. When is # used for PBX features
you can change it on *.
32,35 The GSM phones requested command to connection on
inserted number. The BLUE GATE will send a
command immediately after acknowledge character
dialling (#).
27,37 These parameters can be entered (if necessary)
immediately after switching gates (Go into the
programming mode in the busy tone - see note. 3
below). Without their setting, in some cases, may not be
available SIM card (PIN, type of SIM card).
33 Direct Call - When the value is 01 (the shortest waiting
time to dialing) is activated "Direct Call" (Baby Call).
After picking up is no need to dial a phone number. Is
automatically dialed phone number stored on the SIM
card under the name DCALL. Store the number on the
SIM either by directly writing after inserting the SIM card

9
into any mobile phone or by software GGset (folder
"Phone Book")
Notes:
Changes are valid after hang up only (finishing of
programming mode). It is very important especially in
acknowledge character changes- till hang up you must
use previous acknowledgement.
After numbers dialing you must wait for confirming
request , insert acknowledge character and wait for
confirming tone. When you insert acknowledge
charater before wont be accepted.
Switch to programming mode is possible even in busy
tone.
Some parametres are possible to programm by PC only
Indice
Altri manuali Alpha Technologies Portale
Manuali Portale popolari di altre marche

LST
LST M500RFE-AS Manuale utente

Kinnex
Kinnex Media Gateway Manuale utente

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuale utente

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuale utente

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuale utente

Telsey
Telsey CPVA 500 - SIP Manuale utente