Amcor HD 2000HT Manuale utente

HD 2000HT 3000HT
DEHUMIDIFIER
www.amcorgroup.com
抽濕機
除湿器
GB Instruction Manual
TC 說明書
SC 用户手册
www.amcorgroup.com

2
THANK YOU
DO NOT USE YOUR DEHUMIDIFIER UNDER THE FOLLOWING CONDITIONS:
• For safety reasons, read this manual carefully before operating.
• Persons who are not familiar with this manual must not use this product.
• We strongly recommend keeping this manual in a safe place for future reference.
GENERAL SAFETY
Thank you for choosing this innovative Amcor dehumidifier. The instruction manual
describes the many benefits and advanced features that this unique product has to
offer. Before you use your new dehumidifier you should carefully read the instruc-
tions to get long lasting results from this excellent product. We suggest that you
keep the manual in a safe place for future reference.
For over 50 years, Amcor has specialised in complete indoor environment
control,manufacturing dehumidifiers, portable air conditioners, coolers, air puri-
fiers/ ionisers and aromatherapy products. These world class products incorporate
the latest technological developments and are designed to create a quality environ-
ment.

GB
3
GENERAL SAFETY
HOW IT WORKS
Your Amcor dehumidifier draws in air through the lower front panel onto a refriger-
ated cold grill. As the air in the room passes over the cold surface, moisture con-
denses and collects into a front loading removable high capacity 7-litre water tank.
The drier, slightly warmer air is then expelled through the front upper grill back into
the room.
The Amcor dehumidifier fights condensation, mould and dampness throughout the
house.
– And it is also great for drying the laundry!
Your Amcor dehumidifier may incorporate a fragrance emitter (selected models)
located on the back of the unit. When the fragrance is no longer noticeable, the
fragrance capsule should be replaced by a fresh one. To change capsules, rotate the
knob located on the back of the unit anticlockwise and insert a new capsule which
can be ordered from the Amcor help-line
SAVE ENERGY
Did you know it takes less heat to warm dry air than damp humid air!

GB
4
CONTROLS
CONNECTING TO THE MAINS SUPPLY
POSITIONING YOUR DEHUMIDIFIER
Your Amcor dehumidifier will begin to protect your home from the harmful effects
of excessive moisture as soon as it is turned on.
Excess moisture will travel throughout your home, in the same way that cooking
smells spread to every room in the house. For this reason, the dehumidifier should
be positioned in a central and clear location so that it can draw this moist air to-
wards it from all over the home. A warm hallway or landing is an excellent position
for your dehumidifier. If possible, leave interior doors partly open. Alternatively,
if you have a serious problem in one area you can begin by positioning the dehu-
midifier close to this area and later moving it to a more central point. Do not place
directly against a radiator or other heat source.
For the most efficient use, outside doors and windows should be kept closed when
the dehumidifier is operating.
When positioning your Amcor dehumidifier, ensure that it is placed on a level sur-
face clear of any obstacle that may limit the air movement.
Your Amcor dehumidifier is fitted with 2 front castors and 2 large integrated back
wheels for easy movement including stairs.
If you move the unit, it should first be switched off and the water tank emptied.
A cable tidy is conveniently located at the back of the unit for storage of the cable
when the unit is not being used.
The first time that you use the unit please ensure that it has been standing for 2
hours in an upright position before it is switched on.
Plug the unit into a properly earthed mains socket.
Your Amcor dehumidifier is now ready for use.
Please note, If the supply cord is damaged, it must be replaced by an approved ser-
vice representative or a similar qualified person in order to avoid a hazard.
IMPORTANT: THIS UNIT SHOULD NOT BE USED AT TEMPERATURES BELOW
5°C

GB
5
CONTROLS
CONNECTING TO THE MAINS SUPPLY
POSITIONING YOUR DEHUMIDIFIER
Control Panel Indicator:
1. POWER: indicating if the compressor is running- it will go off when in defrost
mode and when the unit has achieved the requested relative humidity level.
2. TIMER: timer indication – to show that either the start or the stop or both tim-
ers are set.
3. High speed fan
4. Low speed fan
5. Humidity requested: display shows the selected relative humidity level
6. CONT: continuous, display shows that the unit will run without considering the
air’s relative humidity
7. WATER FULL: water full indication, advises when it is time to empty the water
tank
8. HEAT indicator: visual display that the heater is on
9. LED: relative humidity indicator
10. Clock
11. OFF: timer “off” indicator
12. ON: timer “on” indicator
Control Buttons
ON/OFF _ SPEED _ HEAT _ SET _TIMER _ UP _ DOWN
When buttons on the control panel are pressed, a beeping sound will be heard .

GB
6
ON/OFF button
Switches the unit on or off, while the compressor is running, the POWER light [1] is
on.
Fan SPEED Control
The Amcor dehumidifier features a two-speed fan control. Press the button marked
“SPEED” to illuminate the high fan speed indicator [3] for fast operation. For qui-
eter operation press the” SPEED” button to illuminate the low indicator [4].
Relative Humidity Setting
By depressing button “UP or DOWN” repeatedly you can choose from a range of
relative humidity settings:
CONT [6] _ 50% [5] _ 60% [5] _ 70% [5] _ 80% [5]
Generally we feel most comfortable when the setting is 50%-60%. Select your pre-
ferred humidity level and the unit will run until the moisture in the room reaches
the desired level. From then on it will cycle on and off to maintain the level chosen.
If “CONT.” is selected [6], the dehumidifier will run continuously irrespective of
how dry the air becomes.
The digital display indicates the actual relative humidity level in the air. In most
cases you will see a reduction in condensation within a few days. In severe cases,
however, it may take several weeks to remove sufficient moisture to obtain an ac-
ceptable humidity level.
HEAT button
The 800W fan heater, activated by depressing the HEAT button, only runs with high
fan speed. The HEAT indicator [8] will come on when the heater is operating.
To activate the heater without dehumidification select 80% RH as explained above
and then press the heat button. The compressor will stop (power light 1 will go off)
and the heater only will run with high speed fan.
The heater should not be used in room temperatures above 21˚C. Above 25 ˚C the
heater will automatically cut off.
The unit will discharge warm dry air from the top grill making it effective in drying
damp items e.g. clothes in the area.
To avoid possible heat damage to fabric leave at least 1 m gap around the unit.
Garments must not be dried on top of this unit; this will restrict the air flow, cause
damage to the unit/ fabric and present a risk of fire / electrical shock.

GB
7
Programming the 24 hour clock.
A 4 digit LED display will constantly indicate the real time.
The real time setting procedure:
Press the “SET” button for 2 seconds. The 2 digits on the left of the display [10] will
blink indicating it is now possible to change the hours setting on the clock.
Repeatedly press the “UP” or “DOWN” button until the correct hour is shown.
Press the SET” button for the second time until the 2 right digits in the 4 digit
display [10] blink indicating it is now possible to change the minutes setting on the
clock.
Repeatedly press the “UP” or “DOWN” button until the correct minute(s) is
shown.
Press the “SET” button for the third time.
The current time is set, the 4 digit display indicates the time constantly until the
Time button [11] is pressed to program the timer.
Programming the Timer – when the machine is OFF
Please familiarise yourself with this sequence before setting the timer. Long delays
in the sequence of setting will cause the timer to revert back to the 24 hour clock
display. This will then involve starting the sequence again from the beginning.
Press the “TIMER” button when the unit is off.
The 2 digits to the left of the 4 digit display – the hours - will blink indicating it is
possible to change the hours setting on the timer. Additionally the word ON will be
shown alongside the digits.
Repeatedly press the “UP” or “DOWN” button until the desired hour is shown on
the timer.
Press the “TIMER” button again.
The 2 digits to the right of the 4 digit display – the minutes - will blink indicating it
is possible to change the minutes setting on the timer. Additionally the word ON
will be shown alongside the digits.
Repeatedly press the “UP” or “DOWN” button until the desired minutes are shown
on the timer.
AT THIS POINT YOU HAVE TWO OPTIONS EITHER
1. Press “SET” and the unit will switch on at the desired time and remain ON.
It will switch on at the setting that was last used. The Timer Light will illuminate.

GB
8
OR ALTERNATIVELY TO SET THE “OFF” TIME
2. Press the “TIMER” button again and the 2 digits to the left of the 4 digit display
will blink indicating it is possible to change the hours setting on the timer. Ad-
ditionally the word OFF will be shown alongside the digits. Follow the proce-
dure for setting the “ON” timer but this time set the “OFF” timer. When this is
complete press “SET”. The Timer Light will illuminate. The unit will now switch
both ON and OFF at the times set.
In both cases the clock will revert, within 10 seconds to show the real time and a
small clock graphic will appear in the window to show the timer is set.
Pressing either the “TIMER” or “SET” button at any time after the timer has been
set will cancel the settings.
Programming the Timer – when the machine is ON
The timer can be set in exactly the same way as described above. The only differ-
ence is that the first timer to be set will be the “OFF” timer. Then again.
YOU HAVE TWO OPTIONS EITHER
Press “SET” and the unit will switch off at the desired time and remain OFF. The
Timer Light will illuminate to show the timer is set.
OR ALTERNATIVELY
Press the “Timer” button again and the 2 digits to the left of the 4 digit display will
blink indicating it is possible to change the hours setting on the timer. Additionally
the word ON will be shown alongside the digits. Follow the procedure for setting
the “OFF” timer but this time set the “ON” timer. When this is complete press
“SET”. The Timer Light will illuminate. The unit will now switch both OFF and ON
at the times set.
In both cases the clock will revert, within 10 seconds to show the real time and a
small clock graphic will appear in the window to show the timer is set.
Pressing either the “TIMER” or “SET” button, or switching the unit off at any time
after the timer has been set will cancel the settings.
Defrost Control
Your Amcor dehumidifier is equipped with an intelligent defrost system which has
an automatic de-icing mode to defrost the cold coil on which ice forms during low
temperatures or low humidity operation. The defrost system will switch the com-
pressor off and on periodically according to the condition of the cold coil and the
room air temperature. When in defrost mode the fan will operate continuously and
the power light [1] will blink.
Please remember that this dehumidifier is not to be used in temperatures below
5˚C.

GB
9
Continuous Drainage Option
This unit can alternatively be used with a continuous
drainage hose as follows:
• Remove the water container from the unit.
• Pull the funnel selector to the continuous drainage
position A as shown in fig 1. it should be pulled
forward and clicked into position. This avoids any
leakage.
• Pull out the water stopper at the back of the water
unit (fig 2) and insert a 6mm diameter (1.5mm
thick) hose over the spout.
• Place the other end of the hose in a drain, ensur-
ing that it is not twisted, folded, or otherwise likely
to obstruct the water flow.
• The hose must be positioned so that there is a
gradual downward slope from the connection
point to the drain.
• Ensure that the outlet of the drainage pipe is not
under the water level in the drain.
• Replace the water container.
Note: In very cold weather conditions precautions should be taken to prevent the
drainage pipe from freezing.
To return to water tank use, push the funnel selector into position B (fig1) and rein-
sert the water stopper (fig 2).
Water Full Indicator [7]
When the water tank is full, the “water full” indicator light [7] will illuminate and the
unit will automatically shut off and beep repeatedly to indicate that the water tank is
full. See instructions for emptying the water tank.
The water full indicator light will also illuminate and the unit will beep if the water
tank has not been properly inserted or if it has been removed. Once the tank is emp-
tied and replaced correctly, the unit will re-start.
Emptying the Water Container
When the water container is full the water full indica-
tor light will illuminate and the unit will automatically
shut off. Wait a few minutes to allow the water to fin-
ish draining into the water container. To remove the
water container, pull the lower front panel forward.
Pull out and lift the water tank by the handle and
carry it away for emptying. Gently replace the con-
tainer and close the lower front panel. When the tank
is properly inserted, both the hole and the float
mechanism in the container will be located directly beneath the drainage spout and
the water full indicator light will go out.

GB
10
Washing and changing the Filters
The Amcor dehumidifier features two filters: a
replaceable activated carbon filter to remove odours
and a washable high efficiency dust filter to purify the
air. It is recommended to clean the washable air filter
at regular intervals depending upon how frequently
the unit is used, at least every 3 months.
To do this, first remove the water tank. Pull down and
remove the filter-housing unit that incorporates both
filters. Push the filter locks on either side of the filter-
housing unit and remove the filter fame. Take the
carbon filter out of the housing unit. The dust filter
can then be washed under running water. It must
be dried before inserting it back into the unit. The
carbon filter cannot be washed but can be
vacuum cleaned. It is recommended to replace the carbon filter every 12 months,
depending upon how frequently the unit is used. Replace the filter frame with the
word front outside.
For replacement filters please contact the dealer or Amcor hotline number.
TECHNICAL DATA
Model No. HD2000HT HD3000HT
Mains 220-240V / 50Hz
Water extraction -at 32˚C 90%RH
-at 30˚C 70%RH
L/24hr 14 22
9 15
Water tank capacity L 7
Refrigerating agent R134A
Temperature range ˚C 5 - 35
Power consumption-Dehum W 230 370
Power consumption -Heater W 800
Max. airflow m3160 180
Dimensions of unit (W x H x D) mm 345 x 722 x 325
Wheel diameter mm 120
Weight kg 18 21.5
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Amcor Deumidificatore

Amcor
Amcor AD 400E Manuale utente

Amcor
Amcor AD12 Manuale utente

Amcor
Amcor SD12 Manuale utente

Amcor
Amcor DES 80 Manuale utente

Amcor
Amcor PLDA 25EH Manuale utente

Amcor
Amcor D-850 Manuale utente

Amcor
Amcor D850E Manuale utente

Amcor
Amcor HD220 Manuale utente

Amcor
Amcor Ad 140 Manuale utente

Amcor
Amcor DSR-12/20 Manuale utente

Amcor
Amcor D-1000 Manuale utente

Amcor
Amcor System QT 120 Manuale utente

Amcor
Amcor MD280 Manuale utente

Amcor
Amcor MD250 Manuale utente

Amcor
Amcor HD220 Manuale utente

Amcor
Amcor D850E Manuale utente

Amcor
Amcor MD250 Manuale utente

Amcor
Amcor AM-DD8L Manuale utente

Amcor
Amcor DC 14 Manuale utente

Amcor
Amcor DC-900 Manuale utente