American Auto-Matrix AspectFT-Nexus Manuale

Hardware Installation Guide
Nexus™ & Facility™

AspectFT-Nexus™ and AspectFT-Facility™Hardware Installation Guide
Part Number 1E-01-00-0064
© 2014 American Auto-Matrix®
This document is protected by copyright and is the property of American Auto-Matrix. It may not be used or
copied in whole or in part for any purpose other than that for which it is supplied without authorization. This
document does not constitute any warranty, expressed or implied.
Every effort has been made to ensure that all information was correct at the time of publication. American
Auto-Matrix reserves the right to alter specifications, performance, capabilities and presentation of this
product at any time.
American Auto-Matrix, Auto-Matrix, Smart Building Solutions, AspectFT, and vSTAT are registered trade-
marks of American Auto-Matrix. AspectFT-Studio, AspectFT-Matrix, AspectFT-Facility, AspectFT-Nexus,
and AspectFT-Enterprise are trademarks of American Auto-Matrix. These trademarks or registered trade-
marks are not to be used for publication without the written consent of American Auto-Matrix.
All other brand names or product names are trademarks or registered trademarks of their respective com-
panies or organizations.
WORLD HEADQUARTERS
American Auto-Matrix
One Technology Lane
Export, Pennsylvania 15632-8903 USA
Tel (1) 877-AAM-HVAC
Fax (1) 724-327-6124
Email aam@aamatrix.com
www.aamatrix.com

AspectFT-Nexus & AspectFT-Facility Installation Guide (1/02/2014) 1-1
1.1 INTRODUCTION
Unpack your AspectFT-Nexus and AspectFT-Facility hardware and inspect the contents of the package for
damaged or missing items. Included in this package, you should find the following items:
.AspectFT-Nexus and AspectFT-Facility Appliance
.AspectFT-Nexus and AspectFT-Facility QuickStart Guide
1.1.1 TOOLS REQUIRED
The following tools and supply may be required for installation:
.Slotted 2.5 mm precision screwdriver- for power and field-bus connectors
.1/8” hex key- to fasten the cover
.Wire-strippers - for terminating EIA-485 connections and power connections
1.1.2 SAFETY PRECAUTIONS
NOTE
All equipment must be installed in accordance with
NEC and local codes. For more information on
local codes, please check state/local regulations in
your area.
CAUTION
Ensure that this product is installed in an operating
environment where the ambient temperature does
not exceed the maximum rated ambient
temperature of the unit.
SECTION 1
HARDWARE INSTALLATION
The following provides mounting, wiring and installation of AspectFT-Nexus and AspectFT-Facility. Please
read through this document carefully before beginning the installation procedure.

1-2 AspectFT-Nexus & AspectFT-Facility Installation Guide (1/02/2014)
1.1.3 STATIC DISCHARGE PRECAUTIONS
Static discharge can produce voltages high enough to damage electronic components. The
microprocessor and associated circuitry within this product are sensitive to static discharge. Follow these
precautions while working with the product in both installed and un-installed modes.
.Work in static free environments
.Discharge any static electricity you may have accumulated by touching a known, securely grounded
object.
1.1.4 MISCELLANEOUS PRECAUTIONS
WARNING
Ensure ALL Ethernet Network Interface
Connections (i.e. RJ-45) are never attached to
Public Telephone Server Provider Sources.
WARNING
Follow the precautions provided specific to
static discharge.
NOTE
Do not apply this product to aerospace systems,
mainline communication systems, nuclear power
control systems or medical equipment involved in
life support that require high reliability and safety,
as it is not intended for such use or application.

AspectFT-Nexus & AspectFT-Facility Installation Guide (1/02/2014) 1-3
NOTE
This equipment has been tested and found to
comply with the limits for a Class A digital device,
persuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when the equipment is
operated in a commercial environment. This
equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instruction manual, may cause
harmful interference to radion communications.
Operation of this equipment in a residential area is
likely to cause harmful interference in which case
the user will be required to correct the interference
at his own expense.
NOTE
Batteries on the AspectFT-Nexus and AspectFT-
Facility are not designed to be user replacable.
Return the Nexus to American Auto-Matrix when in
need of a replacement.

1-4 AspectFT-Nexus & AspectFT-Facility Installation Guide (1/02/2014)
1.2 PRODUCT MOUNTING
This product ships with an approved enclosure consistent with most electrical standards and regulations.
The product is intended for indoor applications only and should be installed in a location that is dry, and
free from excessive dust, vibration, and electrical interference. Mount the product in a location that allows
clearance for ease of wiring and service. Use the two keyhole-style screw holes located on the back of the
enclosure for assistance with mounting.
Figure 1-1 AspectFT-Nexus and AspectFT-Facility
1.2.1 ENCLOSURE COVER
The enclosure cover of the Nexus controller is designed to be removed for servicing the device. The cover
is removed by unscrewing the 4 hex head screws in the cover then sliding the cover vertically before
pulling it away from the base. Care should be taken when removing the cover on a mounted unit to prevent
it from being dropped and damaging the cover or harming the user.

AspectFT-Nexus & AspectFT-Facility Installation Guide (1/02/2014) 1-5
Figure 1-2 AspectFT-Nexus and AspectFT-Facility Cover
CAUTION

1-6 AspectFT-Nexus & AspectFT-Facility Installation Guide (1/02/2014)
1.3 HARDWARE LAYOUT
Below is an illustration of the hardware layout of the AspectFT-Nexus and AspectFT-Facility. The device
includes connection ports for main power, EIA-485 connectivity, and Ethernet connectivity.
Figure 1-3 Hardware Layout
1.3.1 UNUSED PORTS
The motherboard of AspectFT-Nexus and AspectFT-Facility controller contains 3 RS-232 serial ports,
3.5mm audio ports, and a DC support port. These ports contain no field functionality, but are reserved for
future functionality.
1.3.2 POWER REQUIREMENTS
This product requires a transformer capable of providing 24VAC power to the AspectFT-Nexus and
AspectFT-Facility. Use a UL listed Class 2, 24VAC transformer.
To connect power to the product, use the supplied two-position terminal plug. The output leads from the
transformer should be connected to the terminal plug. The terminal plug should then be connected into the
socket on the board. American Auto-Matrix recommends using 18AWG cable for power wiring.
WARNING
Do not share the power source for the
AspectFT-Nexus and AspectFT-Facility with
other devices. Damage to the product as a
result of improper power and wiring will void
product warranty.

AspectFT-Nexus & AspectFT-Facility Installation Guide (1/02/2014) 1-7
Figure 1-4 Power Connection
1.3.3 LED INDICATION
The PCB of the product includes diagnostic LEDs, providing user feedback when power has been
connected to the device. When power is connected, the LEDs should be illuminated. The power
diagnostic LEDs are located along the edge of the board.

1-8 AspectFT-Nexus & AspectFT-Facility Installation Guide (1/02/2014)
1.4 COMMUNICATION CONNECTIONS
Communication connections made to device should be made with care. To avoid any possible conflict with
existing network communications, it is recommended that communication port and network configuration
of the device be performed prior to connecting the product to any associated field bus network.
1.4.1 ETHERNET NETWORK
Ethernet is a high-speed LAN widely used in commercial buildings. The main Ethernet network interface is
located on the motherboard of the product directly next to the serial RS-232 ports. A second Ethernet
connection, located next to the audio ports, is not active for use at this time.
The on-board Ethernet network interface supports 10Base-T (10Mbps), 100Base-T (100Mbps) and
1000Base-T(gigabit) Ethernet connections. The product will automatically switch to 100Base-T operations
if other devices and cabling connected to the same subnetwork support this.
1.4.1.1 CABLE TYPE AND LENGTH
Use an approved Category 5 (CAT5) Ethernet patch cable with RJ-45 plugs to connect the product to an
Ethernet switch or hub. Use professionally manufactured cables to assure transmission rates and
reliability between devices. Maximum length for Category 5 is typically limited to about 320 feet (100
meters).
Figure 1-5 Standard Ethernet Connection Pinout
Pin 7
Reserved
Pin 8
Reserved
Pin 6
Receive -
Pin 5
Reserved
Pin 1
Transmit +
Pin 2
Transmit -
Pin 3
Receive +
Pin 4
Reserved
Questo manuale è adatto per i seguenti modelli
1
Indice