Analytic Systems IPSi365M Manuale utente

INSTALLATION &
OPERATION MANUAL
IPSi365M
INTELLIGENT
PURE-SINE
INVERTER
101-8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)
www.analyticsystems.com
An ISO9001 Registered Company Battery Chargers •Inverters •Power Supplies •Voltage Converters

2
MEDICAL EQUIPMENT NOTICE
Analytic Systems does not recommend the use of their products in life support
applications where failure or malfunction of this product can be reasonably expected to
cause failure of the life support device or to signicantly affect its safety or effectiveness.
Analytic Systems does not recommend the use of any of its products in direct patient
care. Examples of devices considered to be life support devices are neonatal oxygen
analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes),
auto-transfusion devices, blood pumps, debrillators, arrhythmia detectors and alarms,
pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator
incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion
pumps as well as any other devices designated as “critical” by the U.S. FDA
DANGER: Never alter the AC power cord or plug provided. If it will not t the output, use
an approved adapter or have the proper AC power cord installed by a qualied electrician.
Improper connection can result in the risk of electric shock.
INVERTER
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS — This manual contains important safety instructions for
operating the Inverter.
INVERTER PRECAUTIONS
1. Do not expose the Inverter to rain or snow unless it is a sealed model.
2. Do not use any attachments with the Inverter unless recommended or sold by the manu-
facturer, this may result in a risk of re, electric shock, or injury to persons.
3. Do not disassemble the Inverter; if service or repair is required, return it to the manu-
facturer or an authorized service center. Incorrect reassembly may result in a risk of re,
electric shock, or injury to persons. Voltages in excess of 350 volts are present inside the
charger any time it is plugged into an AC outlet, even if switched off.
4. To reduce risk of electric shock, unplug the Inverter from the AC power before attempting
any maintenance or cleaning. Turning off controls will not reduce this risk.
5. Do not place Inverter directly above a battery; gases generated by battery will corrode
and damage Inverter.
6. Do not allow battery acid to drip on the Inverter.
GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS
The plug must be plugged into an outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
HEAVY DEVICE - The IPSi1000, 2000 and 3000 Inverters weigh more than 30lbs (13.6kg).
Please use appropriate safety measures when lifting or moving these units.

3
TABLE OF CONTENTS
• Front Cover, Product Photo and Title
• Product Warnings and Advisories
• Table of Contents
• Introduction / Box Contents
• Main Parts
• Operation
• Controls and Indicators
• Installation
• DC Connections / AC Connections
• Ofine UPS Option
• InverterWizard (Optional)
• Troubleshooting
• Specications
• Warranty
Revised - July 27, 2020
Copyright Analytic Systems Ware (1993) Ltd.

54
Introduction
The IPSi365M series of Intelligent Pure Sinewave Inverters are designed specically for
powering computers and other sensitive AC loads in off-grid environments. They produce
pure sinewave AC power, identical to a conventional AC outlet. Built for service in rugged
environments this unit features upgrades including expanded operating temperature, MIL-spec
connectors and enhanced shock and vibration protection.
Internally, the IPSi365M is controlled by a sophisticated Digital Signal Processor (DSP) for
optimal control and the most efcient operation possible. The heavy-duty Toroidal Power
Transformer steps the low voltage AC produced by the Power MOSFET Transistors to 110 or
220 VAC at 50 or 60 Hz. Additional ltering on the AC output reduces or eliminates EMI noise
that can interfere with sensitive communications equipment.
Built for the safest operation possible, this unit features low voltage warning with shutdown
circuitry to protect the DC power source. While the inverter is safeguarded by high voltage
and over temperature protection both with shutdown circuitry. All the alarm conditions can
be monitored on the bright LED indicator display which can also be mirrored on the optional
remote control panel.
Using the free-to-download InverterWizard software from Analytic Systems, you can change
the output frequency and adjust the voltage shutdown thresholds to ne-tune the inverter to
your needs as well as and view and record operating data from any PC with a standard USB
interface.
The box you have received should contain the following:
• 1 IPSi365M Intelligent Pure Sine Inverter
• 1 compatible USB cable
• 1 Warranty Card
• This User Guide (A PDF copy can be downloaded from www.analyticsystems.com)
Box Contents
If anything is missing or damaged please contact your dealer or Analytic Systems for a replacement.

54
1. USB Communications Port
2. AC Output Connection: Amphenol
circular MIL-spec GTS02R10SL-3P
connector
3. Remote Control Connection
4. Power Switch
5. DC Input Connection: Amphenol circu-
lar MIL-spec GTS02R-20-23P connector
Main Parts
1
5
2
Front Panel
3
4
1. Unit label location
2. Indicator LEDs
Top Panel
1
2

76
Operation
This unit is designed for simple and intuitive operation. Before operating, the inverter must be
properly installed and connected. See Installation and AC/DC Connections for more information.
TO OPERATE THE INVERTER:
1. Move the Power Switch to ON to energize the circuitry.
2. The Invert LED and either the 50 Hz or 60 Hz LED will glow green indicating proper
operation and the presence of AC power at the outputs.
3. The inverter will automatically begin supplying the connected load with voltage and
current printed on its label.
TO END OPERATION:
1. Move the Power Switch to OFF to end operation.
2. Wait for all the LEDs to turn off.
3. The inverter can now be safely disconnected from the load and power source. It can then be
serviced or put into storage.
There are eight indicator LEDs on the inverter’s top panel which display it’s operating condition.
The table below details their meanings:
LEDs Meaning
LOW
VOLTAGE
• Blinks red when the input voltage nears the minimum limit for proper operation.
• Glows red when the input voltage is too low for proper operation. The Bypass
LED will also glow red and the Invert LED will turn off.
HIGH
VOLTAGE
• Blinks red when the input voltage nears the maximum limit for proper operation.
• Glows red when the input voltage is too high for proper operation. The Bypass
LED will also glow red and the Invert LED will turn off.
OVER TEMP • Blinks red when the unit’s internal temperature nears the safe limit. The
inverter will automatically derate its maximum power rating to try to
maintain a safe operating temperature.
• Glows red when the inverter is too hot to operate. The Bypass LED will
also glow red and the Invert LED will turn off.
OVER LOAD • Blinks red when the current being drawn reaches the unit’s continuous rating.
• Glows red when the current being drawn reaches the unit’s peak rating.
50 HZ • Glows green if the inverter’s output frequency is set to 50.00 Hz. This
setting can be changed using InverterWizard,
60 HZ • Glows green if the inverter’s output frequency is set to 60.00 Hz. This set-
ting can be changed using InverterWizard.
BYPASS • Glows green if the inverter is in Bypass mode and functioning as an Off-line
Uninterruptible Power Supply. For more information, see Off-line UPS.
• Glows red when the inverter is experiencing a malfunction.
INVERT • Glows green when the inverter operating normally.

76
MOUNTING
Mount the unit in a DRY and WELL
VENTILATED area. Allow at least one inch
(2.54 cm) of clearance all around the unit for
adequate cooling.
CAUTION: DO NOT MOUNT THE UNIT
ANYWHERE EXPLOSIVE GASES CAN
ACCUMULATE.
A slight arc may occur when the power leads
are connected, and in the unlikely event of a
failure, sparks may be generated inside the
unit.
Installation
IMPORTANT: BEFORE CONNECTING OR DISCONNECTING ANYTHING TO THE
INVERTER, THE POWER SWITCH MUST BE TURNED OFF.
GROUNDING
The unit case is connected to AC Ground and AC Neutral in order to meet regulatory
requirements and reduce the possibility of it generating any radio frequency interference.
The unit case must be bonded appropriately to the grounding system of the vehicle or marine
vessel. On a vehicle, bond the case to the vehicle’s frame. On a marine vessel, bond the case
to the vessel’s hull. A grounding stud is provided on the front panel for this purpose.
To ensure proper grounding, check the connection with an ohmmeter. The case is isolated from
the DC input, so the DC power can be connected to a different ground from the AC output.
DISCONNECTING
If you need to disconnect the Inverter for service or storage:
1. Move the power switch to OFF and disconnect the DC power source.
2. With power disconnected, move the power switch to ON.
3. Leave the switch in this position for one minute to discharge the storage capacitors.
4. Return the power switch to the OFF position. Disconnect the load(s).
5. The inverter is ready for service or storage.

98
CAUTION: DO NOT APPLY AC VOLTAGE TO THE AC OUTPUT CONNECTION!
This will damage the inverter and will not be covered under warranty.
DC Connections
AC Connections
DC INPUT CONNECTION
This unit is equipped with an Amphenol circular MIL-spec GTS02R-20-23P connector to serve
as a DC Input Connection. Connect the DC power source here using wiring suitable for the
input amps. The maximum input amps can be found on the unit’s top panel label and also in
the Specications section.
The polarity of this connection can be found on the label on the unit’s front panel and also in
the table below.
AC OUTPUT CONNECTION
This unit is equipped with an Amphenol circular MIL-spec GTS02R10SL-3P connector to serve
as an AC Output Connection.
Connect the AC load here using wiring suitable for the expected output. The maximum output
current can be found on the unit’s top panel label and also in the Specications section.
Pin Polarity
Pin A AC Hot/Live
Pin B AC Neutral
Pin C AC Ground (Chassis)
Pin Polarity
Pin 1 DC Input Positive
Pin 2 DC Input Negative
CAUTION: DO NOT REVERSE CONNECT THE DC INPUT POWER!
This will damage the inverter and will not be covered under warranty.
IMPORTANT: BEFORE CONNECTING OR DISCONNECTING ANYTHING TO THE
INVERTER, THE POWER SWITCH MUST BE TURNED OFF.

98
Off-line UPS Option
The Off-line UPS (Uninterruptible Power Source) is an optional feature for this product line.
Inverters with the ofine UPS feature are constructed with an AC Input connection and
internal off-line AC Bypass circuit. In the event of external AC power failure so it can function
as a backup power source supplying the connected load.
TO SET UP THE OFF-LINE UPS
1. Connect the AC power source to the AC Input Connection.
2. Connect the DC power source to the DC Input Connection.
3. Connect the load to the AC Output Connection.
4. Turn the inverter ON, by pressing the Power Button or ipping the Power Switch.
Legend
AC Power Source
DC Power Source
Inverter Load
AC Current
DC Current
NORMAL OPERATION
• The AC power source operates normally.
• AC power is supplied to the inverter via the AC Input Connection.
• AC power continues to the load through an off-line bypass circuit via the AC Output
Connection. The inverter monitors the voltage going through the off-line. The BYPASS
LED will glow green indicating power on the off-line bypass.
• A battery is connected to the inverter’s DC Input Connection but the unit does not draw
power from this source as long as the inverter detects normal AC voltage.

1110
Legend
AC Power Source
DC Power Source
Inverter Load
AC Current
DC Current
AC POWER FAILURE
• The AC power source fails.
• The inverter detects a voltage drop on the off-line bypass and automatically turns on and
starts operation. The BYPASS LED will stop glowing.
• The inverter draws DC power from the connected battery which inverts it to AC power to
supply the load. The INVERT LED and 50/60HZ LED will start glowing green indicating the
inverter is operating normally.
• The inverter will keep operating until it detects that the AC voltage has been restored or
the DC power souce/battery is discharged.
TIP: YOU CAN ADJUST THE START-UP AND SHUTOFF VOLTAGE THRESHOLDS USING
INVERTERWIZARD
The AC voltage thresholds that the inverter detects in order to start and end operation can be
adjusted using InverterWizard. For more information, see the InverterWizard manual.
TIP: ENSURE THE BATTERIES HAVE ENOUGH CAPACITY TO POWER THE INVERTER
FOR THE EXPECTED LENGTH OF AC POWER FAILURE.
For example, a 2000-watt inverter running from 24 VDC input will draw ~100 amps. For 2 hours of
run time, the minimum required battery capacity is 280 amps-hours of capacity @ 24 VDC.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Analytic Systems Invertitore

Analytic Systems
Analytic Systems IPSi365 Manuale utente

Analytic Systems
Analytic Systems Pure Sine 300 Manuale utente

Analytic Systems
Analytic Systems IPS600 SERIES Manuale utente

Analytic Systems
Analytic Systems IPS2000 Manuale utente

Analytic Systems
Analytic Systems IPSi2400 Series Manuale utente

Analytic Systems
Analytic Systems IPSi305M-20-220ZAS Manuale utente

Analytic Systems
Analytic Systems IPSi1200 Series Manuale utente

Analytic Systems
Analytic Systems IPSi2400-125 Series Manuale utente

Analytic Systems
Analytic Systems IPSi505MW Manuale utente

Analytic Systems
Analytic Systems IPSi305MW Manuale utente