ANEP P4GU VoLTE Manuale di istruzioni

P4GU VOLTE
4G MOBILE NETWORK GATEWAY4G MOBILE NETWORK GATEWAY
EQUIPMENT FOR ELEVATORSEQUIPMENT FOR ELEVATORS
NT_ANEP_P4GU_VoLTE_EN_12-05-2022
www.anepstore.com

NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 2 / 48
SUMMARY
SUMMARY ........................................................................................... 2
GENERAL WARNINGS ....................................................................... 5
General Remarks .......................................................................... 5
DESCRIPTION ..................................................................................... 6
Main Features ............................................................................... 7
LEDS ................................................................................................... 7
INSTALLING ........................................................................................ 9
Tips for installation ........................................................................ 9
Consumption table ........................................................................ 9
Fixation ......................................................................................... 10
Inserting the SIM card .................................................................. 11
Installating the antenna ................................................................. 12
Remote alarm ............................................................................... 13
Connecting the power supply / bettery ......................................... 14
STARTING ........................................................................................... 15
PROGRAMMING BY PHONE .................................................... 16
How to use .................................................................................... 17
Roaming conguration .................................................................. 17
Setting the country ........................................................................ 17
Adjusting the Transmit/Receive Gain ........................................... 17
Setting the call codec ................................................................... 18
Telephone number for administration ........................................... 18
Programming password ................................................................ 18
Dialed Telephone Number Converter ............................................ 18
2G, 3G, 4G signal level measurement .......................................... 19
Setting the network type ............................................................... 19
Telephone number for notication ................................................. 19
Battery Alert .................................................................................. 19
Telephone line voltage ................................................................... 20
External power supply fault check ................................................ 20
Reading battery status .................................................................. 20
Restarting (rebooting) ................................................................... 20
Factory Reset ................................................................................ 20
SUITE

3 / 44
NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 3 / 48
SUMMARY
PROGRAMMING BY SMS .................................................................. 21
Message format ............................................................................ 21
Mode / Reading mode of use ....................................................... 22
Conguration / Désactivation of roaming ...................................... 22
Reading the Roaming status ........................................................ 22
Read / Set country code ............................................................... 22
Reading / Adjusting the transmitter gain ....................................... 23
Reading / Adjusting the receiver gain ........................................... 23
Reading / Setting the call codec ................................................... 23
Denition / Deletion / Reading of the administrator number ......... 23
Programming password settings .................................................. 23
Dialed Telephone Number Converter ........................................... 24
Entering / Deleting a pre-recorded number .................................. 24
Deleting all pre-stored numbers ................................................... 24
Playing pre-recorded Nos ............................................................ 24
2G / 3G / 4G signal level measurement ....................................... 24
Reading / Setting the type of network ............................................. 25
Denition / Deletion / Reading of the notication number .............. 25
Denition / Reading of the Tel. ANEP protocol ............................... 25
Entering / Reading ANEP protocol identier ................................... 25
Enabling / Disabling the battery charge level check ....................... 26
Reading the battery charge level check ......................................... 26
Voltage / Reading Telephone Line Voltage ..................................... 26
Enabling / Disabling external power supply control ........................ 26
Reading the external power supply control .................................... 26
Identifying the type of gateway ....................................................... 27
Reading battery status .................................................................... 27
Remote update [DATA at rate required] ........................................ 27
Restarting (rebooting) .................................................................. 27
Factory Reset ............................................................................... 27
SUITE

NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 4 / 48
SUMMARY
ADJUSTING THE GAIN ..................................................................... 28
AUTOMATIC PHONE NUMBER CONVERTER ................................ 29
MEASURE THE SIGNAL LEVEL ...................................................... 31
BATTERY ALERT ............................................................................... 32
EXTERNAL POWER FAILURE MONITORING ................................. 33
READING ADVANCED GATEWAY PARAMETERS .......................... 34
BATTERY STATUS READING ........................................................... 35
REBOOT .............................................................................................. 36
FACTORY RESET ............................................................................... 36
SERVICE .............................................................................................. 37
SIGNALING ......................................................................................... 38
TONES ............................................................................................. 38
CALL SIGNALING .......................................................................... 39
LEDS ................................................................................................... 39
GREEN - 2G / 3G / 4G network strength ........................................ 39
RED - Device status ........................................................................ 40
WHITE - Line status ......................................................................... 40
BLUE - Power status ....................................................................... 40
PROBLEM RESOLUTION ................................................................. 42
WARRANTY ....................................................................................... 43
SUITE

5 / 44
NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 5 / 48
GENERAL WARNINGS
GENERAL REMARKS
Pay close attention to the warnings contained in this section as they provide
important guidelines for achieving a safe installation, for correct use and
maintenance of the product.
• The appliance must be intended EXCLUSIVELY for the use for which it was
been designed and ANEP cannot be held responsible for any damage resulting
from improper use.
• The product has been designed in compliance with the standards, the
installation must be carried out inside compliant installations meeting
appropriate standards.
• Before carrying out any intervention inside or outside the product (cleaning,
maintenance, etc.) disconnect the appliance from the main power supply and
the battery.
• For any repair work, please contact our service exclusively after-sales SAVTEL.
• Install the product in a ventilated room taking into account the ventilation which
does not must in no case be obstructed.
• Do not install the product in a potentially explosive environment.
• Ensure that the product is installed according to the prescribed indications.
• Do not introduce objects, liquids or dust, do not use a spray inside the product.
• The packaging elements must not be left within the reach of children, because
they can be potential sources of danger.
• In order to capture a better 4G GSM network, install the gateway at the highest
• possible in the building, ideally in high machinery, otherwise at the top of
elevator shaft.
WARNING
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Electrical equipment must be compulsorily recycled
according to Directive n°2012/19/EU relating to waste
electrical equipment and Electronic (WEEE)

NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 6 / 48
DESCRIPTION
P4GU VoLTE is a device which is connected directly to a fixed telephone or a
remote alarm, makes it possible to make and receive calls via the mobile network.
For operation, a SIM card is required.
P4GU VoLTE has an internal backup battery (to be connected)
VoLTE
BATTERY
NI-MH 7,2V 800mAh
(To be connected)
LINE CORD
(Cord 2m)
ANTENNA
(cordon 2m)
GATEWAY
P4GU VoLTE
P4GU with
Power Supply Socket
réf : A-EA-022
P4GU with
2-WIRE Power Supply
réf : A-EA-023
OR
réf. ANEP
J-CA-049

7 / 44
NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 7 / 48
MAIN FEATURES
• Local programming via a telephone set [DTMF]
• Remote programming via SMS
• Roaming service management (roaming)
• Control of the absence of electrical network
• Remote firmware update (with data plan)
• Checking the battery charge level
• Power failure notification SMS
• Power restored notification SMS
• Battery exhausted notification SMS
• State of the power supply under ANEP protocol
• Fallback mode: connection to the 4G network, otherwise 3G, otherwise 2G
(voice only)
• Reading of 2G, 3G or 4G signal level
• Automatic converter of selected number
• Setting transmit and receive gains
• Remote reset
• Remote firmware update (internal software)
• Mobile network intensity signaling LED
• Device status LEDs
• Line status indicator LED
• Power status indicator LED
• Dual Band Module (European 4G Network)
• Transmit power 2W
• Input for direct 12Vdc power supply
• Input for transformer power supply. external 230Vac / 12Vdc
• External antenna (cable L = 2m) / (antenna with optional 10m cord)
• Plug-in or two-wire external adapter (input 230Vac 50 Hz, output 12Vdc 500mA)
• Dimensions: 140 x 96 x 28mm
• Weight: 220g
LEDS
The P4GU VoLTE device has 4 LEDs visible on the outside. For the meaning of
the flashing of each of the LEDs, consult the chapter "Signals"
(see pages 39 to 43).
Green LED: intensity of the mobile network in 2G, 3G or 4G
Red LED: device status
White LED: line status
Blue LED: power status

NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 8 / 48
A B
DEFG
H
LED green
GSM network intensity
LED red
device status
LED white
line status
LED blue
power supply status
C
> Remove the cover by acting on the upper side.
AANTENNA cable SMA connector
BSlot for the SIM card (standard SIM format 2FF)
C2G, 3G, 4G network reception level LED (green)
Device status LED (red)
Line status LED (white)
Power status LED (blue)
DRJ11 connector for connecting a fixed telephone or a remote alarm
EInput for transformer power supply. external 230Vac / 12Vdc
FTerminal for connecting a fixed telephone or a remote alarm
G Connection of the external 12V power supply
HConnecting the internal battery

9 / 44
NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 9 / 48
INSTALLATION
Tips for Installation
• The P4GU VoLTE gateway must be installed in a place where the radio
signal is sufficient for its correct use. In case that it is impossible to have of the
network with the 2m antenna, ANEP can optionally provide a 10 m antenna (ref.
A-EA-030), or a 5 m extension (ref : A-EA-025)
• It is important to have sufficient space around the device to optimized
maintenance operations.
• The P4GU VoLTE device cannot be installed outdoors because there is no
protection against atmospheric agents (rain, humidity, etc.) which could damage
it.
• Do not install the P4GU VoLTE device near other electronics devices (radio
or TV equipment, computers, television broadcasting systems, etc.) or magnetic
(credit card, tickets, etc.) which may be subject to Radiofrequences interference
from the device: the recommended minimum distance is 2.5 m.
• The P4GU VoLTE device should not be installed near medical devices .Its use
may harm hearing aids or pacemakers.
• Make sure that the use of the device at the place of installation is authorised.
Should not normally be installed in hospitals, aircraft, etc.
Consumption table
Power supply
10Vdc 12Vdc 13,8Vdc 10Vdc 12Vdc 13,8Vdc
(internal battery disconnected) (internal battery connected)
Handset on hook 30mA 30mA 25mA 40mA 60mA 50mA
Off-hook 90mA 80mA 70mA 100mA 105mA 90mA
Talk 130mA 115mA 110mA 140mA 135mA 130mA
SMS transmission 75mA 60mA 55mA 85mA 80mA 75mA

NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022 10 / 48
5mm
INSTALLATION
ATTACHMENT
Check the mobile network strength by the green network strength LED
(see chapter “Signals”, page 39)
Locate an area where the GSM signal is sufficient, ANEP recommends 3 fla
shes of the green LED.
Note: The network may vary depending on the telephone company.
• Make two holes of ø5 mm in diameter on the wall spaced between them by 50 mm.
• Insert the 2 dowels and tighten the screw up to 5 mm away from the wall.
• Insert the P4GU VoLTE device, through the two posterior eyelets, on the 2
screws from the wall.
50mm
ø5
ø5
Indice
Manuali Hardware di rete popolari di altre marche

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuale utente

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuale utente

Yudor
Yudor YDS-16 Manuale utente

D-Link
D-Link ShareCenter DNS-320L Manuale utente

Samsung
Samsung ES1642dc Istruzioni per l’uso

Honeywell Home
Honeywell Home LTEM-PV Istruzioni per il montaggio