Antrax SwitchBox-USB Manuale utente

antrax Datentechnik GmbH
[email protected] - www.antrax.de
SwitchBox-USB-USB
•relay version
•USB interface
Manual
12.07.2005
- 1 -
Hasenbrink 4, 32052 Herford, German Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
General
The SwitchBox-USB allows the input and switching off a electronic device via USB interface of
a PC. Timer-controlled switching operations b the parallel and serial interfaces via the free of
charge SwitchBox-USB service program (download on the antrax homepage)
Before first use of the SwitchBox-USB, please read this instruction manual or the help file
(found on our homepage). It contains information for the correct use and contains important
tips for the installation of the SwitchBox-USB. The manufacturer does not accept an liabilit
due to improper use of the unit. In this case all guarantee claims are invalid.
Use of the SwitchBox-USB
The SwitchBox-USB is intended for switching of resistive and inductive loads up to maximum
2000W (230V/8.5A) in dr and closed housing space and offices. Activation ma onl be set up
via the USB-bus. Operating instructions of the connected electronic devices and their safet
regulations must be respected.
Safety Instructions
Do not open the SwitchBox-GSM. It contains no parts to be serviced b ou.
Onl use the SwitchBox-GSM indoors and do not subject the unit to moisture or
humidit .
Onl connect the SwitchBox-GSM to properl installed 230V AC outlets.
Onl clean the exterior of the SwitchBox-GSM with a dr cloth after unplugging it
from the electrical outlet and removal of the interface cable.
Do not overload the SwitchBox-GSM above its load specification level. An
overload can lead to the SwitchBox-GSM being destro ed.
Do not use the SwitchBox-GSM in areas used b children.
Do not connect the SwitchBox-GSM to a computer that is alread switched on.
This can lead to computer components becoming damaged or destro ed.
Do not use the SwitchBox-GSM if one or several parts (case, cable, plug) are
damaged or damage ma be caused b its location (e.g., falling down).
The SwitchBox-GSM ma onl be repaired b authorized service personnel.
Onl connect electrical appliances that have no limit to their switched-on time (i.e.
all connected electrical appliances must be able to take continuous current without
sustaining damage in the case of a default to the permanentl “ON” position).
Never operate the SwitchBox-USB, if malfunction/error of the box ma cause
damage on people or material.
aution
The load circuit is switched about a single-pole electrical rela , therefore even when the
SwitchBox-USB outlet is switched to off there can still be a mains voltage on one of the
outlet sockets!
When the SwitchBox-USB is controlled via a PC/computer, this device determines the
- 2 -
Hasenbrink 4, 32052 Herford, German Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
switching state of the load circuit during and after booting of the s stem. Depending on
the behaviour of the used computer (or the BIOS), the operating s stem, device drivers
for the interfaces and other programs, while booting short-term or permanent switching of
the load is possible. The decisive switching state of the load is onl achieved b the start
of the SwitchBox-USB service program.
Ver fast ON/OFF switching sequences can be controlled with the SwitchBox-USB. The
duration of the switching c cles is to be adjusted to the controlled device. Not all
electronic devices tolerate rapid switching sequences.
Independent from the previous switching state the SwitchBox-USB will alwa s switch
OFF the connected 230V consumer after a “Power-ON”.
Package ontent
1 pcs. SwitchBox-USB
this manual
Software
The required driver ("SBOX_USB.DLL" and "USBaccess.DLL") an the free of charge software for
controlling the SwitchBox-USB can be downloaded from our web page at www.antrax.de
Installation of the SwitchBox-USB
Connectec the SwitchBox-USB to the USB-bus of the PC (the PC ma be switched ON
or OFF), however the SwitchBox-USB must not et be connected to a 230V socket.
The PC recognises the USB SwitchBox as "USB Switch" and "HID" (human interface
device).
Cop the two required drivers
- SBOX_USB.DLL
- USBaccess.DLL
in the s stem director (e.g. C:\WINDOWS\SYSTEM or C:\WINDOWS\SYSTEM32) to the
PC. Additional drivers are not requested!
Start the service program "SwitchBoxUSB.exe". This program consists of onl one file, no
entries in the registr or elsewhere are ever made b starting this program, there is no
"installation". The program can easil be copied to an subdirectories and be erased free
of residues.
The service program displa s all detected USB SwitchBoxes with their serial numbers.
Select the serial number ou want to switch from the list and use the "ON" / "OFF"
buttons for the selected box. The LED of the SwitchBox-USB changes color depending on
the current switching state: RED (=off) to GREEN (=on).
If ever thing works out fine: Plug the electronic device tot he SwitchBox-USB and
connect the SwitchBox-USB into a 230V outlet.
- 3 -
Hasenbrink 4, 32052 Herford, German Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Physical haracteristics
General:
•Protection class: IP20, in dr rooms onl
•Connector s stem: safet plug (CEE 714)
•Current switching state is indicated b green/red LED
•Load and control circuit have a safe electronic isolation over the switch rela
•Ambient temperature 0 ... +40°C
•Storage temperature -10 ... +70°C
Load ircuit:
•Operating voltage: 230/240V~ 50/60Hz
•Single pole electronic switch (rela )
•Maximum switching power: 2000W (8.5A at 230/240V)
ontrol ircuit:
•USB controlled
•Maximum power over USB, operating: approx. 150mA
•Each SwitchBox-USB has a unique serial number
E Marking
In accordance with the low-voltage and EMC directive.