Installation Instruction for AOK iT LED Parking Lot Light
Please read the installation manual carefully before installation and keep the manual for future
use.
Warning
1.Electrician must have related certifictes, knowledge and working experience. The work must be assigned
to each electrician based on their position and responsibility.
2.The lens of parking lot light modules are PC material, they may be scratched by any careless handling.
The parking lot light must be carefully protected in installtion, especially when the face of luminaire is put
downward, it needs to be protected with soft cloth or other protecting materials.
3.Installation must be proceeded when the electricity is shut off, no action be taken when there is electricity
connected.
4.Construction must be proceeded according to related regulations, including the tools and equipments
used. For example: working voltage range, Warning sign, flashing lamp, helmet, and working clothes etc.
5.Make sure the weather is suitable for high power electricity work when proceed construction.

Statement
1.Installation of parking lot light must be proceeded with cranes with lifting platform, warning sign and flash
lamp etc.
2.Installation and maintanence of Parking Lot Light must be proceeded when the electricity is off.
3.Maintenance must be procceded with professional staff.
Preparation for installation of LED parking lot light
Step 1: Open the package, remove the packing materials and take out the LED Lamp
Step 2: Take away the screws and stamping gasket from the Square mounting bracket as below picture shown.
Step 3
Drill holes on the square pole according to the hole position on the mounting bracket, make the driver cable on
the lamp go through the holes to the pole, fix the taken out screws from inside of the pole to the bracket, using
inner hexagonal screw driver to fasten the screws. As below picture shown.

Step 4
Wiring, connect the L,N,GND wires on the lamp to the L,N,GND cables on the poles accordingly
(Remark: US stanadrd Black: L, White: N, Green: GND; Eur Standard: Brown:L, Blue:N, Yellow Green: GND)
Step 5 The installed Parking Lot Light will be as shown in the picture

AOK Industrial Company Limited
Installation Instruction for AOK iT LED Parking Lot Light
Please read the installation manual carefully before installation and keep the manual for future
use.
Warning
1.Electrician must have related certifictes, knowledge and working experience. The work must be assigned
to each electrician based on their position and responsibility.
2.The lens of parking lot light modules are PC material, they may be scratched by any careless handling.
The parking lot light must be carefully protected in installtion, especially when the face of luminaire is put
downward, it needs to be protected with soft cloth or other protecting materials.
3.Installation must be proceeded when the electricity is shut off, no action be taken when there is electricity
connected.
4.Construction must be proceeded according to related regulations, including the tools and equipments
used. For example: working voltage range, Warning sign, flashing lamp, helmet, and working clothes etc.
5.Make sure the weather is suitable for high power electricity work when proceed construction.

Statement
1.Installation of parking lot light must be proceeded with cranes with lifting platform, warning sign and flash
lamp etc.
2.Installation and maintanence of Parking Lot Light must be proceeded when the electricity is off.
3.Maintenance must be procceded with professional staff.
Installation degree adjustment for Parking Lot Light with Wall mounting bracket
Loose and take out the M5 screws on the wall mounting bracket, adjust the bracket to desired degree, put the
screws back, fasten them as below picture shown.
Preparation for installation of Parking Lot Light
Step 1: Open the package, remove the packing materials and take out the LED Lamp
Step 2: Fix two setscrews on the wall according to the hole positon on the bracket, make the holes
on the bracket go through the setscrews, put nuts on the setscrews and fasten them. As below picture
shown.

Step 3
Wiring, connect the L,N,GND wires on the lamp to the L,N,GND cables on the poles accordingly
(Remark: US stanadrd Black: L, White: N, Green: GND; Eur Standard: Brown:L, Blue:N, Yellow Green: GND)
Step 4 The installed Parking Lot Light will be as shown in the picture

AOK Industrial Company Limited
Installation Instruction for AOK iT LED Parking Lot Light
Please read the installation manual carefully before installation and keep the manual for future
use.
Warning
1.Electrician must have related certifictes, knowledge and working experience. The work must be assigned
to each electrician based on their position and responsibility.
2.The lens of parking lot light modules are PC material, they may be scratched by any careless handling.
The parking lot light must be carefully protected in installtion, especially when the face of luminaire is put
downward, it needs to be protected with soft cloth or other protecting materials.
3.Installation must be proceeded when the electricity is shut off, no action be taken when there is electricity
connected.
4.Construction must be proceeded according to related regulations, including the tools and equipments
used. For example: working voltage range, Warning sign, flashing lamp, helmet, and working clothes etc.
5.Make sure the weather is suitable for high power electricity work when proceed construction.

Statement
1.Installation of parking lot light must be proceeded with cranes with lifting platform, warning sign and flash
lamp etc.
2.Installation and maintanence of Parking Lot Light must be proceeded when the electricity is off.
3.Maintenance must be procceded with professional staff.
Installation degree adjustment for Parking Lot Light with U shape
bracket
Loose and take out the M5 screws on the U shape bracket, adjust the bracket to desired degree, fasten and
fix the screws again as below picture shown.
Preparation for installation of Parking Lot Light
Step 1: Open the package, remove the packing materials and take out the LED Lamp
Step 2: Fix two setscrews on the wall according to the hole positon on the bracket, make the holes
on U shape bracket go through the setscrews, put nuts on the setscrews and fasten them. As below
picture shown.

Step 3
Wiring, connect the L,N,GND wires on the lamp to the L,N,GND cables on the poles accordingly
(Remark: US stanadrd Black: L, White: N, Green: GND; Eur Standard: Brown:L, Blue:N, Yellow Green: GND)
Step 4 The installed Parking Lot Light will be as shown in the picture
Questo manuale è adatto per i seguenti modelli
1
Altri manuali AOK Luce esterna
Manuali Luce esterna popolari di altre marche

Lindby
Lindby 9949029 Manuale utente

HEPER
HEPER DOGO Side LW6048.585-US Istruzioni per l'installazione e il funzionamento

HEPER
HEPER LW8034.003-US Istruzioni per l'installazione e il funzionamento

Maretti
Maretti VIBE S 14.6080.04.A Manuale utente

BEGA
BEGA 84 253 Manuale

HEPER
HEPER MINIMO Istruzioni per l'installazione e il funzionamento

LIGMAN
LIGMAN BAMBOO 3 Manuale utente

Maretti
Maretti TUBE CUBE WALL 14.4998.04 Manuale utente

Maxim Lighting
Maxim Lighting Carriage House VX 40428WGOB Manuale utente

urban ambiance
urban ambiance UQL1273 Manuale utente

TotalPond
TotalPond 52238 Manuale utente

Donner & Blitzen
Donner & Blitzen 0-02661479-2 Manuale utente