Product Introduction
The Aqara TVOC Air Quality Monitor can detect the
concentration and level of TVOC in the air, as well as
temperature and humidity. Aer it is bound with a hub,
it can use TVOC concentration or level, temperature,
and humidity changes as conditions of automation,
work with other smart home devices to implement
various smart scenarios, and send notifications to your
mobile phone.
* TVOC: Total Volatile Organic Compounds, organic compounds
whose saturated vapor pressure exceeds 133.32 Pa at room
temperature. Its boiling point is between 50°C and 250°C. It can
evaporate in the air at room temperature. Its toxicity, irritation,
carcinogenicity and smell will aect the skin and mucous
membranes and cause acute damage to the human body.
* An Aqara Zigbee 3.0 Hub is required. Some functions require
specific models of hubs. See www.aqara.com/support for more
details.
Reset Button
E Ink Display
01
Temperature and
Humidity Sensor Hole

Quick Setup
Add Device
1.
2.
3.
Before activating the accessory, please make sure
you have the Aqara Home app downloaded and the
Aqara Hub installed.
Please open the app, tap “Home” and then tap “+” in
the top right corner to enter the “Add Device
(Accessory)” page. Select “TVOC Air Quality Monitor”
and add it according to instructions in the Aqara
Home app.
Please see www.aqara.com/support for more
support.
* If adding fails, please move the hub closer to the product and try
again.
02
Sensor Hole
Battery Cover Opening

The network icon will not be displayed when the device
is oline and not in the searching state.
Network Icon (Sensor Display)
“Searching for network”icon:
“Connected to network”icon:
Page Switching
Double click the sensor button to switch between
multiple pages.
Installation Method
Eective Range Test: Aer it is bound with the hub, put
the device at the preferred installation location and
click the reset button of the device. If the hub makes
voice prompts, it indicates that the accessory can
communicate eectively with the hub.
03

Method 1: Place it directly on the desktop or other
preferred places without adhesive.
Method 2: Paste on a preferred place with adhesive.
Method 3: Paste on the surface of steel materials with
a magnetic sticker.
* Please make sure the surface of the pasting location is clean and
dry.
04

05
Specifications
Model: AAQS-S01
Dimensions: 41.6 ×76.0 ×14 mm(1.64 ×2.99 ×0.55 inch)
Wireless Protocol: Zigbee 3.0
Battery Model: CR2450 ×2
Operating Temperature: 0℃~ +50℃
Operating Humidity: 0~95% RH, no condensation
TVOC Detection Range: 0~25mg/m3
Temperature Detection Rage: 0 ~ 50℃
Humidity Detection Range: 0 ~ 100% RH
Zigbee Operation Frequency: 2405-2480 MHz
Zigbee Maximum Output Power ≤13 dBm
Warnings
1.
2.
3.
4.
This product is not a toy, please keep children away
from this product.
This product is designed for indoor use only.
Do not place this product near a heat source.
Do not attempt to repair the product by yourself. All
repairs should be performed by authorized
personnel.

Online Customer Service: www.aqara.com/support
Email: [email protected]om
Manufacturer: Lumi United Technology Co., Ltd.
Address: 8th Floor, JinQi Wisdom Valley, No.1 Tangling
Road, Liuxian Ave, Taoyuan Residential District,
Nanshan District, Shenzhen, China
06
5. This product is designed only for improving the
convenience of household life, and for status
notifications. If the user violates the product
instructions and this warning, the manufacturer is
not responsible for any risks and property losses
caused thereby.
EU Declaration of Conformity
Hereby, [Lumi United Technology Co., Ltd.]
declares that the radio equipment type [TVOC Air
Quality Monitor, AAQS-S01] is in compliance with
Directive2014/53/EU. The full text of the EU declaration
of conformity is available at the following internet
address: http://www.aqara.com/DoC/

Disposal of a battery into fire or a hot oven, or
mechanically crushing or cutting of a battery, that can
result in an explosion
Leaving a battery in an extremely high temperature
surrounding environment that can result in an
explosion or the leakage of flammable liquid or gas
07
CAUTION
Risk of explosion if the battery is replaced by
an incorrect type.
Dispose of used batteries according to the instructions.
Do not ingest battery, Chemical Burn Hazard.
This product contains a coin / button cell battery. If the
coin / button cell battery is swallowed, it can cause
severe internal burns in just 2 hours and can lead to
death.
Keep new and used batteries away from children.
If the battery compartment does not close securely,
stop using the product and keep it away from children.
If you think batteries might have been swallowed or
placed inside any part of the body, seek immediate
medical attention.
Indice
Lingue: