AUTOMATIC CLOSE (0-90 SECONDS ADJUSTABLE)
1. PRESS AND HOLD OPEN UNTIL ‘-’ IS INDICATED ON THE LED DISPLAY
2. PRESS OPEN TO INCREASE THE AUTO CLOSE TIME, PRESS CLOSE TO DECREASE TIME.
3. SET TIMER TO ‘0’, THE AUTOMATIC CLOSE FUNCTION WILL DISABLE.
4. PRESS SET TO CONFIRM THE SETTING
5. ADD 10 SECONDS PER NUMBER.
NOTE: AUTOMATIC CLOSE FUNCTION IS AVAILABLE ONLY WHEN THE DOOR IS IN FULLY
OPENED POSITION.
SETTING FOR OBSTRUCTION FORCE
IF THE DOOR MEETS AN OBSTRUCTION DURING CLOSING, IT WILL STOP AND
REVERSE ABOUT 15CM –20CM.
1. PRESS AND HOLD SET. THE LED WILL DISPLAY NUMBERS FROM 1 –4, WHEN
THEN NUMBER 3 APPEARS ON THE LED DISPLAY, RELEASE SET.
2. PRESS OPEN TO INCREASE THE OBSTRUCTION FORCE, THE MAXIMUM FORCE IS
LEVEL 9. PRESS CLOSE TO DECREASE FORCE, TO MINIMUM FORCE IS LEVEL 1.
3. PRESS SET TO CONFIRM.
PHOTO BEAM
CONNECT THE PHOTO BEAM –FOLLOW FIGURE. THE PHOTO BEAM OUTPUT SIGNAL MUST BE N.C.
SIGNAL
PRESS AND HOLD CLOSE UNTIL ‘=‘ IS INDICATED ON THE LED DISPLAY, RELEASE THE CLOSE, ‘11’ WILL
INDICATE ON THE LED DISPLAY.
PRESS OPEN, ‘H’ WILL BE INDICATED ON THE LED DISPLAY. PRESS SET TO CONFIRM.
THEN CONNECT THE PHOTO BEAM - FOLLOW FIGURE.
(NOTE: WHEN NOT USING PHOTO BEAMS, PLEASE CLICK THE ABOVE ACTION AND SET TO ‘11’ STATUS.
9. MAINTENANCE
•CHECK THE DOOR ONCE A MONTH. THE DOOR SHOULD BE CAREFULLY CHECKED FOR BALANCE. THE DOOR MUST BE
IN GOOD WORKING ORDER.
•THE AUTO-REVERSE FUNCTION SHOULD BE REGULARLY INSPECTED, AND ADJUSTED IF NECESSARY. FOR SERVICE,
CALL AN EXPERIENCED TECHNICIAN.
•WE SUGGEST FOR SAFETY REASONS, PHOTOCELLS TO BE USED ON ALL GATES.
•DISCONNECT FROM MAIN SUPPLY BEFORE REPLACING BULB.
•BE SURE TO READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO PERFORM ANY INSTALLATION OR SERVICE TO THE
DOOR OPERATOR.
•OUR COMPANY RESERVES THE RIGHT TO CHANGE THE DESIGN AND SPECIFICATIONS WITHOUT PRIOR
NOTIFICATION.