Artila Matrix-604 Manuale utente

Matrix-604
WinCE ARM9 Industry Box Computer
User Guide
Version 1.0
Copyright © Artila Electronics Co., Ltd. All Rights Reserved.


Table of Contents
1. Introduction................................................................................................................ 1
1.1 Features.............................................................................................................................. 1
1.2 Packing List......................................................................................................................... 1
1.3 Optional Accessory............................................................................................................. 1
2. Layout......................................................................................................................... 2
3. Pin Assignment and Definition.................................................................................. 3
3.1 USB Port............................................................................................................................. 3
3.2 Reset Button ....................................................................................................................... 3
3.3 Power LED.......................................................................................................................... 3
3.4 Ready LED.......................................................................................................................... 3
3.5 Link / Act LED ..................................................................................................................... 3
3.6 Serial Port LED ................................................................................................................... 3
3.7 Serial Port ........................................................................................................................... 3
3.8 Serial Console & GPIO Port................................................................................................ 4
3.9 Power Connector ................................................................................................................ 4
3.10 Ethernet Port....................................................................................................................... 5
3.11 Factory Default Settings...................................................................................................... 5
3.12 Power on and System Boot up ........................................................................................... 5
3.13 Initial Table.......................................................................................................................... 6
3.14 Network Settings................................................................................................................. 6
3.15 Use Account Manager ........................................................................................................ 6
3.16 Telnet Configuration............................................................................................................ 6
3.17 FTP Configuration............................................................................................................... 7
3.18 File System ......................................................................................................................... 7
3.19 Serial Ports Configuration................................................................................................... 7
3.20 Serial Console Configuration .............................................................................................. 8
3.21 GPIO Control....................................................................................................................... 8
3.22 Beep.................................................................................................................................... 8

3.23 update................................................................................................................................. 8
3.24 Web Page Directory............................................................................................................ 8
3.25 Reboot................................................................................................................................. 9
3.26 Remote Display Control...................................................................................................... 9
3.27 ActiveSync .......................................................................................................................... 9
3.28 Install Matrix-604 SDK...................................................................................................... 10
3.29 Install USB WLAN Dongle ................................................................................................ 11

Matrix-604 User Guide
‧1‧
1. Introduction
Matrix-604 is a WinCE ready, ARM9-based embedded computer. Its lower power and robust design
concept makes it an ideal industrial computer platform for harsh environment. The WinCE 6.0 OS is
pre-installed in the on-board Flash memory and the SDK for Microsoft Visual Studio 2005 on Artila FTP
is ready for your application development.
1.1 Features
ARM926EJ-S ARM Thumb Processor 400MHz w/MMU
32-KByte Data Cache and 32-KByte Instruction Cache
64MB SDRAM, 256MB NAND Flash on board
One 10/100Mbps Ethernet
Two USB 2.0 full speed (12Mbps) Host Ports
One software configurable RS-232/422/485 port and three RS-232/485 ports
One serial console port
5 programmable GPIO
9 to 48VDC power input
Pre-installed WinCE 6.0 and file system
SDK available on Artila FTP
Supporting WinCE Remote Display Control
Optional DIN RAIL mounting adaptor
1.2 Packing List
Matrix-604
Artila FTP includes SDK, and Remote Display Control software and example programs
1.3 Optional Accessory
CB-RJ45F9-150 (91-R45F9-150): Serial Cable (RJ45 to DB9 Female, 150cm)
CB-RJ2CON-100 (91-RJCON-100): Console Cable (RJ45 to DB9 Female, 100cm)
DK-35A (36-DK35A-000): DIN RAIL Mounting Kit
PWR-12V-1A (31-62100-000): 110~240VAC to 12VDC 1A Power Adaptor

Matrix-604 User Guide
‧2‧
2. Layout
10/100Mbps Ethernet
USB2.0 Host x2
Reset
9-48VDC Power
Serial Console & GPIO
P1/P2/P3/P4
Serial Ports
Power LED
System Ready LED
Ethernet LED
Serial Port LED
USB Client

Matrix-604 User Guide
‧3‧
3. Pin Assignment and Definition
3.1 USB Port
The USB port is an USB2.0 full speed host port. It can be used to expand the storage of Matrix-604.
USB client can work with ActiveSync to exchange file and data between PC and Matrix-604.
3.2 Reset Button
Press the “Reset” button to activate the hardware reset. Please always use “reboot” command to
reset Matrix-604. You should only use this function if the software reboot does not function properly.
3.3 Power LED
The Power LED will show solid green if power is properly applied.
3.4 Ready LED
After Power ON, Matrix-604 starts booting. Once system is boot up, the Ready LED will show solid
green.
3.5 Link / Act LED
When Ethernet port is connected to the network, Link/Act will show solid green and if there is traffic in
the Ethernet, this LED will flash.
3.6 Serial Port LED
These four dual color LEDs indicate the data traffic at the serial ports. When RXD line is high then
Green light is ON and when TXD line is high, Yellow light is ON.
3.7 Serial Port
The four serial ports can be configured as RS-232, RS-422 or RS-485 by software. They use RJ45
connector and the pin assignment are shown as following table.
Pin
RS-232
RS-422
RS-485
1
DSR
--
--
2
RTS
TXD+
Data+
3
GND
GND
GND
4
TXD
TXD-
Data-
5
RXD
RXD+
--
6
DCD
RXD-
--
7
CTS
--
--
8
DTR
--
--

Matrix-604 User Guide
‧4‧
Port 1: RS-232/422/485
RS-232: RXD, TXD, RTS, CTS, DSR, DTR, DCD, GND
RS-422: TXD+, TXD-, RXD+, RXD-, GND
RS-485: DATA+, DATA-, GND
Port 2/3/4:
RS-232: RXD, TXD, RTS, CTS, GND
RS-485: DATA+, DATA-, GND
3.8 Serial Console & GPIO Port
Serial console port is used for locally accessing Matrix-604 system using RS-232 port. The console
port uses RJ45 connector and is next to Ethernet port. Therefore please be careful to plug in the right
connector.
Port 0: RS-232: RXD, TXD, GND
Pin
Definition
1
PIO0
2
TXD
3
GND
4
PIO1
5
PIO2
6
PIO3
7
RXD
8
PIO4
Therefore you need to prepare or purchase the serial console cable (91-RJCON-100) in order to use
the serial console port. In addition to the serial console signal, the console RJ45 port also provides
GPIO (programmable I/O signal) function. The GPIO port is CMOS I/O and can be programmed as
digital input or output. Power up setting is digital input mode with 75K ohm pull up resistor.
3.9 Power Connector
Connect the 9 to 48VDC power line to Matrix-604. If the power is properly supply, the power LED will
show a solid green color.
Console
+
-

Matrix-604 User Guide
‧5‧
3.10 Ethernet Port
The Ethernet Port use RJ45 connector.
Pin
Signal
1
ETx+
2
ETx-
3
ERx+
6
ERx-
3.11 Factory Default Settings
LAN 1 IP Address: DHCP
Login: None
Password: None
Serial Console Port:
Baud rate: 115200
Data format: 8 Bits, No Parity, 1 Stop bit (N,8,1)
Flow Control: None
Terminal type: VT100
3.12 Power on and System Boot up
Once Matrix-604 is correctly power on, you can see the message prompt from the serial console port.
The system starts from the initial table and a batch file, autoexec.bat which is located at \NandFlash
will follow up. Therefore user can edit the autoexec.bat file or init table for your auto run program.
To skip the autoexec.bat, please repeatedly key $ (shift+4) right after system boot up.

Matrix-604 User Guide
‧6‧
3.13 Initial Table
WinCE uses initial table to decide the order of program/service to start after power on. You can use
init command to configure the initial table as follow:
Number 70 is Artila Manager and Number 71 is WinCE remote display control.
3.14 Network Settings
To configure the network setting by serial console, you can use command ifconfig as followed. To
check current network configuration, you can use command ipconfig.
3.15 Use Account Manager
To create user group and account, you can use command usrmgr. After user’s account and
password are created, user can add authentication in telnet and ftp function by using telnetdcfg and
ftpdcfg.
3.16 Telnet Configuration
Telnet is enabled without authentication as factory default. To disable or add authentication, please
use command telnetdcfg as follow:
Indice