ASA Electronics APS-201B Manuale di riferimento

Controller
Product Introductions
ASA ENTERPRISE CO.
2F., No.346, Sec. 6, Nanjing E. Rd.,
Neihu Dist.,Taipei City 114, Taiwan
Tel: +886-2-27900535
Fax: +886-2-27949952
Website: www.asa-tool.com
APS-201B APS-301B
APS-351B APS-201A
APS-301A APM-301A
APS-331A APM-301B
APM-301C
1

Table of Content
■Special Thanks to our customer
Thank you for choosing our light and powerful electric screwdrivers. To ensure the tool fully utilizes its
maximum performance and extend its life, please read this manual before use.
-Table of Content-
General Safety Warnings ..................................................................................................... 03
Read before use ..................................................................................................................... 04
Declaration of Conformity CE/Service ............................................................................... 05
Product information ............................................................................................................. 06
Operation ............................................................................................................................... 07
Troubleshooting ………………………………………………………………………......... 12
Assembly Drawing/Parts List …………………………………………………...………… 13
03
04
05
06
07
12
13
2

General Safety Warnings
■General Safety Warnings
WARNING : Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/or
serious injury.
Save all warnings and instructions for future reference.
■Work area safety
-Keep work area clean and well lit. Cluttered or dark areas invite accidents.
-Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases
or dust. Power tools create sparks which may ignite the dust or fumes.
-Keep children and bystanders away while operating a power tool. Distractions can cause you to lose
control.
■Electrical safety
-Power tool plugs must match the outlet. Never modify the plug in any way. Unmodified plugs and
matching outlets will reduce risk of electric shock.
-Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators.
There is an increased risk of electric shock if your body is earthed or grounded.
-Do not expose power tools to rain or wet conditions. Water entering a power tool/its adaptor will increase
the risk of electric shock.
-Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord
away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric
shock.
-When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
-If operating a power tool in a damp location is unavoidable, use a residual current device (RCD)
protected supply for its adaptor. Use of an RCD reduces the risk of electric shock.
■Personal safety
-Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use a
power tool while you are tired or under the influence of drugs, alcohol or medication. A moment of
inattention while operating power tools may result in serious personal injury.
-Prevent unintentional starting. Ensure the switch is in the off-position before connecting to power source
and/or battery pack, picking up or carrying the tool.
-Carrying power tools with your finger on the switch or energizing power tools that have the switch on
invites accidents.
-Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to
a rotating part of the power tool may result in personal injury.
-Do not overreach. Keep proper footing and balance at all times. This enables better control of the power
tool in unexpected situations.
-Dress properly. Do not wear loose clothing or jewelry. Keep your hair, clothing and gloves away from
moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.
3

Read before use
Read before use:
■Please read the following notices before use:
‧Set-up Notice
-The controller should be used in dry place indoor without the presence of dust and iron grindings.
-The controller should be positioned on a stable surface to avoid falling caused by vibration.
-The controller should be kept away from high voltage sources and noise generating sources to avoid
electromagnetic interference.
-No objects should be placed on the top of the controller. Keep its surrounding clear to allow heat
dissipation.
‧Caution during the operation:
-Please use the power supply with AC circuit where overload relay is included.
-The plug of the power cord is attached with ground pin, which must be connected to the socket equipped
with ground circuit to avoid electric shock.
-The plug of the power cord must be tightly plugged into the socket.
-For plugging and withdrawing the connecting cord of the controller and the screwdriver, please hold the
plug, do not pull the cable to avoid short circuit of the internal cable.
-It is directional when you plug the connecting cord into the driver or the controller’s socket. You have to
insert it in powerfully when align with guiding point in the socket; then twist it to fix it on the driver or the
controller. Thus it will reduce the occurrence breakage of connecting cord due to drag. Use the knob to fix
the cable with the controller. Please see the picture below:
-Please do not suddenly switch between forward and reverse when the electric screwdriver is in operation.
-Please use the electric screwdriver with under 80% of the rated maximum torque to avoid inaccurate clutch
escape (The rate maximum torque may vary with the flexibility of the fastened object). If you need to use
over 80% of the rated maximum torque, please be advised to use the screwdriver with higher torque.
‧Safety notice
-If notice smog, smell anything unusual, or hear any unusual noise from the controller, please stop using to
avoid any hazard. Turn off the power immediately and contact your nearest sales agent after no more smog
is found.
-Keep the two-stage switch in OFF position when the controller is not in use. Pull out the plug from the
power source socket when the controller is not in use for a longer period.
-Our controller is for ASAelectric screwdriver use only. Do not use it with other tools to avoid any hazard.
4

Declaration of Conformity CE/Service
■Declaration of Conformity CE
We (ASA Enterprise Corporation) declare under our sole responsibility that the products controller
described under this manual are in conformity with the following Directives/ or standardization
documents: Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU.
■Service
Have your controller serviced by a qualified repair person using only identical replacement parts. This
will ensure that the safety of the controller is maintained.
■Warranty
We offer one-year free repair service with this product. The warranty is valid for one year from the date of
purchase entered on the Product Information Form. Please note that this warranty policy does not apply to
the circumstances listed below and we will charge for repair or labor cost if necessary.
-Normal damage to the spare parts: relay (Switch or brake circuit).
-Improper use of the electric screwdriver may cause internal discontinuity between the two ends
(3P-3P/5P-5P/6P-6P) of the connector cord.
-The unit was not plugged to designated power source.
-Improper use or attempt to repair unit by user.
-Out of the warranty period or the user cannot present the manual.
5

Product Information
■Feature
-Universal power source: It is suitable for any power source ranges between 100-240VAC 50/60Hz.
-Stepless control: output stepless control and constant voltage makes the assembly of light, thin, short, and
small works more efficient and they are key features electron industry pursues after. The smaller the
screw, the higher locking and tightening is required. With this function, it can satisfied the requirements
of high precision and low inertia in both long and short screws fastening.
-Soft start: There is 0-1 sec. soft-start function inside the power supply. The speed of fastening will
gradually change from slow to fast motion during the operation. This lowers the risk of screw shaking
when fastening. (Corresponding model:APS-301B、APS-351B、APM-301B、APM-301C).
■Specification
Mode
lItem APS-201A APS-201B APS-301A APS-331A APS-301B APS-351B APM-301A APM-301B APM-301C
Input Voltage
(VAC) 100~240V 、50/60Hz
Output Voltage
(VDC) 9-19 V 20-30 V 20-33 V 20-30 V 25-35 V 20-30 V
Soft-start (sec) N/A N/A N/A 0 – 1 sec 0 – 1 sec N/A 0 – 1 sec 0 – 1 sec
Output Voltage
setting Stepless Control
Output Pin 5pin 5pin 3pin 5pin 5pin 5pin 5pin 6pin
Internal Signal
Output Switch-on/Brake No-Voltage contact
signal N/A Switch-on/Brake No-Voltage contact signal
External Signal
Output Switch-on Signal N/A Switch-on Signal
No. of
Screwdriver/power
supply 1 piece
Power (W) 38 W 60 W 56.1 W 60 W 59.5 W 75 W
Applicable Electric
Screwdriver models
BS-S050
BS-S100
BS-100
ASA-S1000M
BS-100F
BS-200
BS-250
BS-300
BS-400
BS-450
BS-2000
BS-3000
BS-4000
BS-4000F
BS-6000
BS-6500
AS-3636
AS-4636
AS-6636
ASA-S1000M
ASA-S2000M
ASA-S2500M
ASA-2000/S
ASA-3000/S
ASA-4000/S
ASA-4500/S
BS-6800 ASA-7000/PS
ASA-8000/PS
ASA-6000/PS
ASA-6500/PS
ASA-6800/PS
ASA-7500/PS
Dimension (mm) 164X64X42 mm 172X84X46 mm
Weight (g) 300 g 380 g
AC cable length (M) 1.8 M
Safety Standards CB,CE,UL(CUL),FCC,KC,ROHS,REACH
Accessories Small screwdriver, 2P/4P socket terminal 1 pieces, and AC cable
6

Operation
■Parts and functions
‧Speed setting
Turn the speed-setting screw through the hole on the side of the power supply with the small screw driver
(standard accessory).
-Turn clockwise 010 on the scale to increase the speed.
-Turn counter-clockwise 100 on the scale to lower down the speed.
APS-Series APM-Series
‧Soft-start setting (APS-301B /APS-351B /APM-301B/APM-301C ONLY)
Change the two-stage switch on the side of the power supply by hand.
-Switch to SLOW mode 0 1 sec. The speed gradually increases from slow to constant faster speed.
-Switch to FAST mode 0 0 sec. Constant speed without change.
7

Operation
‧Power setting andAC input socket (C13 specification)
-The input voltage of our power supply is ranged between 100-240VAC, 50/60 Hz. Please make sure you
use the correct voltage to avoid any damage to the power supply.
-Connect one side of the cable to the AC power socket and the other side to the AC input socket (C13
specification).
-Change the two-stage switch on the side of the power supply by hand.
On mode, the power supply will be switched on.
Off mode, the power supply will be switched off.
Two-stage Switch Top of the Power Supply AC input socket (C13 specification)
8

Operation
‧Indicator Light
Model
Item
APS-201A APS-201B APS-301A APS-331A APS-301B APS-351B APM-301
A APM-301
B APM-301
C
Switch-on ◎
After
switch on,
flash
orange
light three
times,
then turn
to green
light.
◎ ◎ ◎◎◎◎◎◎
Green
light
Brakes
No
light
No DC
voltage
output ◎◎◎◎◎◎◎◎◎
short
circuit
protection
◎◎◎◎◎◎◎◎◎
Flashin
g green Over
power
protection
◎◎◎◎◎◎◎◎◎
Red
light Brakes ◎◎◎◎◎◎◎◎
Flashin
g red
heating
protection
(temperat
ure set at
85~90℃)
◎◎
Indicator light
9

Operation
‧Output (DC) Plug
-Provide power to the electric screwdriver.
-Plug specification
Bottom of the Power Supply 3P connection 5P connection 6P connection
‧OUTPUT-A: Signal output terminal (see picture 1)
-A3 & A4: Switch on signal output. A3 and A4 will export no-voltage conduct signal when the electric
screwdriver switched on.
-A1 & A2: Shut-off signal output. When the electric screwdriver has reached its set torque and stopped,
no-voltage signal will be exported.
Picture1 Picture2
No-voltage conduct signal
high voltage specification: DC24V/400mA
.