5カメラの取付
Installation of Camera
6防水等級 IPX4 または IP66 の選択
Vent Hole "Open" or "Close" (IPX4 or IP66 Selectable)
カメラの取付に関しては追加説明書をご参考に収納してください。
内部の取付金具はカメラの機種により異なります。
*通常カメラに付属する AC アダプターは収納できません。
See appendix instruction for installation of camera.
Camera bracket varies from camera to camera.
A-PS2412 の取付方法
How to install A-PS2412
矢印の位置に1本のM4タッピングビスで取り付けます。
Install A-PS2412 to the slot pointed by using one(1) M4 tapping screw.
5975 Shiloh Road, Suite 103, Alpharetta, GA 30005
Tel 770-888-4674 · 1-888-988-4674
Fax 770-888-4675
URL : http://www.kk-asc.com
3-16-9, Toranomon, Minato-ku, Tokyo 105-0001, Japan
Tel +81-3-5473-7627
Fax +81-3-5473-7628
本機は出荷時、カバーの周りの通気孔を開いて外気とフィルターを通して通気しております。(IPX4)
これはカバーの曇りと内部温度の上昇を抑制することを目的としております。
しかし、海岸に極端に近い場合、湿度が極端に高い場所および寒冷地では通気孔を塞ぎ密閉する必要があります。(IP66)
(カバーの乾燥及びデフロスト効果の点よりファンを強制にする方がこのような環境では通常良いでしょう)
Vent hole are open for outside through sponge filter in order to avoid fog (IPX4).
You had better close these vent holes by silicon or rubber when you install it in coastal area and any other
extremely humid area (Usually continuous blower is recommended.)
Peel off sponge Filter Seal vent holes by using silicon or rubber.
CAUTION: TO REDUCE THE RISK OF
ELECTRICAL SHOCK, DO NOT EXPOSE
COMPONENTS TO WATER OR MOISTURE.
RISK OF
ELECTRIC SHOCK!
CAUTION
IMPORTANT SAFEGUARDS
1. Read Instructions - All the safety and operating instructions
should be read the unit is operated.
2. Retain Instructions - The safety and operating instructions
should be retained for future reference.
3. Heed Warnings - All warnings on the unit and in the
operating instructions should be adhered to.
4. Follow Instructions - All operating and user instructions
should be followed.
5. Electrical Connections - Only a qualified electrician should
make electrical connections.
6. Attachments - Do not use attachments not recommended
by the product manufacturer as they may cause hazards.
7. Cable Runs - All cable runs must be within permissible
distance.
8. Mounting - This unit must be properly and securely
mounted to a supporting structure capable of sustaining
the weight of the unit .Accordingly:
a. The installation should be made by a qualified installer.
b. The installation should be in compliance with local codes.
c. Care should be exercised to select suitable hardware
to install the unit, taking into account both the composition
of the mounting surface and the weight of the unit. Be
sure to periodically examine the unit and the supporting
structure to make sure that the integrity of the installation
is intact. Failure to comply with the foregoing could
result in the unit separating from the support structure
and falling, with resultant damages or injury to anyone
or anything struck by the falling unit.
LIMITED WARRANTY IN U.S.A.
ASC-USA, INC. warrants that products sold hereunder shall
be free from defects in materials or workmanship for a period
ONE (1) YEAR from the date of purchase by the original end-
user customer (the "Warranty Period").
ASC-USA, INC. makes no other warranty of any kind with
respect to this products, whether expressed or implied,
including without limitation, the implied warranty of fitness for
a particular purpose.
In the event of a breach of the above warranty, ASC-USA,
INC. shall its option, repair or replace said products, or refund
the purchase price paid therefor.
This is the exclusive remedy and ASC-USA, INC.'s sole
obligation with respect to the above warranty.
In no event shall ASC-USA, INC. be liable for any incidental
or consequential damages, as defined in section 2-275 of the
Uniform Commercial Code for a breach of this warranty.
ASC-USA, INC. shall repair or replace defective products
upon shipment of products prepaid to ASC-USA, INC. 5975
Shiloh Road, Suite 103, Alpharetta, GA 30005.
Repairs made by necessary by reason of accident, misuse
or normal wear shall be charged atASC-USA, INC.'s standard
rate. This warranty gives you specific legal rights, and you
may also have other rights which vary from state to state.
SAFETY PRECAUTIONS
The lightning flash with an arrowhead
symbol, within an equilateral triangle, is
intended to alert the user to the presence
of non- insulated "dangerous voltage" within
the product's enclosure that may be of
sufficient magnitude to constitute a risk of
electric shock to persons.
The exclamation point within an equilateral
triangle is intended to alert the user to
presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
UNPACKING
Unpack carefully. Electric components can be damaged if
improperly handled or dropped. If an appears to have been
damaged in shipment, replace it property in its carton and
notify the shipper.
Be sure to save:
1. The shipping carton and packaging material. They are the
safest material in which to make future shipments of the
equipment.
2. These installation and Operating Instructions.
SERVICE
If the product need repair service, the customer should contact
ASC-USA, INC. for authorization top return and shipping
instructions.
TECHNICAL SUPPORT
If technical support is needed, please contact:
ー9ー ー10ー