AuberInstruments,Inc. www.auberins.com
Page5of6
8.1. Control Configuration (CTRL)
Table1.ParametersinCTRLmenu.
Name Symbol Description Range Default Details
P P Proportional
band
0~9999 20 Unitindegrees.Largerthevalue,widertheband,
weakeractionfromtheproportionalcontrol.
IfP=1,I=0,D=0,itisON/OFFcontrolmode.
I I Integraltime 0~9999 100 Unitinseconds.Largerthevalue,weaker/slowerthe
actionfromtheintegralcontrol.
D D Derivative
time
0~9999 10 Unitinseconds.Largerthevalue,strongertheaction
fromthederivativecontrol.
T T Controlcycle
time
2‐120 2 Unitinseconds.
Hy Hy Hysteresis
band
0~999 2 Hysteresisband.OnlyappliestotheON/OFFcontrol
mode(i.e.,whenP=1,I=0,D=0).
OUTL OUTL Outputlow‐
limit
0~100 0% Minimumoutputlevel.Onlyappliestoautocontrol
mode
OUTH OUTH Outputhigh‐
limit
0~100 100% Maximumoutputlevel.Onlyappliestoautocontrol
mode
AT AT Auto‐tuning N,Y N Startauto‐tuningPIDparameters.Onlyappliesto
autocontrolmode
TF TF Timer
function
OFF,ON OFF OFF:disablethetimerfunction
ON:enabletimerfunction
TIME TIME Timersetting 00:00~
99:59
01:00 TimerunitinHH:MM
EO EO Ending
output
OFF,ON OFF Weathertoenableoutputafterthecount‐down
timerhasbeenreached.
OFF:disableoutputattheendofthetimercount‐
down.
ON:enableoutputtheendofthetimercount‐down.
8.2. System Configuration (SYST)
Table2.ParametersinSYSTmenu.
Name Symbol Description Range Default Details
Sn Sn Inputsensor
type
K,PT1K,
P100,
N50K
PT1K K:typeKthermocouple;
PT1K:PT1000RTD;
P100:PT100RTD;
N50K:50KNTCthermistor.
Pb Pb Probeoffset ‐20~
+20
0 Addanoffsettothetemperatureinputsignalfrom
thesensor.
C‐F C-F Temperature
unit
°C,°F °F DisplaythetemperatureinCelsiusorinFahrenheit.
PMOD Pmod Output
signaltype
TP,BF TP TP:time‐proportional;
BF:burst‐firingmode.