2
Conguration Mode
Conguration mode allows the device to be congured over an RS-232 port. The following list of commands
are accepted: See page 2
Commands:
Name Description Format Response
Enter Conguration Enables Cong Mode +++ n/a
Exit Conguration Returns to command
mode
[DEV=254;EXIT] n/a
Query Link Status Ethernet link up/down [DEV=254;NET;LINK?] [DEV=254;NET;LINK=UP]
Query IP Address Returns the SIG-0’s
current IP Address
[DEV=254;NET;LINK;IP?] [DEV=254;NET;LINK;
IP=10.0.0.2]
Query Server TCP
Port
Returns currently set
Server TCP Port
[DEV=254;NET;SERVER;PORT?] [DEV=254;NET;SERVER;
PORT=23]
Set Server TCP
Port
Changes the target
Server Port
[DEV=254;NET;SERVER;PORT=23] n/a
Reset Defaults Resets the SIG-0
to factory defaults
[DEV=254;RESET;DEFAULT] n/a
Reboot Device Reboots the SIG-0 to
implement change
[DEV=254;REBOOT] n/a
NOTE: All commands except “Enter Conguration” should be terminated by a carriage return. Some set
commands require a device reboot to take effect. Not all commands will have an associated response.
Full command set is available upon request. It is recommended to reboot the SIG-0 after any conguration
changes. This can be done serially, and after reboot, the device will be in Conguration Mode by default.
Communication
Serial Port (RS-232)
The SIG-0 communication bridge has the default device ID 254. It can send and receive serial commands
via RS-232 at 115200 Baud, 8-N-1, and full-duplex. The port may be set for null or straight using the switch
located on the side of the device opposite the microSD port. The port is a modular RJ-45 jack with the
following pinout:
RJ-45 Pinout:
Pin # Function Pin # Function
P1 Orange White - Ground P5 +12V DC Power
P2 Orange - Ground P6 Green - RX or TX
P3 Green White - TX or RX P7 Brown White - Ground
P4 +12V DC Power P8 Brown - Ground
Quick Start Instructions
• Connect the SIG-0 RS-232 port to another RS-232 device with a power injector (e.g. Model 1798).
• Ensure that settings have been congured correctly for both devices. (This can be done serially or via an
SD Conguration update.)
• Connect the SIG-0’s Ethernet port to the device to be controlled and power on both devices.
• Ensure that the Ethernet LEDs are both illuminated, and the power LED is blinking steadily. (The connected
network device will be assigned an IP address of 192.168.0.2 by DHCP, unless congured otherwise.)
• Communicate directly with the end device.