4
2 Safety precautions
2.1 Do not use or install the heater in places, where flammable vapours or gases or large
amounts of dust may form and accumulate.
2.2 Disable the heater, when the vessel is fuelled.
2.3 Disconnect the heater from its battery during repair works on the heater.
2.4 Take the safety precautions, which must be observed when working with an electrical
and fuel systems, when installing and dismantling the heater.
2.5 Do not connect the heater to the power circuit of the vessel, when the engine is
operating and there is no battery.
2.6 Do not disconnect the heater from power before the purge cycle ends.
2.7 Do not connect or disconnect connectors of the heater, when the heater is powered.
2.8 When the heater has been switched off, do not switch it on again for 5-10 seconds.
2.9 Do not step on the heater or put any objects on it and in it.
2.10 Do not cover the heater with clothing, pieces of fabric and so on, and do not place
such objects in front of the air intake pipe or inlet and output of the heated air.
2.11 For safety reasons, contact the service shop to troubleshoot the heater if it fails to
launch two times in a row.
2.12 In case of faults in the operation of the heater, contact specialised repair organisations
authorised by the manufacturer.
2.13 If the consumer fails to follow the requirements above, the warranty of the heater
becomes null and void.
2.14 To ensure reliable operation of the heater, switch it on once a month for 15-30
minutes, including in warm seasons of the year, when the heater is out of operation.
This action is necessary to remove any viscous film sediments on moving parts of the
fuel pump. Failure to do so may lead to premature failure of the heater.
2.15 Fuel in the system has to be changed at least once in a season.