Avenger JHS-A018-10KR Manuale utente

WARNING: Read and follow all warnings and instructions
in this manual to avoid personal injury or property damage.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Leave these instructions with the product
and retain for future reference.
OWNER’S MANUAL
ASSEMBLY AND OPERATING INSTRUCTIONS
Questions, problems, missing parts? Before returning to your retailer, call our
customer service department at 1-855-607-6557, 8:00 am - 4:30 pm EST, Monday
MODELS:
JHS-A018-10KR
SKU#: 130004
JHS-A018-12KRH
SKU#: 130005
Providing Factory Direct Pricing
and Exceptional Products
PORTABLE AIR CONDITIONER

www.factorybuysdirect.com M130004/5-012
TABLE OF CONTENTS
Safety Information .................................... 2
Additional Notes and Features ................. 3
Specications and Dimensions ................. 4
Components ............................................. 5
Installation ................................................ 6
Control Setting .......................................... 8
Protection Functions ................................. 9
Drainage Instructions .............................. 10
Maintenance ............................................11
Troubleshooting ...................................... 12
Appendix ................................................. 14
Warranty .................................................. 15
SAFETY INFORMATION
Thank you for purchasing the Avenger Portable Air Conditioner. Please
keep the manual for later review, and read the manual carefully before use.
NOTE: Please read and understand this entire manual before attempting to
assemble, operate or install the product.
Portable air conditioners exhaust large amounts of room air. Always ensure an
adequate supply of make-up air to operate efciently.
• Check available power supply and resolve any wiring problems BEFORE instal-
lation and operation of this unit. All wiring must comply with local and national
electrical codes and be installed by a qualied electrician. If you have any
questions regarding the following instructions, contact a qualied electrician.
• For your safety and protection, this unit is grounded through the power cord
plug when plugged into a matching wall outlet. If you are not sure whether the
wall outlets in your home are properly grounded, consult a qualied electrician.
DANGER: Do not leave this unit unattended in a space where people or animals
that cannot react to a failed unit are located. A failed unit can cause extreme over-
heating or death in such an enclosed, unattended space.
WARNING: Improper connection of the grounding plug can result in risk of re,
electric shock, and/or injury to persons associated with the appliance. Check with a
qualied service representative if in doubt that the appliance is properly grounded.
DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS WITH THIS UNIT.
If it is necessary to use an extension cord with this unit, use an approved "air con-
ditioner" extension cord only.
To avoid the possibility of personal injury, always disconnect the power supply to
the unit before installing and/or servicing.
The unit must be placed upright for a minimum of 2 hours before use.
PREPARATION: Before beginning assembly of product, make sure all parts are
present. Compare parts with package contents list. If any part is missing or dam-
aged, do not attempt to assemble the product.
1. The air conditioner is only suitable for indoor use.
2. All writing must comply with local and national codes to ensure that the ap-
pliance is properly grounded. If you have any question on electrical installation,
follow the instructions of the manufacturer, and if necessary, ask a professional
electrician to install it.
NOTES

www.factorybuysdirect.com 3M130004/5-01
NOTES CONT.
3. Place the appliance in a at and dry place and keep a distance of above 20
inches between the machine and the surrounding objects or walls.
4. After the air conditioner is installed, ensure that the power plug is intact and
rmly plugged into the power outlet. Place the power cord to prevent someone
from being tripped or pulling out the plug.
5. Do not put any object into the air inlet and outlet of the air conditioner. Keep
the air inlet and outlet free from obstructions.
6. When drainage pipes are installed, ensure that the drainage pipes are prop-
erly connected, and are not distorted or bent.
7. While adjusting the upper and lower wind-guide louvers of the air outlet,
handle gently to avoid damaging wind-guide louvers.
8. When moving the appliance, make sure that it is in an upright position.
9. The appliance should stay away from gasoline, ammable gas, stoves and
other heat appliances.
10. Do not install and use the air conditioner in the bathroom or other humid
environments.
11. Do not pull the plug to turn off machine.
12. Do not place any objects on the air conditioner.
13. Do not use insecticide spray or other ammable substances near the air
conditioner.
14. Do not wipe or wash the appliance with chemical solvents such as gasoline
and alcohol. When you need to clean the air conditioner, you must disconnect
the power supply, and clean it with a half-wet soft cloth. If needed, scrub with a
mild detergent.
FEATURES
1. Modern appearance, compact, simple, and elegant.
2. Cooling, heating (select models), dehumidication, air supply and continuous
drainage function.
3. Automatic swing louver incorporates automatic air swing function. The outlet
can be covered when the appliance is turned off to prevent dust from entering the
body.
4. LCD displays control panel. High-quality LCD remote control is equipped to
facilitate operation. The remote control can be placed on the back of the body.
5. Handles on both sides allow for ease of portability.
6. A cord wrap is provided on the back of the appliance to keep the cord safe and
out of the way.
7. Outdoor interface is set high to facility assembly and keep the smooth ow of
the heat pipe. Outlet connection for the hose is high at the back of the heater to
facilitate heat exit and efciency.
8. Air ltration capability.
9. Timing switch function.
10. Appliance protection function of automatically restarting the compressor after
three minutes if a power failure happens.

www.factorybuysdirect.com M130004/5-014
SKU#: 130004 SKU#: 130005
Product Weight 53 lbs 61 lbs
PRODUCT DIMENSIONS
SPECIFICATIONS
SKU#: 130004
SKU#: 130005
28.5" H
28.5" H
16" W
16" W
14" D
14" D

www.factorybuysdirect.com 5M130004/5-01
COMPONENTS
Control Panel Top Cover
Louver
Front Housing
Rear Housing
Casters
EVA Filter Housing
Handle
Rear Housing
Continuous Drainage Hole
Air Vent Cord Wrap
CON Filter Screen Air Inlet Grille
Drainage Hole
Power Cord Plug
(adjustable according to customer requirements)
Exhaust Pipe Assembly
Window Sealing Plate Assembly

www.factorybuysdirect.com M130004/5-016
WARNING: Before using the portable air conditioner, keep upright for at
least two hours.
INSTALLATION
The air conditioner can be easily moved in the room. In the moving process,
ensure that the air conditioner is in the upright position and the air conditioner is
placed on a at surface. Do not install and use the air conditioner in the bathroom
or other humid environment.
1. Install the heat pipe assembly (as shown in Figure 1):
Screw the heat pipe assembly (exhaust tting end) into the exhaust port on the
rear panel (counterclockwise).
2. Half open the window, and mount the window sealing plate assembly to the
window (as shown in Figure 2 and Figure 3); the assembly can be placed in hori-
zontal and vertical directions depending on your need.
2a. Pull various components of the window sealing plate assembly open, adjust
their opening distance to bring both ends of the assembly into contact with the
window frame.
Figure 1
Figure 2 Figure 3

www.factorybuysdirect.com 7M130004/5-01
INSTALLATION CONT.
3. Move the appliance with installed heat pipe and ttings in front of the window.
The distance between the body and walls or other objects shall be least .20
inches (as shown in Figure 4).
4. Elongate the heat pipe and snap the at end of the heat pipe into the elliptical
hole of the window sealing plate assembly (as shown in Figure 5 and Figure 6).
NOTE:
1. The at end of the heat pipe joints must be snapped into place.
2. The pipe cannot be distorted or have substantial turning (greater than 45
degrees). Keep the ventilation of the heat pipe unobstructed.
*IMPORTANT NOTICE:
The length of the exhaust hose should be 11"-59", and this length is based on the
specications of the air conditioner. Do not use extension tubes or replace it with
other different hoses as this may cause a malfunction. Exhaust must be unob-
structed; otherwise it may cause overheating.
Figure 4
Figure 5 Figure 6
20 in.
20 in.

www.factorybuysdirect.com M130004/5-018
CONTROL SETTING
OPERATING INSTRUCTIONS:
1. When the machine is powered on for the rst time, the buzzer will play power-
on music, and then the machine will get into standby status.
2. Power Key: Press the key to turn on and turn off the appliance.
3. Mode Selection Key: Press the key to switch between cooling, air supply,
dehumidication, and heating (single cold with no such function).
4. Up Key and Down Key: Press the two keys to change the set temperature or
timing set value, operate as follows:
• While setting temperature, press up key or down key to select the required
temperature (not available in air supply or dehumidication mode).
• While setting timer value, press up key or down to select the required cycle
time.
• Simultaneously press both keys to switch between Celsius and Fahrenheit.
5. Fan Speed Selection Key:
• In cooling and air supply mode, press the key to select high, medium, or low
fan speed operation.
• In heating mode, press the key to select high, medium, and low fan speed
operation.
• In dehumidication mode, pressing the key is invalid, and the fan will auto-
matically choose low fan speed operation.
6. Timing Key:
• When power is on, press the key to close timing; when power is off, press
the key to open timing.
• Press the key, when the timing symbol ashes, press up and down key to
select the required cycle time.
• Timing values can be set within 1-24 hours and the cycle time is adjusted
upwards or downwards by one hour.
Figure 7

www.factorybuysdirect.com 9M130004/5-01
CONTROL SETTING CONT.
OPERATING INSTRUCTIONS OF THE REMOTE CONTROL:
Key operation of the high-quality remote control are as follows:
1. Power: Press the key to turn on or turn off the machine.
2. Mode: Press the key to switch between cooling, air supply, dehumidication
and heating (single cold with no such function) mode.
3. Up: Press the key to increase temperature and timer.
4. Down: Press the key to reduce temperature and timer.
5. Fan: Press the key to select high, medium, and low fan speed output
circulation.
6. Timer: Press the key to set timer.
7. Louver: Press the key to open or close louver. Air ow of the air outlet can blow
at different angles.
8. : : Press key to switch between Celsius and Fahrenheit.
cool only remote control
SKU#: 130004
cool + heat pump remote control
SKU#: 130005
PROTECTION FUNCTIONS
1. Frost Protection Function:
In cooling, dehumidication or economic power saving mode, if the temperature
of the exhaust pipe is too low, the appliance will automatically enter into protec-
tion mode; if the temperature of the exhaust pipe rises to a certain temperature, it
can automatically revert to normal operation.
2. Overow Protection Function:
When water in the water pan exceeds the warning level, the machine will auto-
matically sound an alarm, and the LDC temperature display area will show "FL".
At this point, you need to move the drainage pipe connecting the machine or the
water outlet a drainage area to empty the water (details see Drainage Instruc-
tions at the end of this chapter). After the water is emptied, the machine will
automatically return to the original state.
Figure 8

www.factorybuysdirect.com M130004/5-0110
PROTECTION FUNCTIONS CONT.
3. Automatic Defrosting (heating and cooling models have this function):
• The machine has automatic defrosting functions: during defrosting, heating
symbol on the display screen will ash.
4. Automatic Thermal Protection:
• To protect the service life of the appliance, the machine has automatic ther-
mal protection in heating mode. During the protection period, the compres-
sor and the lower motor will stop operation and will automatically return to
normal heating state after the temperature of the appliance recovers.
5. Protection Function of the Compressor:
• To increase the service life of the compressor, it has a 3 minute delay boot-
ing protection function after the compressor is turned off.
DRAINAGE INSTRUCTIONS
1. Manual Drainage:
• When the appliance stops after the water is full, turn off the machine power
and unplug the power plug.
NOTE: Please move the appliance carefully, so as not to spill the water in
the water pan at the bottom of the body.
• Place the water container below the side water outlet behind the body.
• Unscrew the drainage cover and unplug the water plug, the water will auto-
matically ow into the water container.
NOTE: Set the drainage cover and plug aside within easy access. During
drainage, the body can be tilted slightly backwards. If the water container
cannot hold all the water, before the water container is full, plug the water
outlet with the water plug as soon as possible to prevent water from owing
to the oor or the carpet.
• When the water is discharged, plug in the water plug, and tighten the drain-
age cover.
NOTE: Restart the appliance after the water plug and drainage cover are
installed, otherwise condensate water of the machine will ow to the oor or
the carpet.
Figure 9
Questo manuale è adatto per i seguenti modelli
1
Indice