Avidsen 127041 Manuale utente

UNIVERSAL CONNECTED
CONTACTOR
HOME GATE
Ref.127041
www.avidsen.com
V3

TABLE OF CONTENTS
A - SAFETY INSTRUCTIONS 05
1 - OPERATING PRECAUTIONS 05
2 - WARNING 05
3 - MAINTENANCE AND CLEANING 05
4 - RECYCLING 05
B - PRODUCT DESCRIPTION 06
1 - KIT CONTENTS 06
2 - CONNECTED CONTACTOR 06
C - INSTALLATION 07
1 - INSTALLATION ON SLIDING GATE 07
2 - INSTALLATION ON SWING GATE 07
3 - GARAGE INSTALLATION 07
D - WIRING 8
E - CONNECTION 9
1 - INSTALLING THE MOBILE APPLICATION AND CREATING AN ACCOUNT 9
2 - CONNECTING THE CONTACTOR 10

UNIVERSAL CONNECTED CONTACTOR
EN33EN
F - USING THE PRODUCT 12
1 - USING THE PRODUCT VIA THE APPLICATION 12
2 - USING THE PRODUCT WITH GOOGLE HOME 13
3 - USING THE PRODUCT WITH AMAZON ALEXA 14
4 - SCENARIO AND AUTOMATION 14
4.1 SCENARIO 14
4.2 CREATING AN AUTOMATION 15
G- TECHNICAL AND LEGAL INFORMATION 21
1 - TECHNICAL CHARACTERISTICS 21
2 - RADIO CHARACTERISTICS 21
3 - WARRANTY 22
4 - HELP AND ADVICE 22
5 - PRODUCT RETURNS/AFTER SALES SERVICE 22
6 - EC DECLARATION OF CONFORMITY 22

EN 4

UNIVERSAL CONNECTED CONTACTOR
EN5
A - SAFETY INSTRUCTIONS
1: OPERATING PRECAUTIONS
• Read this entire manual before starting the
installation.
• Do not allow children to operate the product.
• Do not install this product outside a waterproof
housing
• Switch off the circuit breaker before working on
the product
2: WARNING
This product has been designed to control a dry
contact for a gate or garage door motor drive. Any
other use of the device shall not be covered by the
warranty or technical support. Avidsen cannot be
held liable for any use that does not comply with
the instructions in this manual and causes damage.
Children should be supervised to make sure that
they do not play with the device.
The operating principle of the connected contactor
triggers the motor drive based on a programmed
scenario; said trigger is not necessarily the user
(time condition, activation of another device, etc.)
It can also be used for remote triggering, without
direct visual access to the motor drive.
The specifications of the EN12453 standard enable
the 3 following use cases of the drive, as well as the
minimum levels of protection:
- Press activation with visible gate
Minimum level of protection: Force limiter only.
- Press activation with non-visible gate
Minimum level of protection: Force limiter and 2
pairs of photocells to protect the gate’s opening and
closing.
- Automatic control (automatic closure)
Minimum level of protection: Force limiter and 1 pair
of photocells to protect the gate’s automatic closing
Care should therefore be taken to ensure that
the motor drive installation is protected by the
equipment required for this purpose.
The Avidsen company may not be held liable
for any injury or property damage caused by the
triggering of the motor drive by the contactor.
3: MAINTENANCE AND CLEANING
The outside of the housing may have to be cleaned
from time to time.
• Switch off the circuit breaker before working on
the product.
• Do not use abrasive substances, substances
containing alcohol, thinners or other flammable
substances.
• Do not spray any product directly onto the unit.
4: RECYCLING
This logo denotes that devices no longer
in use should not be disposed of as
household waste. They are likely to
contain hazardous substances that are
dangerous to both health and the
environment. Return the equipment to
your local distributor or use the recycling collection
service provided by your local council.
Pour en savoir plus :
www.quefairedemesdechets.fr

UNIVERSAL CONNECTED CONTACTOR
EN 6
B - PRODUCT DESCRIPTION
1 - CONTENTS OF THE KIT
This product can operate any gate and garage door motor drive, provided said motor drive is equipped with
a dry contact control input. This product only has one dry contact output. Therefore your wiring will determine
the complete or partial opening of the gate (pedestrian mode). For the product to work, it must have a WiFi
connection.
2 - CONNECTED CONTACTOR
1Connected contactor
2Passive magnet
3Pre-wired magnet with extension
4Magnet brackets
5Grommet
6Screw + Nut
7Double-sided tape
8Double-sided tape
9Quickstart
1x 1 2x 1 4x 2
3x 1 5x 4 6x 2 9x 1
7x 2 8x 1
1
5
4
2
3
1Operation indicator
2Reset button
3230V connection
4Dry contact connection
5Magnet cable

UNIVERSAL CONNECTED CONTACTOR
EN7
C - INSTALLATION
Before the device is permanently installed, make sure it is within WiFi range of your router. If it is installed
outside WiFi range, you should install a WiFi repeater to boost the signal.
This product should not be installed outdoors. Position it in the housing of the gate motor drive or in a
waterproof junction box.
1 - INSTALLATION ON SLIDING GATE
Put the gate in closed position
Attach the passive magnet to the gate. Install the magnet bracket on the ground, leaving a gap of no more
than 13mm between the magnets. The magnets must not touch.
2 - INSTALLATION ON SWING GATE
Passive magnet
Grommet
.
Electronic
card
ContactorWaterproof
housing
Pre-wired
magnet
Install the pre-wired magnet on the panel on the side of the electronic card. Install the passive magnet on the
other panel, leaving a gap of no more than 13mm. The magnets must not touch.
3 - GARAGE INSTALLATION

UNIVERSAL CONNECTED CONTACTOR
EN 8
D - WIRING
Put the circuit breaker in OFF position before making the 230V connection.
Do not run the magnet and control cables in direct proximity to 230V cables. Risk of signal disruption due to
induction.
AC
I
N
230V AC L
N
Gate or garage door
motor drive
Avidsen
HomeGate
Dry contact
input

UNIVERSAL CONNECTED CONTACTOR
EN9
E - CONNECTION
This product only works with a 2.4Ghz frequency.
During pairing, make sure your smartphone is
connected on that specific frequency. If you are not
sure, check with your Internet service provider.
1 - INSTALLING THE MOBILE APP AND
CREATING AN ACCOUNT
Once the contactor is connected, follow the
instructions below to pair it.
Download the Avidsen Home app from the Android
Play Store or Apple App Store.
Launch the app and log in if you already have an
account. If not, press CREATE A NEW ACCOUNT
and let the application guide you.
After accepting the privacy policy, create an account
with an email address.
Procedure by email
In a few seconds, you will receive a validation
code in your email inbox. Enter this code to finalise
registration.
Note that this email may go into your spam folder.
If you do not receive a code before the countdown
has ended, press renvoyer (return) and check the
email address entered.

UNIVERSAL CONNECTED CONTACTOR
EN 10
E - CONNECTION
To complete your registration, set a password
between 6 and 20 characters long with letters and
numbers only, then press Terminé (Finished).
2 - CONNECTING THE CONTACTOR
As soon as it is switched on, the contactor will be
in pairing mode by default. Its indicator light starts
flashing until the pairing procedure is completed.
To start the pairing, press AJOUTER (ADD). Make
sure your phone is
connected on the 2.4GHz WiFi network of your
router. If you already have a device installed on the
application (e.g. IP camera, smart plug, etc.) click on
+ in the top right corner of the application.
Select the product you wish to pair and select Home
Gate.
Make sure the contactor is connected and its blue
indicator light is flashing. Otherwise, press the reset
button for 5s so that the blue indicator light starts
flashing. Select your 2.4GHz WiFi network (note:
your smartphone must be connected to the WiFi
network to which the plug will be connected), enter
your network password and press suivant (next).
IMPORTANT: If a location authorisation request
message appears, you need to
accept it for your Android or iOS device to receive
your WiFi.
IMPORTANT: This device is compatible with 2.4
GHz - WPA/WPA2 networks. Not compatible with
5 GHz WiFi
or with WEP encryption. Please check the WiFi
settings of your router or contact your Internet
service provider if you experience connection
difficulties.
Indice
Altri manuali Avidsen Accessori