Baldwin Boxall VIGIL3 Manuale utente

VIGIL3 Voice Alarm
Overview, Architecture and
Configuration
Manual name: VIGIL3 Overview, Architecture & Configuration
Issue: 2
ECR: 4494
Date of issue: December 2021

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
ii VIGIL3 Overview, Architecture & Configuration issue 2
© December 2021 Baldwin Boxall Communications Limited
Wealden Industrial Estate
Farningham Road
Crowborough
East Sussex
TN6 2JR
UK
Telephone: +44 (0)1892 664422
Email: [email protected].uk
Website: http://www.baldwinboxall.co.uk
This equipment has been designed and manufactured to conform to both CE &
UKCA requirements
Failure to use the equipment in the manner described in the product literature
will invalidate the conformity.
A “Declaration of Conformity” statement and a “Declaration of Performance” is
available on request.

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
VIGIL3 Overview, Architecture & Configuration issue 2 iii
Amendment Record ___________________________________ v
Proprietary Notice ____________________________________ v
Safety Information ___________________________________ vi
Comments_________________________________________ vi
Introduction
Scope _____________________________________________1
VIGIL3 Voice Alarm Features ____________________________1
VIGIL3 Voice Alarm Description __________________________2
Architecture
VIGIL3 Module Connections _____________________________5
Centralised vs Distributed / Networked Systems ______________6
Audio Input and Output Numbering _______________________8
Microphones ________________________________________8
Audio Priorities _____________________________________ 10
Voice Alarm (VA) Active Indication _______________________ 11
Fire Panel Inputs_____________________________________ 11
Cause and Effect Rule Engine____________________________ 11
Power Distribution___________________________________ 13
Real Time Clock_____________________________________ 14
Fault Indication
Configuration

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
iv VIGIL3 Overview, Architecture & Configuration issue 2

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
VIGIL3 Overview, Architecture & Configuration issue 2 v
AMENDMENT RECORD
Change Note
Number
Nature of Amendment Date of
Amendment
N/A Initial release: Issue 1 Feb 2020
ECR4494 Issue 2: Correct OS1 and OS2 max distances Dec 2021
PROPRIETARY NOTICE
All data and information contained within this manual is of a
proprietary nature with the exclusive title to the same held by
Baldwin Boxall Communications Limited. The possession of this
manual and the use of the information is, therefore, restricted
only to those persons duly authorised by Baldwin Boxall
Communications Limited.
Do not reproduce, transcribe, store in a retrieval system or
translate into any language, any part of this manual without the
prior permission of Baldwin Boxall Communications Limited.
In the interest of continual product development, Baldwin Boxall
Communications Limited reserves the right to make changes to
product specification without notice or liability. Use of Baldwin
Boxall Communications Limited products as critical components
in life support systems is not authorised except with express
written approval from Baldwin Boxall Communications Limited.

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
vi VIGIL3 Overview, Architecture & Configuration issue 2
SAFETY INFORMATION
Personnel who install, maintain or repair this equipment must
read the safety information below before starting work.
Voltages in excess of 30 Volts RMS or 50 Volts DC are considered
Hazardous and in certain circumstances can be lethal.
If Functional Testing, Maintenance, or Repair is to be completed
with the Mains Power (and/or battery backup) connected then
this should only be undertaken by personnel who are fully aware
of the danger involved and who have taken adequate precautions
and training.
This Manual contains Warnings, Cautions and Notes.
War nings describe potential threats to health or life, e.g.
WARNING
Before attempting to remove this component, ensure the Mains
Power Supply and Battery Backup have been disconnected.
Cautions describe potential threats to the equipment, e.g.
CAUTION
Notice must be taken of all cautions.
If a Caution is ignored the equipment may be damaged.
CAUTION: ELECTRO-STATIC SENSITIVE DEVICES
Observe the relevant precautions for the protection of Electro-
static Sensitive Devices when handling this equipment.
Notes are statements that are useful to the user in the context of
a particular section of the manual, e.g.
NOTE: Do not speak into the microphone until the "Speak Now" LED is
illuminated.
COMMENTS
Comments regarding the content of this manual are welcome and
should be addressed to hello@baldwinboxall.co.uk.
!!!

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
VIGIL3 Overview, Architecture & Configuration issue 2 1
1Introduction
1.1 SCOPE
This document is an overview of a VIGIL3 EN54 Approved Voice
Alarm System.
1.2 VIGIL3 VOICE ALARM FEATURES
The Vigil Voice Alarm System offers the following features;
• Up to 800 audio outputs
• Up to 400 audio inputs
• Up to 400 RS485 control ports
• 64 simultaneous site wide audio channels
• 254 fully monitored voice alarm messages (8GB storage in
.wav format)
• Site wide configuration from a single location
• User customisable graphical touch screen control
• Rules based Cause & Effect / Phased Evacuation engine
• Fully modular and expandable
• Built in fault tolerant networking

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
2VIGIL3 Overview, Architecture & Configuration issue 2
• Up to 24 band parametric equalisation
• Up to 1s audio delay
1.3 VIGIL3 VOICE ALARM DESCRIPTION
The VIGIL3 Voice Alarm range consists of a family modules that
when combined form a complete Voice Alarm and Public Address
System.
The following VIGIL3 modules are available;
• Amplifiers
• BV75D - 2 x 75W Amplifier Blocks
• BV150D -2 x 150W Amplifier Blocks
• BV300D - 2 x 300W Amplifier Blocks
• BV75Q - 4 x 75W Amplifier Blocks
• BV150Q - 4 x 150W Amplifier Blocks
• Battery Charger
• BVMBC - 10A battery charger
• Audio Routing
• BV3AOM8 - 8 Way Audio Output Module
• BV3AIM2 - 2 Way Audio Input Module
• BV3AIM4 - 4 Way Audio Input Module
•Networking
• BV3CIF - Copper Networking Interface
• BV3FIFM - Multimode Fibre Networking Interface
• BV3FIFS - Singlemode Fibre Networking Interface
• Interfacing
• BV3FPI - BV3AOM8 Fire Panel Termination Interface
• BVRDFPI - Fire Panel Interface
• BVRDCI - General Purpose I/O Interface
• Speaker Line Monitoring

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
VIGIL3 Overview, Architecture & Configuration issue 2 3
• BVRDACO - 10 way AC line monitoring module with
changeover
• BVRDNCO - 10 way AC line monitoring module
• BVRDADC - 10 way DC line monitoring module with
changeover
• BV3ADIM / BV3ADIS - Up to 10 way DC line
monitoring modules with changeover and A/B isolation
• BVLAM - 8 Way Impedance Line monitoring module
• Cooling and Power Distribution
• BV3MDPEFM - Exhaust Fan Module - required for all
systems using mains distribution panels below
• BV3MDP05F - 5 way mains distribution and fans,
supports up to 5 VIGIL3 amplifiers (2 x main frames)
• BV3MDP10F - 10 way mains distribution and fans,
supports up to 10 VIGIL3 amplifiers (4 x main frames)
• BV3EFM - Single main frame standalone cooling, no
power distribution
• Microphones
• BVRDTSM - Touchscreen voice alarm control
microphone
• BVRDTSMMON - External monitor for BVRDTSM
allowing user customisation of graphical interface
• BFM401-408 - Single to 8 way Fire Microphones
• BDM401-416 - Single to 16 way Paging Microphones
NOTE: BVRD Microphones are not supported by VIGIL3 Systems.
Please refer to the individual Hardware Installation Guides for
specific information about the above modules.

VIGIL3 Voice Alarm
Overview, Architecture and Configuration
4VIGIL3 Overview, Architecture & Configuration issue 2
Indice
Altri manuali Baldwin Boxall Sistema di sicurezza
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente