3.2. Command List
3.2.1. ?' or '/' prints a help file of commands to the terminal.
3.2.2. 'D' saves current GRI, TD, ECD, amplitude and slew data to eeprom. The stored values
will be recalled on power-up.
3.2.3. 'd' Recalls stored data from eeprom.
3.2.4. 'e'n sets negative ECD in uS. 0 to -10 uS. Shifts the envelope to the left.
3.2.5. ‘E'n sets positive ECD in uS. 0 to +10 uS. Shifts the envelope to the right.
3.2.6. 'i' prints out all output data.
3.2.7. 'l'nnn sets amplitude for TD1, TD2, and master to input.
3.2.8. 'L'n sets additional 10 dB attenuator. 1 = no atten, 0 = -10dB atten.
3.2.9. 'm'nnnn sets the GRI, 7980, 9960. etc.
3.2.10. 'q'n. If n = 1, sets quiet mode where only CSV numerical data is sent to terminal.
3.2.11. 'sx'nnn sets TD1 slew rate. 1 is fastest, 255 slowest slew.
3.2.12. 'sy'n sets TD1 slew rate.
3.2.13. ‘sX'n sets TD1 slew direction. 0 = decrement, 1 = increment.
3.2.14. 'sY'n sets TD2 slew direction.
3.2.15. 'S'n Starts or stops the TD slew. 0 = no slew, 1 = slew TD's.
3.2.16. 't'n sets Trig Out for master, TD1, or TD2. 0= master, 1= TD1, 2 = TD2.
3.2.17. 'v' prints out the software version loaded in the LCS-300.
3.2.18. 'x'nnnnnn sets the TD1 in tenths of a uS, 245678 = 24567.8 uS.
3.2.19. 'X'nnn sets TD1 amplitude, 0-255.
3.2.20. 'y'nnnnnn sets TD2 TD in tenths of a uS.
3.2.21. 'Y'nnn sets TD2 amplitude, 0-255.
3.3. Basic Command Examples
3.3.1. Set the time delay for TD1 to 27208.5 uS.: 'x272085'
3.3.2. Set time delay for TD2 to 41100.4 uS.: 'y411004'
3.3.3. Set master pulse group amplitude to 150: 'M150'
3.3.4. Set TD1 pulse group amplitude to 97: 'X97'
3.3.5. Set the ECD to +3 uS.: 'E3'
3.3.6. Set the ECD to -2 uS.: 'e2'
3.4. Advanced Command Examples
3.4.1. Set TD2 slew rate to decrement the delay by 25 nS every 10th GRI: Type 'sx10' to set
rate, then 'sX0' to set slew direction to decrement. To start the slewing the TD's, type 'S1.
Remember to press the 'enter' key after each command. Slew data for TD1 may be
entered if required.
3.4.2. Set the trigger at Trig Out connector to coincide with TD2: Type 't2'. Signal at the Trig
Out connector will be a positive pulse that occurs 13.6 uSec before the start of the TD2
pulse group.