Contents
Pre-Installation checks and procedures 6
Introduction 7
Technical Specication 7
Items Included 7
Protocols compatible with Matrix Interface 8
Menu Information 9
Data connection information KBD300A 10
Data connection information when using 2 x KBD300A 11
Remote Keyboard Mode 12
Matrix Interface DVR Control Mode 13
Tx1500 Control Protocol 14 - 15

6
Pre-Installation checks and procedures
Unpacking
Check packaging – Upon delivery of the unit, inspect the packaging for signs of damage. If damage has occurred, inform the
carrier and or the suppliers immediately.
Check Contents – After unpacking, check that all items are present. If any items are missing or damaged, contact the
equipment supplier.
Important Safety Precautions
Read Instructions – All relevant safety, installation and operating instructions should be read before attempting to install,
connect or operate the unit.
Retain Instructions – All safety, installation and operating instructions should be retained for future reference.
Heed Warnings - All warnings on the unit and in any relevant safety, installation or operating instructions should be
adhered to.
Cleaning - Switch off and unplug the unit from the power outlet before cleaning. Do not use liquid cleaners or aerosol
cleaners. Use a damp cloth for cleaning.
Attachments – Do not use attachments which are not recommended by the product manufacturers as they may cause a
hazard or damage the unit.
Water and Moisture - Do not expose this unit to water or damp.
Installation and mounting – Only install the unit in a suitable enclosure or mount.
Power Sources – This unit should only be operated from the type of power source indicated in the manufacturer’s label. If
you are not sure of the type of power supply you intend to use, consult your equipment dealer or local power company. For
units intended to operate from battery power or other sources, refer to operating instructions.
Object and liquid entry – Never push objects of any kind into the unit, as they may touch dangerous voltage points or short
out parts that could result in re or electric shock. Never spill liquid of any kind on or inside the unit.
Servicing – Servicing of the unit should only be undertaken by qualied service personnel, as opening or removing covers
may expose you to dangerous voltages or other hazards.
Damage Requiring Service – Servicing by qualied personnel should be carried out under the following conditions:
(a) When the power supply cord or plug is damaged.
(b) If liquid has been spilled, or objects have fallen into the unit.
(c) If the unit does not operate normally by following the operating instructions.
(d) If the unit has been dropped or the enclosure is damaged.
(e) If the unit indicates a distinct change in performance.
Replacement Parts – If replacement parts are required, ensure that only replacement parts recommended by the product
manufacturer are used.
Safety Check – Upon completion of any service or repairs to the unit, safety checks should be performed to ensure that the
unit is in proper operating condition.
Coax Grounding – If an outside cable system is connected to the unit, be sure the cable system is properly grounded.
Adhere to safety standards – All normal safety precautions as laid down by British Standards and the Health and Safety at
Work Act should be observed.

7
Introduction
The Matrix Interface allows control of both the Tx1500 and the FBM matrices via third party control equipment using the Tx1500
keyboard protocol. It also allows the supplied keyboards to be used over a back-to-back remote system when integrating with IP
Codecs, Fibre interfaces or radio link installations.
The Matrix Interface has three applications:
BBUS/IF Tx1500 MODE
Supports two main protocols: TX1000 RS232 control protocol
Tx1500 control protocol
Allows control of the Tx1500 and FBM matrices via third party control equipment.
- BBUS/IF REMOTE KEYPAD MODE
Allows the keyboards to be used remotely. Supports the use of IP Codecs, Fibre interfaces or a radio link. It reduces potential
latency and the introduction of data contention.
- BBUS/IF FBM MODE
Supports the use of all eight keypad addresses on the FBM and 4 on the Tx1500.
- DVR MODE
Supports the use of a connected DVR.
Technical Specifications
Power requirements: 12V DC 75mA
Features: • RS485/422 input
• To ease initial setup an OLED display show all the conguration information
• 5 pin screw terminal for serial inbound and outbound telemetry.
• Fully addressable 1 to 4 (1 to 8 when in FBM)
• Programmable default monitor selection from monitors 1 to 8
• RS422 inbound & outbound data Simplex / Duplex.
Engineering facilities: Inputs • 1 x 5-way screw terminal
• 1 x male 9-way D type
Outputs • 1 x 5-way screw terminal
Input protocols • Tx1500 control protocol
• Pelco D
• Pelco P
• Pelco ASCII
• BBV 422
Features: Visible OLED display for easy conguration
Dimensions 92mm (w) x 42mm (d) x 32mm (h)
Weight: 64g
Temperature range: 0°C - +40°C
Items included:
Unpack the unit carefully and check that all the items are present:
• Matrix Interface x 1
• Manual x 1
• 12Vdc 1A PSU x 1
If any items are missing or damaged, contact your equipment dealer.

8
Protocols compatible with Matrix Interface:
Inbound In bound data connection
BBV ASCII 9600,N,8,1 Full Duplex
Pelco ASCII 9600,O,8,1 Full Duplex
Pelco D 2400, 4800
9600,N,8,1
Simplex
Pelco P 2400, 4800
9600,N,8,1
Simplex
BBV 422 9600,N,8,1 Simplex
Outbound
BBV ASCII 9600,N,8,1
BBV BBUS 9600,N,8,1
Manual Version Date Changes
V1.26 15.5.18 Amends to diagrams
V1.25 23.4.18 Added DVR Mode
V1.24 20.5.17 Introduction of remote Tx1500 keyboard mode
V1.22 7.2.16
Additional drawing for two keypads
Menu Information
V1.1 29.2.18 Data connections for Pelco ASCII modied
V1.0 15.1.18 Initial Release

9
Menu Information
Indicates that the converter is powered but dormant
Indicates that the converter is transmitting
On power up or pressing the middle button the screen will display:
Software version
In bound protocol
Out bound protocol
If the middle button is pressed again it will enter the menu. The root
of the menu allows the selection of In bound protocol, the out bound
protocol & any protocol specic options.
When the converter is connected to the Matrix it will show:
Tx1500 Data received
Tx1500 Data OK
This means the matrix is talking to the converter and it understands the data.
When the converter is connected to the Pelco Kbd it will show:
Input Data received
Input Data OK
This means the converter is talking to the Pelco Kbd and it understands the data.
T
Right & Select in menu
Down & Open in menu
Left
MATRIX
INTERFACE
BBV V2.1
BBUS Interface
Pelco A to BBV 15K
Kbd address 1
Input Data received
Input Data OK
Tx1500 Data received
Tx1500 Data OK
BBV V2.1
BBUS Interface
Pelco A to BBV 15K
Kbd address 1
Input Data received
Input Data OK
Tx1500 Data received
Tx1500 Data OK
T
BBV V2.1
BBUS Interface
Pelco A to BBV 15K
Kbd address 1
BBV V2.1
BBUS Interface
Pelco A to BBV 15K
Kbd address 1
Tx1500 Data received
Tx1500 Data OK
BBV V2.1
BBUS Interface
Pelco A to BBV 15K
Kbd address 1
Input Data received
Input Data OK

10
+12Vdc
Rx+
Rx-
Gnd
Tx+
Tx-
Tx-
Tx+
Gnd
Rx-
Rx+
+-
PROTOCOL
CONVERTER
Gnd
BBV V1.0
BBUS Interface
Pelco A to BBV 15K
Kbd address 1
Input Data received
Input OK
Tx1500 Data received
Tx1500 Data OK
Data from the Tx1500 Matri x
Data to the Tx1500 Matri x
GR EE N R ED
Y E L LO W BLACK
ORANGE
B L UEW HI TE
BROWN
1 2 3 4 5 6 7 8
ON
Rear View of keypad
12V
ac/dc
MATRIX
INTERFACE
BBV V2.1
BBUS Interface
Pelco A to BBV 15K
Kbd address 1
Input Data received
Input Data OK
Tx1500 Data received
Tx1500 Data OK
Data connection information Pelco KBD300A
Indice
Altri manuali BBV Apparecchiature di registrazione
Manuali Apparecchiature di registrazione popolari di altre marche

Strymon
Strymon NIGHTSKY Manuale utente

Mitsubishi Electric
Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U Manuale utente

Tews Technologies
Tews Technologies TPMC465 Manuale utente

Honeywell
Honeywell Excel 50 Manuale utente

SeaLevel
SeaLevel COMM+8.LPCI Manuale utente

Arturia
Arturia AUDIOFUSE STUDIO Manuale utente