BEA LZR SIGMA Manuale utente

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 1 of 17
People-counting solution
PRODUCT INFORMATION 2
What's in the box 2
Labels 2
LED indications 3
Technical specications 3
HOW IT WORKS 4
How to connect - power 4
How to connect - network 4
INSTALLATION 5
Installation preparation 5
Installation location tips 7
Mounting options 9
Before you begin 9
Mounting 10
SETUP 11
ADDITIONAL FEATURES 14
INSTALLATION VERIFICATION 15
TROUBLESHOOTING 16
APPENDIX: SENSOR LOG 17
CONTENTS

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 2 of 17
Scan
me to
start
X0006F
FRONT FACE
PRODUCT
LABEL
COUNTING HEAD
QR CODE
SURFACE
MOUNTING BASE
SCREWS
SENSOR QR CODE
STICKER
PRODUCT INFORMATION
WHAT’S IN THE BOX
WHAT YOU'LL NEED
LABELS
MAC
ADDRESS
SENSOR
QR CODE
side of box
When installing multiple sensors at one site, It is considered best practice to log each sensor and its location.
Please use the log chart (Appendix) by adhering the extra sticker (loose in box) in the appropriate space and
log the site location.
• drill
• screwdriver, Phillips head
• wire cutters (optional)
• LZR-SIGMA app
• power (see page 4 for power options)
InformationColor
LZR®-SIGMA
IP : 192.169.1.2
user: H12345
password: password
MAC: 04:71:4B:51:23:45 SCAN ME TO START
H12345
TILT SCREW

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 3 of 17
= solid LED
= ashing LED
LED SIGNAL CAUSE ACTION
No internet connection
The ethernet conguration is wrong or no cellular network is available
Check the network connection
Check if port 8883 is opened
Device is not powered
Note that the LED can also be o when the
device is in normal operation
Check power supply
Communicating with the app or with
Sensorio.
Connected to the network
The device is communicating
Searching for network The device is connecting to the network
Learning Dene the max. limit on your right or left
Error If this occurs, please contact BEA.
Updating Connection to the device is impossible
Wait for update completion
At least one of the following port is not opened:
123 (UDP) / 22 (TCP) / 443 (TCP) / 8883 (MQTTS)
Check network settings with your IT support
See page 4 for more information on connecting.
PRODUCT INFORMATION
Technology LASER scanner, time-of-ight measurement
Emission characteristics - IR LASER Wavelength 905 nm ; average output power 0.05 mW; Class 1 (EN 60825)
Device dimensions 7.87 in [L] x 5.59 in [W] x 2.40 in [H] (elliptical)
(if mounted with recessed accessory : visible height 37 mm, invisible height 65 mm)
Temperature range -13 –131 °F if powered (storage temperature -31 –158 °F)
Humidity 0 - 95% non-condensing
Power 24 VDC ± 10% External DC power or PoE (IEEE802.3af)
Power consumption Max. 12 W/Peak - Average 6 W
Data transfer 3G/2G cellular, Ethernet (cable cat. 5/6)
Supported frequencies / Power GSM 850 - 824 to 849 MHz (Tx) - 869 to 894 MHz (Rx) - 2 W (Max. Power)
E-GSM 900 - 880 to 915 MHz (Tx) - 925 to 960 MHz (Rx) - 2 W (Max. Power)
DCS 1800 - 1710 to 1785 MHz (Tx) - 1805 to 1880 MHz (Rx) - 1 W (Max. Power)
PCS 1900 - 1850 to 1910 MHz (Tx) - 1930 to 1990 MHz (Rx) - 1 W (Max. Power)
Installation height 7 –18 ft
Counting width coverage Ratio [0.8 - 1.35] depending on mounting height (cf. sizer tool: www.meetsigma.io/sizer/)
Ports 123 NTP (UDP) / 22 SFTP (TCP) / 443 HTTPS (TCP) / 8883 MQTTS (TCP)
Video validation
(optional feature)
Resolution 160px x 120px, frame rate 15 fps
(for counting proof purposes only)
Counting data refresh rate /
granularity 1 min. (granularity 1 min.) to 24h (granularity 5 min.)
Protection degree IP53
Conformity
TECHNICAL SPECIFICATIONS
LED INDICATIONS

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 4 of 17
HOW IT WORKS
DETECTION
LZR-SIGMA uses laser time-of-ight technology to anonymously
detect people. The sensor precisely measures the shape of an
object passing through the detection zone to create a point cloud.
The point cloud is then analzyed in the sensor to determine if the
object is an adult or child to be counted, or a common object such
as a box, shopping cart, or stroller, and will be not be counted.
A person must cross the invisible detection zone to be detected by
the LZR-SIGMA. The counting data is transferred via the sensor's
network or cellular connection to a destination congured in the
Sensorio portal (sensorio.com).
CAMERA
The built-in camera in the LZR-SIGMA is for verication purposes only - it does not count people or record/transit video
continuously. For instance, if you want to ensure that your sensor is installed appropriately for optimal performance, you
can access the Sensorio portal (sensorio.com) to schedule and review counting proofs recorded by the camera.
The camera was purposely designed to record low-resolution video to preserve anonymity, and can be masked entirely for
applications in sensitive areas.
HOW TO CONNECT –POWER
HOW TO CONNECT –NETWORK
• IEEE802.3af compatible PoE switch or injector
• 24 VDC (±10%) power supply (p/n 08.0829)
LZR-SIGMA models:
• cellular (automatic connection)
• ethernet
LZR-SIGMA-ETH models:
• ethernet
ETHERNET INFORMATION:
When connecting via ethernet, ensure that the local network is set up
correctly to allow the LZR-SIGMA to connect to the Sensorio portal.
Ports 123 (UDP), 22 (TCP), 443 (TCP), and 8883 (MQTT) must be open.
The following sites must be accessible:
SFTP (Port 22)
sftp://drop.sensorio.com/upload
sftp:// 13.80.21.238/upload
HTTPS (Port 443)
https://callback.sensorio.com
http://httpbin.org/post
https://www.sensorio.com/
MQTTS (Port 8883)
eu.airvantage.net

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 5 of 17
INSTALLATION
BEA, Inc. recommends that you prepare for your installation to avoid unexpected hurdles while on the job.
1. Identify all of the entryways that will require sensors for counting coverage.
2. Review the environment of each entryway (using the following BEA mounting recommendations) to strategize sensor
placement.
a. Identify any obstructions to the detection zone (i.e. laser eld).
b. Identify any objects in/near the detection zone that could aect the ow of trac. Objects such as garbage
bins, sanitizer stations, magazine racks, or end caps can cause trac to stop within, stall within, and straddle the
detection zone, leading to a higher rate of miscounts. If possible, such objects should be moved away from the
entrance to improve counting accuracy.
c. Understand your minimum and maximum installation height.
• MAXIMUM HEIGHT: BEA, Inc. recommends that the sensor be installed at the maximum available height (no
higher than 18 ft) for the best accuracy. If the detection zone is too wide at the maximum available height, it
can be narrowed using the LZR-SIGMA mobile app.
• MINIMUM HEIGHT: To understand your minimum installation height (no lower than 8 ft) , you must rst know
the width of your desired detection area. Once the desired coverage is identied, check the chart below to
reveal your minimum installation height. You can also visit www.meetsigma.io/sizer to use the LZR-SIGMA
sizer tool to calculate minimum installation height.
• CONNECTED SENSORS: If you have reached your maximum available mounting height, but the detection
zone is not wide enough, your application will require the installation of multiple sensors to achieve a
wider detection zone (see Application Note 78.6034 for more information on installing multiple sensors).
To determine the recommended number of sensors to use for your desired detection zone, visit www.
meetsigma.io/sizer to use the LZR-SIGMA sizer tool.
d. Identify your power supply (location of outlets, DC supply, PoE network drops, etc).
e. Verify connectivity –network drop (ethernet) or cellular availability. To verify, power up the sensor and check that
the blue LED is illuminated.
INSTALLATION PREPARATION
MINIMUM INSTALLATION HEIGHT
THRESHOLD
WIDTH ≤40" ≤ 45″ ≤ 50″ ≤ 55″ ≤ 60″ ≤ 65″ ≤ 70″ ≤ 75″ ≤ 80″ ≤ 85″ ≤ 90″
MINIMUM
HEIGHT 90″ 93" 96″ 99″ 102″ 105″ 108″ 111″ 114″ 117″ 120″

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 6 of 17
INSTALLATION
INSTALLATION PREPARATION
UNSURE ABOUT YOUR APPLICATION? EMAIL BEA FOR A GUIDED INSTALLATION!
If your application has many nuances to be considered that makes you question sensor placement, BEA is here to help.
Before contacting BEA, please be sure to take photographs of the entryway in question - the more, the better!
Helpful tips for photos:
• Wide view of the immediate environment to show the ow of trac and any objects that could aect the ow.
See Figure 1.
• Angles to show depth of any obstructions above the entryway (e.g. air curtains, door hardware). See Figure 2.
Once you have all of your pictures, please email BEA at [email protected] to request a guided installation!
In your email, please include a detailed description of the intended application, what company you purchased your sensor
from (direct from BEA or other), attach your photos, and leave your contact information.
BEA will be in touch to schedule a guided installation!
FIGURE 1 FIGURE 2

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 7 of 17
HOW IT WORKS
INSTALLATION LOCATION TIPS
Scan
me to
start
X0006F
A
Detection area (location)
The threshold (i.e. counting area) should be appropriately covered. Measure the
desired threshold width across the space in front of the entrance (this is the space that
people will walk through). Beware of creating detection zone that is too wide, as you
could mistakenly be set up to count more than what is intended.
Sensor directionality
Observe the "A" and "B" markings on the sensor.
When wall mounting (or ceiling mounting near a wall), direction A must be pointing away
from the wall.
Proximity to door
The sensor should always be center-mounted above the desired detection zone (exception:
See Swing Doors section), and as close to the entryway as possible while avoiding
obstructions (ideally, no more than 12" from the threshold).
Corridor mounting
When the application calls for mounting in a corridor or hallway, you may
mount away from the door as long as the entire width of the corridor can be
covered by the laser eld.
TOP VIEW
ENTRANCE
max 12"
H
W

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 8 of 17
HOW IT WORKS
INSTALLATION LOCATION TIPS
Sensor angle
Mount perpendicular to the ow of foot trac.
Swing doors
closing side
1
2
closing side
1
2
closing side
closing side
Single leaf (no door closer):
When possible, install SIGMA on
the closing side in the middle,
outside the swing path (option 1).
When that is not possible, you can
install SIGMA on the opening side.
Make sure you place it right above
the leading edge (option 2).
Double leaf: Install SIGMA in
the center. Preferred side is the
closing side, outside the swing
path (option 1).
Single leaf (with door closer):
If a door closer is obstructing the
view, simply oset the mounting
location nearer to the leading
edge.

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 9 of 17
INSTALLATION
MOUNTING OPTIONS
BEFORE YOU BEGIN
LZR-SIGMA can be mounted in 3 ways:
• surface-mounted to the ceiling
• recessed into the ceiling
• surface-mounted to a wall
See following page for mounting instructions.
WALL SURFACE-MOUNT
CEILING RECESSED-MOUNTCEILING WALL-MOUNT
The Mini Bracket (10MINIBRACKET) can also be used in applications that will require the
sensor to extend from the wall to avoid obstructions.
See User's Guide 75.5799 for more information.
BEA highly recommends downloading the LZR-SIGMA mobile app and registering your account before you
begin the mounting process.

©BEA | Original Instructions
75.5929.01 LZR-SIGMA 20210630 Page 10 of 17
INSTALLATION
MOUNTING
6. Secure the base to the ceiling.
5. If necessary, a piece of the base can be removed
with a cutting tool.
"CLICK"
4. Pass the cable through the base.
3. Remove the counting head by unclipping it.
Caution – Do not
open the counting
head as it may
result in hazardous
radiation exposure.
Scan
me to
start
X0006F
8. Connect the cable to the counting head
Clip the counting head to the base and close SIGMA.
"CLICK"
"CLICK"
CLASS 1
LASER PRODUCT
7. Or use BEA’s wall mounting accessory to
secure to the wall.
1. Open SIGMA. 2. Determine directionality (see page 7).
Scan
me to
start
X0006F
Altri manuali per LZR SIGMA
1
Indice
Altri manuali BEA Accessori

BEA
BEA SUPERSCAN-T Manuale utente

BEA
BEA IXIO-DP1 Manuale utente

BEA
BEA VIO-ST Manuale utente

BEA
BEA Jamb Style PBJ Series Manuale utente

BEA
BEA EAGLE 6+DRO Istruzioni operative

BEA
BEA Eagle HM Manuale utente

BEA
BEA IS40P Manuale utente

BEA
BEA ACTIV8 THREE PULSE Manuale utente

BEA
BEA IXIO-ST Manuale utente

BEA
BEA IRIS Manuale utente

BEA
BEA Superscan Manuale utente

BEA
BEA FOCUS Manuale utente

BEA
BEA SUPERSCAN-T Manuale utente

BEA
BEA CRYSTAL Manuale utente

BEA
BEA Iris Overhead Safety for Door Manuale utente

BEA
BEA PBR45 Series Manuale utente

BEA
BEA Falcon Manuale utente

BEA
BEA Eagle HM Manuale utente

BEA
BEA MW6 Manuale utente

BEA
BEA CGS-MF Manuale utente