Befour PS-6615 Manuale utente

Professional
Portable Scale
INSTRUCTION MANUAL
PS-6615
“ The BEST in scales
and portable scoring systems.”

2
Table of Contents
Introduction ......................................
Cautions & Warnings .......................
Assembly Instructions
Before Assembly ...........................
Assembling the PS-6615 …...…....
Mounting Bracket ……………..….
Battery Installation ........................
Leveling the Platform ...................
Operation Instructions
Weighing Quick-Start ....................
Console Keypad ...........................
Special Features ...........................
Using the Pro-BMI Function …......
Using the Tare Function …..…......
Using the Recall Function ............
Changing Display Units ................
Programming Auto-Off Time .........
Programming Time & Date ……....
Battery Life Indicators ...................
User Setting Options ….…………..
Calibration .....................................
Care and Maintenance
Cleaning .......................................
Troubleshooting ............................
Cable Replacement ………………
Warranty
Model PS-6615
Warranty .......................................
Obtaining Service …………...........
Owner Record ..............................
Specifications
Model PS-6615
Specifications ................................
Transmitting Data
How to Transmit Data …………….
Optional AC Power Operation ......
3
3
4
4
5
5
5
6
6
7
8
9
9
9
10
10
10
11
12
13
13
13
14
14
14
15
16
16

3
Introduction
The Befour, Inc. line of electronic
portable scales uses the most
sophisticated microprocessor
technology available. Each precision
instrument is designed to provide
accurate, reliable and repeatable
weight measurements, as well as
many other features that make the
weighing process simple, fast and
convenient.
This operations manual contains
instructions for use of this scale. In
order to achieve satisfactory results,
the operator must read this manual
thoroughly before using this scale.
If any questions arise regarding this
scale or its use, please contact
Befour, Inc.
Failure to comply with the following may
void the warranty on the scale.
To ensure proper operation of the
Model PS-6615 electronic scale, this
operator’s manual should be
reviewed carefully before operation.
Keep this manual available for future
reference and also for use in the
orientation of new personnel.
If the scale becomes damaged, it
should not be used until properly
serviced. All repairs should only be
performed by Befour, Inc.
Scales are designed for static
weighing only. No scale should be
used for human or object transfer.
Do not gas sterilize or autoclave the
scale.
Do not place liquids on top of the
readout console.
Do not exceed the weight limit of
500 lbs. (225 kg.)
Scales contain delicate sensors.
Do not bang into doors, elevators,
etc., as damage may result.
Cautions & Warnings

4
ASSEMBLY INSTRUCTIONS
Before Assembly
Carefully inspect the carton for shipping damage before unpacking. If
significant damage is found, keep all packaging and contact your shipper or
Befour immediately. Claims must be filed with the shipper as soon as
possible after receipt of damaged goods.
Carefully unpack the components from the shipping container. Your
scale has been shipped in one (1) carton and contains the following items:
Scale Platform with leveling feet installed
Control Console
Four (4) D-cell alkaline batteries
If the optional AC adapter is ordered with the scale, the adapter will be
included in the shipping carton with the other components.
Assembling the Scale
1. Carefully open shipping carton, platform is packaged with leveling feet facing
upwards.
2. Remove console and set it nearby.
3. Remove platform and uncoil the cable. Place platform on the floor and
position as to minimize the potential for tripping over any cables.
4. Connect the cable to USB platform port receptacle on right side of console
(see Fig. 4). The silver label side of the connector should be facing up.
Teardrop holes
Figure 1: Wall Mounting Holes Figure 2: Table-top Position

5
Leveling the Platform
To level or adjust the height of the scale platform, carefully lift the platform and
adjust the leveling feet by screwing them in or out as needed. When leveled
properly, the scale should rest evenly on all four feet.
NOTE: Use caution when using scale on shag carpeting or similar surfaces. An incorrect
reading will result if the platform touches the floor or carpeting.
Mounting Bracket
Battery Installation
This scale is powered by four (4) disposable D-cell alkaline batteries and features
Befour’s exclusive ECO Weigh system that will provide 100,000+ weighings.
Use the following procedure when installing a new set of batteries:
1. Using a medium Phillips screwdriver, loosen the two screws on the left side of
the control console.
2. Gently slide the battery tray out until it stops,
about 3 inches.
3. Remove old batteries if necessary.
4. Insert new batteries as shown on the bottom of
the tray.
5. Slide tray back into control console and
tighten the screws to secure closed. Figure 3: Battery Tray
NOTE: Do not attempt to slide the tray out past its stops. When replacing old batteries,
always use four fresh ones.
A mounting bracket is pre-installed on the back side of the display console You
have three options to view your display console.
Option One: Console Flat on Surface
The console can lay flat on any surface. The wire arm should be flat against the
console bottom as show in Fig. 1.
Option Two: Wall Mounted
The bracket has two teardrop shaped holes used to mount the console to a wall
(Fig 1). You will need to drill two holes 5-3/4” apart. We recommend using wall
plugs and screws and leaving a 1/8” gap from screw head to the wall. Position
the console so the screw heads align with the large opening in the teardrop
holes and lower into place.
Option Three: Table-top Mounted
Rotate the wire arm until it is locked into the slots in the plastic bracket. The
console can now be positioned as shown in Fig. 2.

6
OPERATION INSTRUCTIONS
1. Depress ON/ZERO button.
2. Wait until “0.0” appears on display.
3. Step on scale.
Weighing Quick-Start
Console Keypad
The CX7 console has seven buttons. Note that some buttons perform more than
one function.
ON/ZERO: Depress to turn scale on or reset to zero.
MENU: Depress for advanced functions such as programming the clothing
deduction for the Pro-BMI calculation.
RECALL: Depress after the subject has stepped off the scale to recall weight.
“PRIOR WT” displays on the console and locks the scale so that no
further weighing can take place. While a person or object (> 6 lbs.)
is on the scale platform, depress RECALL to reweigh the subject.
LB/KG: Depress to switch between pounds mode and kilograms mode.
TARE: Depress to activate the Tare function which will subtract the weight of
the person or object on the scale.
HEIGHT: Depress to lock-in weight and to enter height value via keypad. BMI
will display automatically.
TRANSMIT: Transmit data to a computer. With optional equipment, the scale can
send data to a printer or to a wireless device.
AC Port
Data Port
Platform Port
Figure 4: Display Console

7
Special Features
The scale comes standard with these special features.
1. Auto-Zero: The scale will automatically display “0.0” when turned on. If the
display reads between “-1.0” and “1.0” at any time, regardless of what is on the
platform, the scale will automatically reset to “0.0” after 8 seconds.
2. English/Metric Readout: With normal operation, you may switch the display
units between kilograms and pounds at any time before or after a weighing.
When turned on, the scale will display the last used unit of measure. (See pg 9)
3. Smart View Display: The CX7 console shows only the information you want:
weight only or weight, height, and BMI.
4. Body Mass Index Calculator with Clothing Deduction: When calculating body
mass index, a clothing deduction can be user-programmed from 0.0 to 6.0 lbs.
Factory setting is 2.5 lbs. (See pg 8)
5. MotionLock Technology: In most cases the scale will display a true, accurate
weight based on a series of consistent and stable measurements. However, if a
person or object is moving on the platform, the scale may not achieve consistent
readings that are required to give a “stable” weight. This condition is indicated by
moving dashes on the display. If movement on the platform continues for seven
seconds, the scale will automatically activate the MotionLock feature and
“AVG WT” will be displayed on the console.
Because of the movement on the platform, average weight indicates that the
scale was not able to achieve a true measurement in line with the listed accuracy
specification. However, the average weight deviation from the true weight of a
person or object will be minimal, based on the severity of the motion during the
weight reading.
6. Auto-Off: As a battery saving feature, the scale will automatically turn off when
not being used. The Auto-Off feature does not apply to 120V AC power use. The
length of the Auto-Off timeout is programmable by the user. (See pg 10)
7. Always-On: As a time saving feature, the scale can take normal weighings
without the need to press any buttons. Simply stand on the scale and the weight
will be displayed within seconds. (See pg 11)
8. Tare: An object weighing more than 1.6 lbs. (ie. cane) can be subtracted from the
total weight to determine net weight. (See pg 9)
9. ECO Weigh: Befour’s exclusive ECO Weigh battery management system
provides many more weighings (100,000+) per set of batteries than other brands
of scales (5 x when compared to other D cell powered scales, 10 x compared to
C cell powered scales, and 50 x compared to AA celled scales). Over the life of
the scale, the savings from battery replacement costs (in both batteries, and more
importantly, time) are substantial.

8
Clothing Deduction
Your Pro-BMI scale has been preset with a clothing deduction of 2.5 lbs. This
level can be programmed from 0.0 to 6.0 lbs.
1. Depress ON/ZERO and wait for “0.0” to display on the readout console.
2. Hold MENU button down and depress the RECALL button. “Set-0” will be
displayed along with the up and down arrows; the “0” will be flashing.
3. Depress the button until “Set-4” appears; depress ENTER button.
4. The current clothing deduction will be displayed (i.e. “2.5”). Use the and
keys to set the desired value; press ENTER to advance to the next digit.
5. Press ENTER when complete to save and return to normal weighing.
Using the Pro-BMI Function
When using the scale, the Body Mass Index (BMI) of a user can be calculated.
The height of the user must be entered to correctly determine BMI. The Pro-BMI
function operates in both pounds (height input in inches or feet and inches) and
kilograms (height input in centimeters).
Figure 5: Input height display (inches format)
Figure 6: Body Mass Index display
Entering Height
1. Turn the scale on and wait for the display to read “0.0”.
2. Stand on scale platform; the display will show weight.
3. Depress the HEIGHT button. Console will display a height value in the
chosen format. In inches format, 66.0 will display as shown in Figure 5 with
the left most 6 flashing. Use the and buttons to input the proper height
value for the flashing digit. Press ENTER. Continue for all the digits until
desired height is entered. If operating in feet and inches mode, 5’ 06.0” will
initially display. In kilograms mode, 169.0 cm will initially be displayed.
4. Depressing the ENTER button for the right most digit and the Body Mass
Index value will now display (Fig. 6). A legend below the display explains the
significance of the BMI result.
5. Scale will return to the weight display after a few seconds. Press ON/ZERO to
immediately return to weighing mode.
Note: It is often convenient to attend to the patient immediately after the weighing. The
last measurement may be recalled after the patient steps off the scale and locked on
the display simply by pressing RECALL.(See pg 9)
inch
BMI
inch

9
Using the Tare Function
Note: Only for objects heavier than 1.6 lbs.
1. Turn the scale on and wait for the display to read “0.0”.
2. Place the object(s) on the scale platform. The display will indicate the weight
of the object(s).
3. Depress the TARE button. “0.0” will be displayed on the console.
If the object is removed from the platform, its weight will be displayed as a
negative value.
4. Step on the platform with the object still on it. The weight displayed will be
the person’s net weight.
5. Depress ON/ZERO to return the scale back to normal weighing operation.
Changing Display Units
Your scale can display weight readings in either pounds or kilograms. The unit
of measure can be changed at any time by pressing the LB/KG button. The
current mode of the scale is identified on the bottom of the LCD display.
When powered on, the scale will use the last selected mode. For example, if the
scale turns off when in kilograms mode, it will power on with kilograms as the
unit of measure.
Note: You may disable the LB/KG button so that the scale only will display your selected
unit of measure. (See User Settings section on page 11.)
Using the Recall Function
The scale has the ability to recall and display the last weight measurement
taken.
1. While “0.0” is displayed on the console, depress the RECALL button.
2. The most recent weighing will be displayed along with “PRIOR WT” (Fig. 7);
if last weight was an averaged reading, “AVG WT” will display (Fig. 8).
3. The scale will be locked from further use for 30 seconds or until either of the
following occurs:
a. RECALL is depressed again
b. ON/ZERO is depressed
PRIOR WT
STABLE
lb
Figure 7: Stable prior weight display
PRIOR WT
AVERAGE WT
PRIOR WT
lb
Figure 8: Average prior weight display
PRIOR WT
AVG WT

10
Programming Auto-Off Time
Your scale has been preset at the factory to shut down after one minute of no use.
This can be programmed from 12 seconds to 25 minutes to suit your needs.
1. Depress ON/ZERO and wait for the display to show “0.0”. Do not stand on
platform.
2. Hold MENU button down and depress the RECALL button. “Set-0” will be
displayed along with the up and down arrows; the “0” will be flashing.
3. Depress the button repeatedly until “Set-3” appears, depress ENTER.
4. The Auto-Off time currently programmed in the scale will display as minutes and
tenths of minutes (i.e. “03.2”); the far left digit will be flashing. Use the and
buttons to set the desired value, press ENTER to advance to the next digit. For
example, setting the time to “00.5” will turn the scale off after 30 seconds of no
use; “02.0” will turn the scale off after 2 minutes; “25.0” will turn the scale off
after 25 minutes.
5. Press ENTER when complete to save and return to normal weighing operation.
NOTE: If an AC adapter is used to power the scale, the scale will remain on at all
times and the Auto-Off function is disabled.
Battery Life Indicators
Figure 9: Battery indicators
Programming Time & Date
1.Depress ON/ZERO and wait for the display to show “0.0”. Do not stand on
platform.
2. Hold MENU button down and depress the RECALL button. “Set-0” will be
displayed along with the up and down arrows; the “0” will be flashing.
3. Press once, “Set-1” appears, depress ENTER.
4. Use the , and ENTER buttons to set the time, date and year.
5. Press ENTER when complete to save and return to normal weighing operation.
The scale has excellent battery life with most users getting more than two years
from a single set of batteries. Your battery longevity will vary with the frequency
of use and the length of the Auto-Off timer. To help ensure you are never
without the use of your scale, it comes with a battery life indicator. When the
battery pictorial is empty and the frame is flashing, replace batteries within a
couple weeks (Fig. 9).
NOTE: Properly dispose of old batteries. Install four (4) new alkaline D-cell
batteries. Do not mix new and used batteries.
Indice