BEIER-Electronic SV3-1-8Z Manuale utente

Instruction Manual
Controller
Type: SV3-1-8Z
BEIER-Electronic
Winterbacher Str. 52/4, 73614 Schorndorf - Weiler
Telefon 07181/46232, Telefax 07181/45732

Table of Contents
Table of Contents....................................................................................................... 2
Dangers caused by Electric Power............................................................................. 3
Safety-Technical Indications for the User................................................................... 4
General Description of the Device.............................................................................. 5
Technical Data............................................................................................................ 6
Technical Data............................................................................................................ 7
Technical Data............................................................................................................ 8
Technical Data............................................................................................................ 9
Wiring Diagram......................................................................................................... 11
Technical Description ............................................................................................... 12
Technical Description ............................................................................................... 13
Technical Description ............................................................................................... 14
Electrical Equipment................................................................................................. 17

Dangers caused by Electric Power
Emergency !
In the case of danger caused by electric power,
shut-down the machine immediately by means of
the main switch!
Warning!
Damages on the machine may result therefrom.
Operate the controller only with faultless condition of the electrical
equipment. When damages are recognized: Immediate shut-down of the
controller, switch-off by means of the main switch and have it repaired!
Put controller back to use only, if the faultless condition of the electrical
equipment has been verified by an electrician.
In the case of disturbances in the electrical power supply, the controller must
be switched off immediately!
Only use original fuses with the current intensity specified in the Technical
data sheet!
Connecting cables and leads must be laid so that damages and dangers are
excluded and impossible.
Work on the electrical equipment may only be carried out by electricians or
instructed personnel under the supervision of electricians, according to the
electrical-technical regulations in force.

Safety-Technical Indications for the User
The following indications are for the purpose of personal safety of the operators, as
well as for the safety of the described products and the connected devices.
Non-observance may result in death, serious injuries of the body or damage to
property!
Warning!
Before opening the device
the mains plug must be disconnected.
•Before setting the device into operation the accordance of the mains voltage of
the controller and the feeding device with the local mains voltage must be verified.
•Set and connect plugs, plug link, slide switch according to technical description!
•The set-up is to be carried out by technically qualified personnel!
•Only inductive loads may be connected to the controller!
•Check the electrical equipment of the controller at least once a week for visible
damages and defaults on the outside!
•Detected defaults as well as changes in the operation behavior must be reported
immediately to the person / dept. in charge. Immediate shut-down and securing of
the controller, if required!
•Check the electrical equipment of the controller regularly in accordance with the
respective national regulations.

General Description of the Device
Power Unit
The SV3-1-8Z is a control device for oscillation conveyor drives with electromagnets
and works according to the TRIAC-phase angle control principle for the amplitude
limitation. Three conveying devices can be connected.
Essentially there are two operation modes:
•The full-wave control with 100 oscillations per second at 50 Hz mains
frequency or 120 oscillations per second at 60 Hz mains frequency
•and the half-wave control with 50 oscillations per second at 50 Hz mains
frequency or 60 oscillations per second at 60 Hz mains frequency.
In spite of its very compact construction design the control device SV3-1-8Z covers
the performance range that is usual with vibration feeding devices. As standard finish
the device is equipped with soft start and soft run-out, which can both be adapted at
any time to the connected oscillation conveyor drive.
By means of the external, potential-free control input 10 - 30V AC or DC, the
SV3-1-8Z can be enabled or disabled. This is very favorable in the case of
applications with frequent switching operations (e.g. level control), because the
control device doesn’t have to be switched via the mains voltage.
The set-point adjustment of the conveying performance is done by means of a
potentiometer, which is accessible from the outside.
An electronic current control prevents a possible overload of the control device and
the conveyor system.
Three status LEDs inform at any time about the current state of the SV3-1-8Z.
Within the indicated limit values there is no setting required for the mains voltage and
mains frequency.
Power supply
The SV3-1-8Z disposes of a switch-controlled 24V DC power pack. It is used for the
supply the internal time function elements, the connected proximity switches and the
outputs (blast air, control output). The power pack is short circuit-proof and can
supply current of max. 1,5A.
Time function elements
The integrated time function elements have an extensive logic (see page 12). A total
of 11 times is available enabling the realization of different functions. These times
can be set from 0,0 to 25,0 seconds.

Technical Data
Mains voltage 110 - 230V AC +/-10%
Mains frequency 50 / 60Hz +/-1%
Output voltage AC 50 – 230V
(but max. mains voltage)
Output current per feeding
device min. 0,1A, max. 8,0A
(max. current when mounted onto metal plate)
Cumulative current for all
outputs Max. 10A
Load 25 - 2000 VA. Only inductive loads are allowed to
be connected!
Device fuse 10A melting fuse (5 x 20mm)
Control fuse 1A melting fuse (5 x 20mm)
Electronic over-current
disabling At approx. 13A
(display by orange status – LED)
Soft start 0 - 5 seconds (related to set-point adjustment 10)
Soft run-out 0 - 5 seconds (related to set-point adjustment 10)
Set-point adjustment Potentiometer (position 1 – 10)
Control input 10 - 30V AC or DC (potential-free)
Insulation Voltage Input/Output 0,5kV
Inputs for proximity switches 5 inputs: 10-30V DC
Outputs 3 pnp-outputs: 24V DC, max. 0,5A
1 relay-output: 230V, max. 5A
Time function elements 5 time function elements with adjustable turn-
on/turn-off delay (0,0 – 25,0 seconds)
Ambient temperature 0 - 40°C
Dimensions Aluminum housing 260 x 160 x 90mm
Type of protection IP54
Adhesive label inside the controller
Ext. Start/Stop
4
3
X11
10-30V AC/DC
S11/6
ON
OFF
inv.
n. inv.
Inductive load only !
4
3
1
X21, X22, X23
+24V
_
Signal
F1
1A MT F2
10A MT
PE
PE
3
1N
L1
X0 OFF
R17
ON
R17
OFF
R11
ON
R11
OFF
R23
ON
R23
PE N
PE
3
2
1
X1, X2, X3
PE 41 42 43-
X51
0V
PE
K51
max. AC230V / 5A
38
X50
27 28 29 30
X31
DC 24V max. 0,5A
X50
Out
_
X32
Out
_
13 14 15 17 18 19
+24V
Signal
+24V
Signal
_
X41 X42
X50
_
23 24 25 26
X12
X50
Out _
DC 24V max. 0,5A

GB Controller SV3-1-8Z
GB_Steuergerät SV3-1-8Z.DOC 0710 BEIER-Electronic 7
Typ SV3-1-8Z
AC
110-230V
50/60Hz
max. 8A
X1
X2
X0 X31 X32
X11 X41 X42
X1 X2
X21 X22 X12
X3
X3
X23
Q1
R1
H1
R2
H2
R3
H3
Technical Data

GB Controller SV3-1-8Z
GB_Steuergerät SV3-1-8Z.DOC 0710 BEIER-Electronic 8
Technical Data

GB Controller SV3-1-8Z
GB_Steuergerät SV3-1-8Z.DOC 0710 BEIER-Electronic 9
Technical Data
X0 Connection for mains voltage.
X1 Connection for feeding device 1
X2 Connection for feeding device 2
X3 Connection for feeding device 3
X11 Connection for external control input
X12 Connection for control output
X21 Connection for proximity switch
X22 Connection for proximity switch
X23 Connection for proximity switch
X31 Connector for blast air valve 1
X32 Connector for blast air valve 2
X41 Connection for proximity switch
X42 Connection for proximity switch
X50 Connection for inputs, outputs and time function elements
X51 Bridge -/PE, relay contacts K51
Q1 Main switch
R1 Set-point potentiometer (X1)
R2 Set-point potentiometer (X2)
R3 Set-point potentiometer (X3)
Umax1 Limitation of the maximum output voltage (X1)
Umax2 Limitation of the maximum output voltage (X2)
Umax3 Limitation of the maximum output voltage (X3)
H1 Status – LED (X1)
H2 Status – LED (X2)
H3 Status – LED (X3)
H11 LED for control input
H13 7-segment display for setting of the times
H14 Run-LED (flashing: time function elements IO)
S1 Changeover contact between full- and half-wave operation (X1)
S2 Add-on connection of the additional load at small feeding devices <ca. 40VA
(X1)
S3 Changeover contact between full- and half-wave operation (X2)
S4 Add-on connection of the additional load at small feeding devices <ca. 40VA
(X2)
S5 Changeover contact between full- and half-wave operation (X3)
S6 Add-on connection of the additional load at small feeding devices <ca. 40VA
(X3)
S11 DIP-switch for time function elements
S12 DIP-switch for time function elements
S13 Selector switch for times selection (H13)
S15 DIP-switch for X1
S16 DIP-switch for X2
S17 DIP-switch for X3

GB Controller SV3-1-8Z
GB_Steuergerät SV3-1-8Z.DOC 0710 BEIER-Electronic 10
F1 Melting fuse 1A
F2 Melting fuse 10A
T1/1 Setting for soft start (X1)
T1/2 Setting for soft run-out (X1)
T2/1 Setting for soft start (X2)
T2/2 Setting for soft run-out (X2)
T3/1 Setting for soft start (X3)
T3/2 Setting for soft run-out (X3)
T41 Time function element
T42 Time function element
T43 Time function element
T44 Time function element
T45 Time function element
T46 Tracking delay for outputs (after shut off of the control input)
Indice
Altri manuali BEIER-Electronic Controllori

BEIER-Electronic
BEIER-Electronic UFR-1230 Manuale utente

BEIER-Electronic
BEIER-Electronic SFR-1-HL Manuale utente

BEIER-Electronic
BEIER-Electronic SV1-2-10Z Manuale utente

BEIER-Electronic
BEIER-Electronic UFR-1230-D Manuale utente

BEIER-Electronic
BEIER-Electronic SFR-1-D Manuale utente

BEIER-Electronic
BEIER-Electronic SFR-1 Manuale utente