BeSense Z-Wave
Command Class Specification
When the door sensor is opened or recovered, it will send “Binary Sensor Report” and
“Notification Report” commands to the device under Lifeline group.!
When door sensor is opened:!
Sensor Binary Report, Value = 0xFF, Type = 0x0C
Notification Report, Notification Type = 0x07, Event = 0x08 When door sensor is recovered:
Sensor Binary Report, Value = 0x00,Type = 0x0C Notification Report, Notification Type = 0x06,
Event = 0x16
When tamper switch is triggered or recovered, the door sensor will send “Sensor Binary Report”
and “Notification Report” command to the device under Lifelinegroup.!
Tamper Triggered:!
Sensor Binary Report, Value = 0xFF,Type = 0x08
Notification Report, Notification Type = 0x07, Event = 0x00 Tamper recover (press tamper
switch for 0.5s):!
Sensor Binary Report, Value = 0x00, Type = 0x08 Notification Report, Notification Type = 0x07,
Event = 0x00
Association Group2
If there is any device under Association Group2, the door sensor will send “BASIC SET”
command to control those devices when the door sensor is triggered. For example: when the door
sensor is triggered, it sends adjustable parameter “BASIC SET” command to a lamp under
Group2, you can adjust the lamp’s luminance through the parameters of this command; if the set
light-up time out (see the Configuration Description), the sensor will send “BASIC
SET”command to turn-off the lamp.
When sensor is triggered:!
[Command Class BasicBasic Set,Value = 0xFF(default 0xFF, configurable, see the
Configuration Description)] When light-up time out:!
[Command Class BasicBasic Set,Value = 0x00]
Configuration Description
a) “Basic Set” configuration!
If there is any device under Association Group2, the door sensor will send “Basic Set = value”