Bewator PD30EM Manuale di istruzioni

PD30EM & PD40EM
Installation & User Manual
DE FREN SV

Book contents
English ............................................... 3
Svenska.............................................17
Deutsch .............................................31
Français.............................................45

PD30EM & PD40EM Installation and User manual 3
ENG
English
Copyright © 2006 Bewator AB, Solna.
Material from this manual may only be copied with the consent in writing of Bewator.
Bewator reserves the right to alter both the content of the manual and the design of the
product.
Document number: 81618-9
Bewator AB develops and markets a complete security product range that includes access
control, intruder alarm and video control. Sales, installation and servicing are handled by
an International national dealer network.
Actions (such as unauthorised editing manipulation, copying etc.) must not be taken
with the software contained in the products and systems. Such actions are regarded as
copyright violation and may result in imprisonment or fines and may likewise lead to an
obligation to pay damages and compensation for using the software.

4 PD30EM & PD40EM Installation and User manual
ENG
Contents
About this manual...............................................................5
ProxCodoor - General..........................................................5
Supplied material........................................................... 6
Addressing .................................................................... 6
PD30EM installation............................................................7
Recommended lock cases for the PD30EM .................... 10
PD40EM installation ......................................................... 11
Recommended lock cases for the PD40EM .....................14
Technical data................................................................... 15
Using the ProxCodoor ....................................................... 15

PD30EM & PD40EM Installation and User manual 5
ENG
About this manual
This manual covers both the Scandinavian style (PD30EM) and the
International style (PD40EM) of the ProxCodoor. In the scope of this
manual we will use the name ProxCodoor (unless notified.)
ProxCodoor - General
The ProxCodoor is a system component in the Bewator Entro Access
Control system range of products. It could be used indoors in general
(sales floor, shops, restaurants, manufacturing and assembly areas,
entrance and storage rooms). ProxCodoor is based on the popular
Codoor electromechanical codelock, but instead of a keypad it includes
a proximity reader which reads tags/cards of type EM4102. It is powered
from the system and connects (via a dropbox) to the local bus in Bewator
Entro and communicates with a Segment Controller.
The ProxCodoor is suitable for most doors with handle-operated
mortice locks. Check suitability by simply measuring your own lock. (See
further on the recommendations for each model).
It then requires only that the supplied 4-wire cable is mounted from
the dropbox through the door to the lockcase.
1 %3#
1
11:30
The illustration shows the PD30EM - but the PD40EM is mounted in a
similar way.

6 PD30EM & PD40EM Installation and User manual
ENG
Supplied material
The ProxCodoor kit consists of the following parts:
The ProxCodoor unit with integrated proximity reader and 20 cm
cable (with connector matching the long cable).
Dropbox for connection to Entro.
5 metre cable with a 4-pin connector and a free end to be connected
to the dropbox.
Extension sleeves for handle nipples (use only one pair).
1 reinforcing spring.
1 reinforcing spring holder.
Additionally you need some kind of door loop to feed the cable from the
door to the dropbox.
NOTE! No batteries should be mounted in the unit (although there are
cutouts in the back).
Addressing
Before finally mounting the unit the address must be set between 1 - 32.
This is recommended to be done without power (unless the software
might not recognise any change). There are a two rotary switches at the
back of the unit where the arrows indicates the selected digits. If you
have the address switches upwards it looks like the figure.
The address is conformed of two digits:
1st digit (left): 0 - 3
2nd digit (right): 0 - 9
This will correspond to the address ranges used in the Entro system.
•
•
•
•
•
•
•
•

PD30EM & PD40EM Installation and User manual 7
ENG
PD30EM installation
Remove the cylinder ring and the door handle from the door by
loosening the four screws. See photo .
The lever handle spindle should project no more than 20 mm on the
outside of the door. If the spindle is too long, push it through into
the handle on the inside. If this cannot be done, cut the spindle to
the right length. See photo .
Screw the supplied extension sleeves to the nipples for the handle.
Use the appropriate size sleeve to suite the bolts supplied with the
handles. Note! If neccessary, this must be mounted on the opposite
side of ProxCodoor (inside) See photo .
1.
2.
3.

8 PD30EM & PD40EM Installation and User manual
ENG
Disassemble the lockcase from the door and cutout enough space
for the cable entry at the bottom of the hole inside the handle. Also
be sure there is space to finally feed the cable connector (and some
remaining cable) beneath the lockcase. See figure .
!
PD30EM
Figure
Install the cable from the lockcase to the door loop and further to
the place for the dropbox. You may have to drill a hole through the
door between the lockcase and the door loop.
Mount the dropbox somewhere above the door, less than 5 metres
from the lockcase and connect the 4-wire cable according to the
following table.
Colour on cable Drop box (PL2)
Signal Alt. 1 Alt. 2 *)
V+ Pair 1 Red Green 1
0V Black Black 2
Com B Pair 2 White White 3
Com A Green Black 4
Screen - - 5
*) May exist in older versions.
4.
5.
6.

PD30EM & PD40EM Installation and User manual 9
ENG
Put the connectors in the PD30EM together and place them in the
space beneath the lockcase. Be sure that the guides are matching
each other. See figure .
Push the lockcase back in final position. (Possibly wait to tighten it
until the system is tested).
Place the PD30EM on the outside of the door with the handle
attached, and pass the lever handle spindle through the square
hole. See photo .
Note! The red mark on the follower should always point downwards.
Feed the cable to the space at the outer side of the lockcase.
Tighten, not too hard, the four previously loosened screws (the
screws for the handle first). See photo .
Log on an authorised card (or tag) in Entro and test it on PD30EM.
You can that see that the unit operates correctly by seeing the yellow
LED (on the front) flashing, until five readings are performed. The
LED will then go off.
Ready!
RED
7.
8.
9.
10.
11.
12.

10 PD30EM & PD40EM Installation and User manual
ENG
Recommended lock cases for the PD30EM
PD30EM is suitable for most doors with handle-operated mortice locks.
Check suitability by simply measuring your the distance between the
center of the handle follower and the center of the cylinder. The backset
should normally be 70 mm.
The PD30EM can be used with many types of locks, like e g ASSA 8761
or 765 etc. If in doubt please check with your local locksmith.
5 -
116 mm
01
8x8 mm
8
3
-
0
3
"ACKSETMM
Basic needs are the following:
The distance between the centre of the handle and the centre of the
cylinder should be between 105 – 116 mm.
Latchbolt function.
The handle must have an 8 mm square spindle.
The handles fixing holes 30-38 mm (diagonal).
NOTE! PD30EM is only for internal fitting and operation and should
neither be specified for back to back installation.
•
•
•
•
Questo manuale è adatto per i seguenti modelli
1
Indice
Lingue:
Altri manuali Bewator Serratura