BFT CELLPRIM4GE Manuale utente

P a g e | 1
Dealer Manual
DO NOT GIVE TO HOME OWNER.
FOR PROFESSIONAL USE ONLY .
Cellular Intercom System
Note: For legal reasons, telephone technical support is for registered and
qualified product dealers only. Home owners and end-users should contact their
dealer for product technical support.
Preferred!

P a g e | 2
Contents
Really Important things (site survey)
…………….Pg 3
Overview of outside of product
…………….Pg 4
Overview of Inside
…………….Pg 5
Pedestal Installation
…………….Pg 6
Wall mount installation
…………….Pg 7
Power IN module
…………….Pg 7
Cellular module in detail
…………….Pg 8
Wiring relays
…………….Pg 8
Keypad / Prox module in detail
…………….Pg 9
Connecting slave devices
…………….Pg 9
Inserting SIM
…………….Pg 10
Powering up and LEDs
…………….Pg 10
Installing the Programming APP
…………….Pg 11
Begin Programming a New Install
…………….Pg 12
Begin Programming Existing Install
…………….Pg 12
Programming
Check Reception
…………….Pg 13
Activate clock sync
…………….Pg 14
Activate daily activity
…………….Pg 14
Program dial out and dial in numbers
…………….Pg 15
Volumes
…………….Pg 17
Dialling & Talk Times
…………….Pg 17
Service Calls
…………….Pg 18
Info Screen
…..…….Pg 18
Pass Codes
…………….Pg 20
Relay Times
…………….Pg 20
Notifications
…………….Pg 21
Keypad Programming
…………….Pg 21
Automatic Triggering Times
…………….Pg 24
Client List on iphone
…………….Pg 24
Client list on Android
…………….Pg 25
Do Not Disturb
…………….Pg 25
After Hours
…………….Pg 26
PROX card Programming
…………….Pg 26
Complete List of Parameters
…………….Pg 29
Control by SMS
…………….Pg 31
Troubleshooting
…………….Pg 31

P a g e | 3
Really Important things you Need to Know..
Please read this entire manual before installing
this product.
To be installed by certified and qualified
personnel / gate automation dealer only. Not
for DIY install!
Ensure there is good At&T or T-Mobile 4G
signal at the gate/door of the install site
BEFORE installing this product. (This unit will
also fall back to 3G service in some locations
depending on network).
Set up on a bench in workshop BEFORE going
to site. Program the unit in the comfort of your
work bench and call technical support should
you have questions.
This product requires a SIM card from either
At&T or T-Mobile, however T-Mobile may not
have matching band coverage in your area!
The SIM should be a voice and text plan.
Do not use a DATA only SIM.
Ensure your SIM has VOLTE (HD Voice calling
service is enabled).
Manufacturer warranty does NOT cover lighting
/ storm damage. You MUST fit external surge
protection and lightning rod in order to maintain
warranty on this product.
Evidence of surge protection will be requested
on generation of RGA numbers.
5
Preferred!
1
2
3
4
6

P a g e | 4
Now lets have a look around the product…
Call button
Speaker grill
Hinged front door
Optional Keypad
Architectural
Wall Mount
Traditional Hooded
Wall Mount
Security Screw Access
(Open top screws only)
Hinged front door
Microphone
Built in antenna
Security access
key
Pedestal
Mount
Version
Optional Keypad
Optional Prox
Reader
Optional Prox badge reader
Call Button

P a g e | 5
Overview of Inside…
Push button
Optional
Keypad
module
Antenna
Connection
Optional
Prox reader
module
Optional
Prox Coil
Cable Entry
Hole
Mounting
Holes
Wall
Mount
Version
Cellular
Module
Lock
Push button
Cellular
PCB
Optional
Prox Coil
Optional
Keypad
module
Optional
Prox reader
module
Surge &
Power
Conditioning
Module
Pedestal
Mount
Version

P a g e | 6
Pedestal Installation
!
!
After fitting the box to the gooseneck,
re-fit the module and connect a 14
gauge earth wire to the earth terminal.
3
Earth Rod
(close as
possible)
Maintain manufacturer’s
warranty by adhering to the
guidelines shown. Use 110v
surge protected supply.
Surge protected 110v
4
24v dc PSU
16 gauge MIN
1
25 feet MAX
Call box
2
Remove 4 screws
and remove power
conditioning module
(if needed)
Use minimum 16 gauge wire
from the 24v dc adaptor provided
to the terminals shown. 12v
installs should use SOLAR
input terminals.

P a g e | 7
Wall Mount Installation
!
!
Earth Rod
24v DC
OUT
24v DC IN from PSU
To Earth Rod
Weatherproof
enclosure
Use 110V surge
protection to maintain
warranty
Wall or Pillar
(side view)
IMPORTANT
18 gauge MIN
10 feet MAX
Wall mount
call station
-
+
+
-
+
-
1A quick blow input fuse
Power
Module in
Detail…
+
-
Earth Rod MUST be
connected for warranty
Power out
Solar Panel IN
24vdc IN (do not use 12v here)
12v DC IN or 12v
Battery HERE

P a g e | 8
Relay 2
Note: The manufacturer is
not responsible for wiring to
third party devices. Please
consult an experienced
security installer.
Pedestrian
gates or door
Magnetic
lock
Exit button
Separate lock Power
supply (not supplied)
Wiring
Relays
Start
Common
Gate Position
Limit switch
(optional)
Electric Gates
Exit Button
To Call
Button
12v dc 100mA
(backlighting)
24v dc IN
(pre-wired)
Relay 1
CPU Status
Signal Status
Power
Cellular
Module in
Detail…
SIM holder
Modem Status
Antenna
connection
N/O
COM
N/C
N/O
COM
N/C

P a g e | 9
1 2 3 24v OUT
IN
OUT
IN OUT
IN
1 2 3 24v OUT
IN
1 2 3 24v
1 2 3 24v
Keypad /
PROX
Modules
in
Detail…
1
2
Slave OUT connections
3
24v out
GND
Slave IN connections
Slave IN
Slave OUT
Optional
PROX
module
Baud jumper (remove
for older intercoms)
Keypad
Module
To next
device
Optional
Keypad
Optional
Prox reader
Optional Slave
Keypad
Optional Slave
Prox Reader
CAT5 (30ft max)
300ft if device powered
separately
To next
device
Connecting
Slave
Devices

P a g e | 10
Inserting the SIM card
Powering Up & LEDs
Perform a final check of wiring and ensure the antenna is connected before switching on the
power. Once the power is switched on, the power LED should illuminate.
CPU
Flashing = standby
Constant ON/OFF = busy
SIGNAL STRENGTH
1 flash = poor (1 bar)
2 flashes = low (2 bars)
3 flashes = good (3 bars)
4 flashes = Strong (4 bars)
5 flashes = searching
POWER
MODEM
Flashing = standby
Constant ON/OFF = searching
WARNING
Ensure power is OFF. Do not hot
insert or remove while power on.
NANO SIM
45 chamfer IN, pads DOWN
Ensure SIM is activated.
Pre-pay SIM will need credit first.
Indice
Altri manuali BFT Sistema di interfono