Biamp Apprimo Touch 8i Istruzioni operative

A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
PRODUCT DESCRIPTION
The Apprimo Touch 8i is an 8" control panel for any room
that requires a more complex level of control, while still
being a stylish and discreet interface that fits in any type of
interior design.
Apprimo
Touch 8i Control Panel
Installation and Operation Guide
shown on the attached Table Mount
CONTENTS
Touch 8 control panel with attached Table Mount
FEATURES
• 8" capacitive touch LCD interface
• Scratch-resistant glass
• Display brightness can adjust automatically to the
ambient light level
• Customizable user interface to fit customers’ control
requirements and corporate identity
• PoE powered (IEEE 802.3at Class 3, 15W) for simple,
single CAT5e/CAT6 cable installation
Apprimo Touch 8i
(with table mount attached)
Reset Pin
3 m (10 ft) Cat5 cable
Reset Pin Cat5 Cable

page 2 Installation and Operation Guide Apprimo Touch 8
3
PRODUCT INSTALLATION
Table Installation
1. Remove cover from the bottom of the table mount.
2. Insert network cable into port on the back of the
control panel.
3. Reattach the cover routing the cable through the
notch in the latch and stand.
4. Follow on-screen prompts to complete the installation.
21
4
5

Apprimo Touch 8 Installation and Operation Guide page 3
OPERATION
Device Reboot Settings
A simple touch will wake up the control panel. It provides a
method of interacting with or controlling the room system.
The initial interface and on-screen prompts make use of the
control panel default setup.
Note: More options can be enabled upon setup, including user
proximity to "wake up" the panel.
MAINTENANCE
Cleaning: Use a soft cloth (microfiber recommended)
to clean the glass and cabinet. Do not use abrasives or
solvent-based cleaning products. If necessary, use a
specially formulated screen cleaner on a soft cloth to wipe
any smears off the control panel. Wipe with a dry cloth to
remove any residual moisture.
Settings: Insert reset pin into the designated hole in the
top of the control panel rear. A simple press will bring up
the device settings screen.
Note: Inserting the pin in the other hole will initiate a device
reboot.
SOFTWARE LINKS
Additonal option to congure user interface on the Apprimo 8i
Project Designer: Available by request here

page 4 Installation and Operation Guide Apprimo Touch 8
ACCESSORIES (OPTIONAL)
Concrete Wall Mount Low Prole - custom back box
Angled Wall Mount * Flat Wall Mount *
Model Name Description Mounting Type**
Apprimo 8-WMA Angled wall mount bracket To drywall or gang box
Apprimo 8-WMF Flat wall mount bracket To drywall or gang box
Apprimo 8-WMC Concrete (surface) wall mount To a solid surface wall
Apprimo 8-WML Low profile wall mount bracket For drywall / sheet rock
* Shown connected to a single gang box (US). Mounting base plate will accept
most gang box types.
** Anchoring / mounting hardware and gang boxes are not included and must be
appropriate for the surface and conform to local building codes
It is necessary to remove the Table Mount from the control panel in order to
mount the panel to any of the accessory wall mounting options. The instructions
to remove the table mount are on the next page. Do this before proceeding with
the accessory mount instructions. Clicking the links in the table below will take
you to the chosen instructions.

Apprimo Touch 8 Installation and Operation Guide page 5
ACCESSORIES (OPTIONAL)
165 cm
(65")
122 cm
(48")
102 cm
(40")
2 3
4
1
Determine placement on the wall
1. The center of the control panel would typically be
located between 102 – 165 cm (40" – 65") above the
nished oor. Route Cat 5e/6 cable to the location.
There are channels and/or knockouts on the base
plates for cable routing if installing on a solid wall.
The Low Prole mounting option is designed work
with network cabling inside the wall space.
Note: Follow local guidelines for accessible wall controls.
Installations complying with US ADA guidelines the top of
the panel should not exceed 122 cm (48") from the oor.
Remove table mount from the control panel
2. Remove cover from the rear of the table mount.
3. Remove screw holding table mount to control panel.
4. Remove mount by sliding it down and then lifting up.

page 6 Installation and Operation Guide Apprimo Touch 8
1
2 2
3 3
ACCESSORIES (OPTIONAL)
abab
Flat Wall Mount
(Apprimo Touch 8-WMF)
Angled Wall Mount
(Apprimo Touch 8-WMA)
70 mm
(2.75")
140 mm
(5.5")
Installation - Flat or Angled Wall Mount
The control panel can be mounted to a wall with or without a gang box. Most
gang box styles are supported.
1. Attach wall plate directly to the wall with screw anchors or screw it to a
gang box (most gang box styles are supported). Orient the plate with the
arrows pointing up.
Both Flat and Angle wall mounting options are shown below. The Angle Mount
has a notch to route the cable through if mounted on a solid wall.
2. Attach wall mount base to control panel - t clips in control panel back (a),
and slide up (b).
3. Secure base with a screw.
1

Apprimo Touch 8 Installation and Operation Guide page 7
4
5
ACCESSORIES (OPTIONAL)
Center tab latched
Center tab latched
Flat Wall Mount
4
5
Angled Wall Mount
Installation - Flat or Angled Wall Mount (continued)
4. Insert network cable into port on the back of the control panel.
5. Mount the panel on the wall plate by hanging it on the top tabs then rotating
in and clipping into the bottom tab. Ensure the tab is fully engaged (see
circled views).

page 8 Installation and Operation Guide Apprimo Touch 8
Installation - Concrete Wall Mount (Apprimo Touch 8-WMC)
1. Securely attach wall plate directly to the wall with concrete anchors (or
construction adhesive). Orient the plate with the arrows pointing up.
2. Attach wall mount base to control panel - t clips in control panel back (a),
and slide up (b).
3. Secure base with a screw.
4. Insert cable plug in the jack and route cable down or up. An opening is
available if the cable is routed down (a). There is a small knockout at the top
of the mount that should be removed (b) to route the cable up.
5. Mount the panel on the wall plate by hanging it on the top tabs then rotating
in and clipping into the bottom tab. Ensure the tab is fully engaged in the
base's slot.
a
a
b
b
23
4
1
5
ACCESSORIES (OPTIONAL)

Apprimo Touch 8 Installation and Operation Guide page 9
ACCESSORIES (OPTIONAL)
Installation - Low Prole Mount Bracket (Apprimo Touch 8-WML)
Network cabling must be routed to the desired panel location.
1. Cut a rectangular hole in the wall (drywall or sheet rock).
Dimensions H x W: 90 x 122 mm (3.5 x 4.8")
Note:The hole must have clearance of 25mm (1") on either side of the hole to
accommodate the full clamp rotation.
2. Insert the bracket into the hole.
3. Screw the clamps down to secure the plate in the wall.
4. Attach baseplate to control panel - t clips in control panel back (a), slide
up (b), and secure with screw (c).
ac
b
90 mm
(3.5")
122 mm (4.8")
23
4
1

A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
14MAR2023
CONTACT US
Email: [email protected]
Web: support.biamp.com
Warranty: biamp.com/legal/warranty-information
Safety & Compliance: biamp.com/compliance
LOW PROFILE MOUNT BRACKET (CONTINUED)
Installation (continued)
5. Plug network cable in the back of the control panel and feed excess wire
into the wall.
6. Position the panel's backplate aligned with, and against all four magnets in
the low prole bracket. The panel will be held securely on the wall.
5
6
Altri manuali per Apprimo Touch 8i
2
Indice
Altri manuali Biamp Pannello di controllo

Biamp
Biamp Vocia WR-1 Manuale utente

Biamp
Biamp Apprimo Touch 8i Istruzioni operative

Biamp
Biamp TEC-X 2000 Istruzioni operative originali

Biamp
Biamp TEC-X 1000 Istruzioni operative originali

Biamp
Biamp RP-S4 Manuale utente

Biamp
Biamp IMPERA SIERRA II Manuale utente

Biamp
Biamp Apprimo Touch 8i Manuale utente