BigDog PR-R13PI Manuale utente

1
PR-R13PI
12+
1
OUTLET
INTELLIGENT RACK MOUNT
POWER DISTRIBUTION UNIT

2
Introduction
Thank you for purchasing the PR-R13PI.
Your new Power Distribution Unit (PDU)
by Big Dog Power provides ltered AC
power to your equipment. 12 individually
controlled outlets provide up to 5100
Joules of surge Protection. Wi-Fi and Wired
LAN connections allow for exibility with
placement and network connectivity. The
built in Self-Healing functions of the
PR-R13PI will keep your network connected
equipment going by automatically resetting
the power going to the outlet.

3
Features
• 12 individually controlled outlets
• 1 always on Front outlet
• Rack Mountable 2U
• Self-Healing functions for network
connected equipment
• Surge Mileage: Track when a Surge Event happens and the
remaining health of the surge protection
• Replaceable Surge modules
• 2040 and 3060 Joule surge protection
• Temperature monitoring with 4 thermostats
• Web and Mobile app for remote management and notication
• I/O for additional integrations
• RS-232/Serial and IP automation integration
• Grounding Lug
• 120V/12A Rating
SMART OUTLETS
+1 ALWAYS ON
REPLACEABLE M.O.V.
SURGE MODULES
POWER METERING
INDIVIDUAL OUTLETS
MAVBASE APP
MANAGEMENT
SELF HEALING
AUTO REBOOT
4 SMART
THERMISTORS
12
FLEXIBLE MOUNTING
OPTIONS
CONNECTED EQUIPMENT
GUARANTEE
WIRED/WIRELESS
CONNECTIVITY
SET MULTIPLE
SCHEDULES

CONTRACTS); LOSS OF THE USE OF MONEY;
LOSS OF ANTICIPATED SAVINGS; LOSS OF
BUSINESS; LOSS OF OPPORTUNITY; LOSS
OF GOODWILL; LOSS OF REPUTATION;
LOSS OF, DAMAGE TO, COMPROMISE OR
CORRUPTION OF DATA; OR ANY INDIRECT
OR CONSEQUENTIAL LOSS OR DAMAGE
HOWSOEVER CAUSED INCLUDING THE
REPLACEMENT OF EQUIPMENT AND
PROPERTY, ANY COSTS OF RECOVERING,
PROGRAMMING, OR REPRODUCING ANY
PROGRAM OR DATA STORED IN OR USED
WITH THE PRODUCT. FURTHER, TO THE
MAXIMUM EXTENT ALLOWED BY
APPLICABLE LAW, Ethereal Home Theatre,
LLC HEREBY EXPLICITLY DISCLAIMS ANY
WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
THESE LIMITATIONS SHALL NOT APPLY TO
ANY DEATH OR PERSONAL INJURY CLAIMS,
OR ANY LIABILITY FOR INTENTIONAL ACTS
OR ACTS OF GROSS NEGLIGENCE
Valid in the United States and Canada
THIS WARRANTY DEFINES ETHEREAL
HOME THEATRE. LLC’S LIABILITY FOR ANY
AND ALL DAMAGES RESULTING FROM THE
OPERATION OR FAILURE OF THE PRODUCT.
THE WARRANTY PROVIDED IS IN LIEU
OF ANY AND ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED. TO THE MAXIMUM
EXTENT PERMITTED BY APPLICABLE
LAW, METRA DISCLAIMS ANY AND ALL
OTHER WARRANTIES WHETHER EXPRESS
OR IMPLIED. TO THE MAXIMUM EXTENT
PERMITTED BY APPLICABLE LAW, ETHEREAL
HOME THEATRE. LLC HEREBY DISCLAIMS
ANY AND ALL LIABILITY FOR DIRECT,
SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING FROM ANY PRODUCT
FAILURE, ANY BREACH OF WARRANTY OR
CONDITION, OR UNDER ANY OTHER LEGAL
THEORY, INCLUDING BUT NOT LIMITED TO
LOSS OF USE; LOSS OF REVENUE; LOSS
OF ACTUAL OR ANTICIPATED PROFITS
(INCLUDING LOSS OF PROFITS ON
Big Dog Power™
by Metra Home Theatre, LLC Limited Product Warranty
and Connected Equipment Limited Warranty
4

5
Limited Product Warranty:
Ethereal Home Theatre, LLC warrants this
product to be free of material defects for a
period of: (1) 5 years for the PR-R13PI, PR-
V7PI and PR-W3PI products, (2) 3 years for
the PR-S1PI product, (3) PR-RMS1 and PR-
RMS2, replaceable surge modules carry a 90
Day warranty from manufacturing defects and
(4) 3 years for any other product subject to
this Warranty (referred to as the applicable
“warranty period”). If the product fails during
the warranty period, Ethereal Home Theatre,
LLC will, at its option: (1) Repair the product
in a reasonable time period, (2) Replace the
product with the same model (or a successor
model with the same or substantially similar
features), or (3) Refund the purchase price.
This Warranty applies only to an original
purchaser of the product who provides proof
of purchase at the time a claim is made.
Conditions and Limitations:
Proof of purchase is required.
Damage caused by accidents, abuse, misuse
or modication of the surge suppressor will
render this warranty null and void.
Transient Voltage Surge Suppression devices
using MOV (Metal Oxide Varistor) technology
are designed to sacrice themselves to
protect the connected equipment. The proper
functioning of this surge suppressor during a
catastrophic surge event like lightning may
result in the depletion of the unit’s protection
capabilities. This is not a defect in design,
material, or workmanship.
Excluded Items:
This warranty does not apply to: (1)
consumable items, such as a replaceable surge
protection module, (2) cosmetic damage such
as scratches, dents, broken plastic parts, and
discoloration (unless same is the result of a
defect in materials or
workmanship), (3) damage resulting from the
failure of another product, (4) damage caused
by misuse or abuse, or (5) damage caused by
unauthorized service of the product.

6
Connected Equipment Limited Warranty:
This is a limited warranty, subject to the
conditions, limitations and exclusions
identied herein. Ethereal Home Theatre,
LLC warrants to the original purchaser of this
surge suppressor that it will at its option, pay
the fair market value of, repair, or replace,
any home entertainment equipment which is
damaged by a transient surge while properly
connected through the Ethereal Home Theatre,
LLC surge suppressor to a properly wired and
grounded AC power line. The Ethereal Home
Theatre, LLC surge suppressor must have been
designed for the particular application.
For additional warranty information including
Connected Equipment coverage and process
visit us at metraav.com
PR-R13PI

7
Anatomy
A. Configurable Power Button
B. LCD Display
C. Display Navigation Buttons
D. Replaceable Surge Modules
S1 – 2040 Joule Rating
S2 – 3060 Joule Rating
E. USB Power Supply
2.4 amp 5v
F. At a glance status LEDs
See LED functions for more information
G. Always On Service Outlet
H. 12 Individually controlled Outlets
I. Grounding pin
J. 15-amp Circuit Breaker
K. Ethernet Port
L. Wi-Fi Antenna
M. Outlet Status LEDs
See LED functions for more information
N. IEC Power Input 120v
O. Thermistor Inputs
P. UPS Link
For Future Use
Q. I/O
1x Contact Sensor Input
1x Relay Output
R. Surface Mount Location for Rack Ears
S. 2U Rack Ears
EN O QP
A
R
I
H
M
K LJ
ES
B
C
G
D

8
LED Indicators
“G” or Ground ON: PDU is grounded properly
OFF: PDU is not grounded
“P” or Power BLUE: Good / Protected and Clean power
RED: Bad / No Protection
“N” or Network BLINKING RED: No Network Connection
SOLID BLUE: Good Network Connection
RAPID BLINKING RED: PDU failure requires reboot or reset
Outlet Status ON: Outlet is On
OFF: Outlet is Off
Voltage SOLID BLUE: Normal / Good Voltage
SOLID RED: Over / Under Voltage
Always On ON: Outlet is On
OFF: Outlet is Off
Surge Module
S1 and S2 LED
ON: Good / Protected
OFF: Bad / Not Protected

9
Installation
Rack Mount
1. Use the included screws to attach the Rack Mount ears to
the PDU near the face of the PDU
2. Slide the PDU into the rack where you intend to mount it
3. Secure the PDU using the appropriate screws for your rack
Installation
Surface Mount
1. Use the included screws to attach the included Rack Mount ears to PDU at the
secondary location
You can find the secondary mount holes halfway towards the
back of the PDU
2. Install appropriate surface mount screws (not included) through the Rack
Mount ears into the desired surface
Step 1
Step 1
Step 2
Step 3
Step 2

10
Installation
Shelf Mount
1. Remove the protective film over the adhesive on the included Rubber Feet
2. Apply the Rubber feet to the bottom of the PDU
3. Slide the PDU onto shelf
4. Place PDU on Shelf
Connections and Use
Physical Connections
1. Screw in the Wi-Fi Antenna
2. Plug in all to be used connections Including:
Ethernet LAN (Skip the Ethernet cable if you will be using Wi-Fi)
Connected equipment power cables
3. Insert the female end of the included 6ft power cord into the PR-R13PI
4. Plug in the Male end of the included 6ft power cord into the main outlet
on your wall
Wi-Fi Setup
If using the Wi-Fi connection, follow these
instructions
1. Plug in the included power cable to the PDU and to the
AC main outlet on the wall. Wait approximately 15-30 seconds,
the power button will begin to flash
2. Scan for Wi-Fi on your Wi-Fi enabled device with a web browser
3. Connect to the Wi-Fi SSID of the PDU
The SSID of the PDU will be “Metra-xxxxxxxxxxxx” where the “x” are the MAC
address or device ID of the PDU. Verify the code of the SSID matches the MAC
address of the PDU with the sticker that is attached to the bottom of the PDU
4. In a web browser go to “192.168.4.1”
5. Go to “Network”
6. Click “SCAN NETWORKS”
The network mode can also be changed before scanning. For ease of setup
we’ll use the default DHCP settings.
7. Select the desired network SSID
NOTE: the PDU requires a 2.4Ghz Wi-Fi connection.
Step 1
Step 3
Step 2
Step 4
Altri manuali per PR-R13PI
1
Indice
Altri manuali BigDog Unità di distribuzione dell'energia