BION COMA Manuale utente

coma l
RGB | RGBW
USER MANUAL
BEDIENUNGSANLEITUNG
www.biontechnologies.com

coma l
RGB | RGBW
USER MANUAL
Safety Instructions
Devices must be installed by qualified personnel in compliance
with all pertaining regulations.
Always refer to the technical parameters in the data sheet. All items are subject to technical modification.
Refer to the attached User Manual as a basis for correct use.
Consult circuit diagram for correct wiring.
Note! Before attempting any work, make sure device is separated from main power.
Make sure protection against line voltage shock is provided during installation.
We recommend securing the installation by RCD circuit breakers.
Note that adjacent parts or devices must be temperature proof up to 90°C.
Do not operate the fixture with inductive consumers (fluorescent lamps, gas discharge lamps, ventilators etc.) in the same
electric circuit. Activation of inductive consumers can cause damage to the operating device.
Do not place heat insulation material on the fixture.
Mind the operating temperatures of the fixture according to the technical data sheet.
Before drilling the mounting holes, take precautions not to harm or damage any power lines.
Do not solder cable strands. Use cable strand sleeves instead.
Note and mind voltage label on the device.
Make sure flawless electrical connectivity is provided.;
Connecting the lamp to the powered-up mains can cause damage to the lamp! (voids product warranty!)
No modification allowed. No liability will be assumed in case of damage incurred by alteration, improper use or faulty installation.
2 | www.biontechnologies.com

Scope of delivery
Check completeness of supplied device immediately after receipt.
In delivery included:
1x User Manual
1x Luminaire Bion Technologies coma l
7x Lighting Connector (cETLus delivery only)
If you detect any transportation damage or differencies between specified packing contents and your unpacked delivery, please contact
your dealer immediately.
www.biontechnologies.com | 3

Technical Data
Dimensions 250 mm x 182 mm [L x D]
9.85 in x 7.17 in [L x D]
Fixture Typ
RGB RGBW
Color Temperatures W-Channel 2700 K, 3000 K, 4000 K
* Project-specific LED-colors for RGBW/RGB available.
Beam Angles 7°, 13°, 30°, 66°, 8° x 31°
11° x 45°, 12° x 60°, 20° x 60° (Tilt in C0-plane: 10°)
Luminous Flux 2036 lm
RGB 1641 lm
Light Source 24 LED(s)
Color Rendering Index Ra >= 80
LED-Binning
MacAdam Ellipses Binning 3
Control DMX
Input Voltage Power supply: internal | 100 - 240, 277 VAC (50 - 60 Hz) | 127 - 431 VDC
Power Consumption Max. 45 W
Power Factor Correction > 0,98 -> 115 VAC @ max. Output
> 0,95 -> 230 VAC @ max. Output
> 0,91 -> 277 VAC @ max. Output
Protection Class I
Inrush COLD START 55A@230VAC / 27A@110VAC (t width=265µs measured at 50% I peak)
Operating Temperature Range -20 °C / +40 °C | -4 °F / +104 °F
Lumen Maintenance [L70] 65’000 h @ 25 °C (77 °F) | 40‘000 h @ 40 °C (104 °F)
LED-Class Class 2 LED-Product
Housing Aluminium die casting
Housing Color(s)
White powd
ercoated
Black powd
ercoated
Lens Safety glass, printed
Weight 2,8 kg (6.17 lbs)
Ingress Protection IP65
Environment
indoor outdoor
4 | www.biontechnologies.com

Certification
Engineering Drawing
www.biontechnologies.com | 5

Load Table
Load Table 110 V
110 V B16 C16 D16 B32 C32
coma l 4 8 16 9 16
6 | www.biontechnologies.com

Mounting
1. Mounting
Pay attention to a solid condition of substrate where te fixture is mounted
Use appropriate screws, washer and anchors
www.biontechnologies.com | 7

Commissioning
1. Wiring CE - Version (Europe)
Before using the fixture, please remove the stick-on label on the illuminated surface.
If there are any unwanted flashes when operating the fixture, so the data line in accordance with the requirements of DMX512 plus and
minus the last light in each strand with a 120 ohm resistor is to be terminated.
CAUTION! – UNPLUG THE FIXTURE FROM THE MAINS POWER BEFORE CONNECTING ANY CABLES TO AVOID DAMAGING
THE PRODUCTS. DO NOT HOT SWAP FIXTURES
CAUTION! – AVOID STARING DIRECTLY INTO THE LED LIGHT SOURCE FOR YOUR OWN SAFETY.
2. Wiring cETLus - Version (North America)
Before using the fixture, please remove the stick-on label on the illuminated surface.
If there are any unwanted flashes while operating the fixture, so the data line is in accordance with the requirements of DMX512 DMX
plus and DMX minus the last fixture in each line with a 120 ohm resistor is to be terminated.
CAUTION! – UNPLUG THE FIXTURE FROM THE MAINS POWER BEFORE CONNECTING ANY CABLES TO AVOID DAMAGING
THE PRODUCTS. DO NOT HOT SWAP FIXTURES
CAUTION! – AVOID STARING DIRECTLY INTO THE LED LIGHT SOURCE FOR YOUR OWN SAFETY.
8 | www.biontechnologies.com

3. Cluster Wiring
4. Daisy Chain Wiring
www.biontechnologies.com | 9

5. Lock Screws
After installing the fixture and adjusting the angle for your lighting application you can use the lock screws to prevent the hinge from
moving.
Use a Torx 10 to screw and lock.
10 | www.biontechnologies.com