Let the control unit of the Automatic Granulate Feeder turned off.
Step 1: Check if the glue is completely melted. The sensor responses different
to solid or liquid glue.
Step 2: Place the sensor in the hole in the synthetic base.
Step 3: Make sure that 2 - 4 cm from the sensor is above the synthetic base.
(depends on type of tank and desired adhesive level).
Attach the washer to the sensor
Step 4: The adhesive level must be the same as ‘adhesive level 1’ as shown
in figure 4, so that the sensor is at least 40mm in the adhesive.
Step 5: Wait at least 5 minutes for the sensor to reach the adhesive temperature.
The range in the sensor is +/- 5mm from the bottom of the sensor, till +/-
20mm from the bottom of the sensor.
Continue with chapter 5.2 to calibrate the levelsensor.
5.2 Calibrate the levelsensor
Step 1: Switch dipswitch 1 to ON. The system is in ‘calibrate mode’.
Step 2: Close the control box and supply it with power.
Step 3: The led ‘hand’ flashes. Press button ‘hand’.
High level is now saved.
The led ‘auto’ starts to flash.
Step 4: Check the adhesive level in the tank, by removing the filltower.
Make sure that the AutoFill is voltage free.