BLIIoT RTU5028E Manuale utente

Network Fault Monitoring Alarm
RTU5028E
User Manual
Version:V1.1
Date:2020-01-07
Shenzhen Beilai Technology Co.,Ltd
Website:https://www.bliiot.com

Shenzhen Beilai Technology Co., Ltd V1.1
2
Network Fault Monitoring Alarm RTU5028E
Preface
Thanks for choosing BLIIoT Network Fault Monitoring Alarm. These operating
instructions contain all the information you need for operation of RTU5028E.
Copyright
This user manual is owned by Shenzhen Beilai Technology Co., Ltd. No one is
authorized to copy, distribute or forward any part of this document without written
approval of Shenzhen Beilai Technology. Any violation will be subject to legal liability.
Disclaimer
This document is designed for assisting user to better understand the device. As the
described device is under continuous improvement, this manual may be updated or
revised from time to time without prior notice. Please follow the instructions in the
manual. Any damages caused by wrong operation will be beyond warranty.
Revision History
Update Date
Version
Description
2019-07-01
V1.0
First Edition
2020-01-07
V1.1
Optimize configuration software
connection

Shenzhen Beilai Technology Co., Ltd V1.1
3
Network Fault Monitoring Alarm RTU5028E
Content
1 Product Introduction ...................................................................................................... 5
2 Safety Directions ............................................................................................................ 5
3 Packing List.....................................................................................................................6
4 Features .......................................................................................................................... 6
5 Technical Specifications ............................................................................................... 7
6 Hardware .........................................................................................................................7
6.1 LED Indicators .........................................................................................................7
6.2 Interface ................................................................................................................... 8
6.3 Switch&Button&SIM Card Slot ............................................................................. 8
7 Reset ................................................................................................................................9
8 Configuration Software ................................................................................................10
8.1 Search Device .......................................................................................................10
8.2 Selection .................................................................................................................11
8.3 Basic Settings ........................................................................................................11
8.4 Number Settings................................................................................................... 13
8.5 Alarm Settings ....................................................................................................... 14
8.6 Network Settings...................................................................................................15
8.7 Alarm Record .........................................................................................................17
9 SMS Command............................................................................................................ 18
9.1 Modify Password .................................................................................................. 18
9.2 Time Zone ..............................................................................................................18
9.3 Set the SIM Card Number ...................................................................................19
9.4 Set RTU5028E System Time ..............................................................................19
9.5 Inquiry Current Status ..........................................................................................20
9.6 Set Daily Report Time..........................................................................................20
9.7 Set Interval Report Time ......................................................................................20
9.8 Set Authorized User number...............................................................................21
9.9 Whether to Press * or # to End the Alarm .........................................................21

Shenzhen Beilai Technology Co., Ltd V1.1
4
Network Fault Monitoring Alarm RTU5028E
9.10 Set Voltage High and Low Limits..................................................................... 21
9.11 Set Alarm Confirmation Time............................................................................ 22
9.12 Set Alarm/Recovery SMS Content.................................................................. 22
9.13 Set Relay Output ................................................................................................ 23
9.14 Set PING Network Device IP............................................................................23
9.15 Set PING External Network IP or Domain Name .......................................... 23
9.16 Set Local Connection .........................................................................................24
9.17 Set Cellular Network Access Parameters .......................................................25
9.18 Enable/Disable Cellular Network ..................................................................... 25
9.19 Set Network Online............................................................................................ 25
9.20 Set Disconnection Reconnection Time ........................................................... 25
9.21 Set Register Package ........................................................................................25
9.22 Set Heartbeat Packet (For Modbus Protocol) ................................................26
9.23 Set Heartbeat Interval ........................................................................................26
9.24 Set Device ID ...................................................................................................... 26
9.25 Set Communication Protocol............................................................................26
9.26 Set Server Address............................................................................................ 27
9.27 Inquiry History Record....................................................................................... 27
9.28 Set Language ......................................................................................................27
9.29 Remote Restart Device..................................................................................... 28
9.30 Remote Factory Reset .......................................................................................28
10 Communication Protocol .......................................................................................... 28
10.1 Modbus Protocol .................................................................................................28
10.2 MQTT Protocol ....................................................................................................29
11 Warranty ......................................................................................................................32
12 Technical Support......................................................................................................32

Shenzhen Beilai Technology Co., Ltd V1.1
5
Network Fault Monitoring Alarm RTU5028E
1 Product Introduction
The Network Fault Monitoring RTU RTU5028E is special designed for remote
monitoring Ethernet devices communication status and power supply status. It can
detect the Ethernet device fault caused by power supply or network communication. If
network communication fault, it can remote or automatically restart the switch, Router
or device to solve issues, no need maintenance engineer to process, save time and
maintenance costs. Support monitoring up to 7 network devices simultaneously.
The configuration software can be connected via LAN, User-friendly configuration; It
also can be set and inquiry by SMS commands. Moreover, it also supports Modbus
RTU, Modbus TCP and MQTT protocol to connect to cloud Platform, automatic
switching to cellular network when the wired network failed, then monitor the current
status in real time through GSM/3G/4G network.
RTU5028E power failure and network fault monitoring alarm is suitable for classrooms,
public places, hospitals, stations, food warehouses, offices, factories, libraries,
laboratories, etc., and any place that requires and supports power and network
monitoring.
2 Safety Directions
Safe Startup
Do not use the unit when using 4G equipment is prohibited or might
bring disturbance or danger.
Interference
All wireless equipment might interfere network signals of the unit and
influence its performance.

Shenzhen Beilai Technology Co., Ltd V1.1
6
Network Fault Monitoring Alarm RTU5028E
3 Packing List
4 Features
Network failure + power failure + network cable monitoring, remote monitoring the
status of network device in many aspects;
Support monitoring up to 7 network devices simultaneously;
1 relay output for automatic restart or remote restart of network equipment;
Inbuilt MCU monitoring power supply input voltage value, measure range is
0~36V, no need additional sensor to save cost;
Up to 10 authorized phone numbers to receive specified alarm message;
Can set timer report and automatically send its status/value to the authorized
number;

Shenzhen Beilai Technology Co., Ltd V1.1
7
Network Fault Monitoring Alarm RTU5028E
Support remotely read 100 historic data via SMS or configuration software;
Support Modbus RTU, Modbus TCP and MQTT protocol, can be connected to
cloud platform;
GSM/GPRS/3G/4G/Ethernet network communication, automatic connect to
cellular network when wired network failed;
Rechargeable backup battery can last 2-3 hours;
Support wall-mounted and DIN35mm DIN rail installation.
5 Technical Specifications
6 Hardware
6.1 LED Indicators
Item
Parameters
Power supply
12VDC, support 9~36VDC
Power consumption
Standby: 100mA@12V; Max: 380mA@12V
Communication method
SMS, GPRS/3G/4G, Ethernet
Protocol
Modbus RTU Over TCP, Modbus TCP, MQTT
GSM/3G/4G
GSM: 850/900/1800/1900MHz
3G: 3G WCDMA
4G LTE: 4G LTE
Ethernet port
1xRJ45, support DHCP dynamic obtain IP or static
fixed IP
Relay output
1 NC relay output; 7A/125VAC, 5A/250VAC,
20A/14VDC
SIM slot
1.8V or 3.0V SIM card
Antenna
SMA antenna interface, 50ohm
Backup battery
3.7V/900mAh(Last 2~3 hours)
Working temperature
-10°C~60°C
Working humidity
95%(No condensation)
Dimension
70mm x 88mm x 30mm

Shenzhen Beilai Technology Co., Ltd V1.1
8
Network Fault Monitoring Alarm RTU5028E
LED Indicators
When 2G module signal is normal, it flashes slowly (flash every 2
seconds), and flashes quickly when there is no signal (flash every
0.8 seconds);
When the 3G/4G module signal is normal, the light turns off once
every 2 seconds, and when there is no signal, the light turns on
once every 2 seconds, and flashes continuously when transmitting
data
LED light ON when connect power, otherwise it is OFF
Light on when alarm occurs
Light on when relay open
6.2 Interface
Interface instruction
9~36V DC IN
+
DC9~36V positive input
–
DC9~36V negative input
Relay Output
Normally closed relay output, no polarity distinction
Ethernet
1 RJ45
ANT
GSM/3G/4G antenna interface
6.3 Switch&Button&SIM Card Slot
Please use a screwdriver to unscrew the screw of the small cover on the back of
device, and you can see the power switch, reset button (the button has two functions:
1. Upgrade: Press and hold the power on to enter the upgrade mode; 2. Reset: Power
on, press and hold for 3 seconds to reset) and the card slot (Chip faces down when

Shenzhen Beilai Technology Co., Ltd V1.1
9
Network Fault Monitoring Alarm RTU5028E
installing the SIM card).
7 Reset
1) Power on the device, press and hold the reset button for 3 seconds, and wait for
the power indicator to flash 3 times, indicating that the reset is successful.
2) Reset by SMS command "password+RESET", and return SMS "reset successful"
to indicate successful reset.

Shenzhen Beilai Technology Co., Ltd V1.1
10
Network Fault Monitoring Alarm RTU5028E
8 Configuration Software
When connecting to the configuration software for the first time, it is recommended to
connect the device to a router with the DHCP automatic IP assignment function; if the
network connected to the device cannot automatically assign IP, the device will use
the following default network parameters after connecting to the network cable and
waiting for 1 minute: IP address 192.168.1.111, subnet mask 255.255.255.0, and
gateway address 192.168.1.1. At this time, please set the computer network
parameters to other IP addresses in the same network segment to connect; if the
device is directly connected to the computer, please use a crossover cable to connect,
and please configure the computer network parameters before connecting the device.
8.1 Search Device
【Search Device】Search all devices in the current LAN. Computer and the device
must be in the same network segment, and the subnet mask must be 255.255.255.0
【Enter】Enter the configuration interface of corresponding device
【Language】Change language
Note: If the device cannot be found, but the fixed IP of the device has been set, you
can directly enter the fixed IP of the device in the IP input field.
Indice
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente